Abstract
The common mode voltage (CMV) causes many issues and negatively affects the performance of the power system in a hybrid electric vehicle HEV. Therefore, this paper suggests a simple method for mitigating the common mode voltage CMV in a two level three phase voltage source inverter VSI with RL load. Hence, the technique chosen for this purpose is based on model predictive control. Otherwise, when compared to the standard method, this simple method can successfully mitigate CMV while also improving harmonic performance by lowering the total harmonic distortion THD. The purpose of this paper is reducing THD and CMV simultaneously utilizing only non-zero vectors. According to simulation results obtained by MATLAB-Simulink, this simple solution reduced CMV to ±𝑉𝑑𝑐 6 and THD from 3.49% to 3.39 % (10 % improvement) compared with the standard method, which mitigates CMV using the cost function.
Collaboration network of the authors
3 authors ·
3 co-authorship links
Hover or tap a name to highlight its co-authors. Double-click to open the author's page.
Université des Sciences et de la Technologie d'Oran Mohamed Boudiaf
Different organisations
Same organisation
Affiliation unknown
Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-author Organisation Joint articles
Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.
Metadata source: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, first harvested 8 Nov 2026, last seen 29 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">Simple finite-control-set model predictive control method for reducing common mode voltage in a three phase two-level voltage source inverter</dc:title>
<dc:creator>Abdelaziz, Fatima</dc:creator>
<dc:creator>Azzouz, Zin-Eddine</dc:creator>
<dc:creator>Omari, Abdelhafid</dc:creator>
<dc:subject xml:lang="en-US">Common mode voltage; Hybrid electric vehicle; Model predictive control; Total harmonic distortion; Voltage source inverter</dc:subject>
<dc:description xml:lang="en-US">The common mode voltage (CMV) causes many issues and negatively affects the performance of the power system in a hybrid electric vehicle HEV. Therefore, this paper suggests a simple method for mitigating the common mode voltage CMV in a two level three phase voltage source inverter VSI with RL load. Hence, the technique chosen for this purpose is based on model predictive control. Otherwise, when compared to the standard method, this simple method can successfully mitigate CMV while also improving harmonic performance by lowering the total harmonic distortion THD. The purpose of this paper is reducing THD and CMV simultaneously utilizing only non-zero vectors. According to simulation results obtained by MATLAB-Simulink, this simple solution reduced CMV to ±𝑉𝑑𝑐 6 and THD from 3.49% to 3.39 % (10 % improvement) compared with the standard method, which mitigates CMV using the cost function.</dc:description>
<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
<dc:contributor xml:lang="en-US"></dc:contributor>
<dc:date>2022-09-01</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:type xml:lang="en-US"></dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/21710</dc:identifier>
<dc:identifier>10.11591/ijpeds.v13.i3.pp1904-1911</dc:identifier>
<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 13, No 3: September 2022; 1904-1911</dc:source>
<dc:source>2722-256X</dc:source>
<dc:source>2088-8694</dc:source>
<dc:source>10.11591/ijpeds.v13.i3</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/21710/13944</dc:relation>
<dc:rights xml:lang="en-US">Copyright (c) 2022 Fatima Abdelaziz, Zin-Eddine Azzouz, Abdelhafid Omari</dc:rights>
<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>
Citations and indexing
OpenAlex
Indexed
via DOI
3 citations
Crossref
Indexed
via DOI
2 citations
Counts as reported by each index on 13 Nov 2026; indexes count citations differently.
OpenAlex also lists this work in: crossref.
Cite this article
APA 7
Abdelaziz, F., Azzouz, Z. E., & Omari, A. (2022). Simple finite-control-set model predictive control method for reducing common mode voltage in a three phase two-level voltage source inverter. International Journal of Power Electronics and Drive Systems, 13(3), 1904–1911. https://doi.org/10.11591/ijpeds.v13.i3.pp1904-1911
Copy
IEEE
F. Abdelaziz, Z. E. Azzouz, and A. Omari, “Simple finite-control-set model predictive control method for reducing common mode voltage in a three phase two-level voltage source inverter,” International Journal of Power Electronics and Drive Systems, vol. 13, no. 3, pp. 1904–1911, 2022, doi: 10.11591/ijpeds.v13.i3.pp1904-1911.
Copy
Generated from the journal's metadata; check author names before use.