Harmonic Elimination Using STATCOM for SEIG Fed Induction Motor Load

International Journal of Power Electronics and Drive Systems · Vol. 8 No. 3 (2017) · pp. 1026–1034

DOI
10.11591/ijpeds.v8.i3.pp1026-1034
ISSN
2722-256X, 2088-8694
Published
2017-09-01
Publisher
Institute of Advanced Engineering and Science
Language
eng
License
creativecommons.org/licenses/by-sa/4.0

Abstract

Non-linear loads connected to distribution system induce harmonics in to source components and the presence of harmonics in source components affects the performance of other sensitive loads connected at the same point. Induction motor load for drive system should be operated with variable frequency and variable voltage for its speed control. To vary the voltage and frequency, induction motor is fed from an inverter. This total drive set-up constitutes non-linear load type and will be the source of harmonics. This paper depicts the suppression of harmonics with STATCOM in distribution system when induction motor load is fed from SEIG (singly excited inductin generator). STATCOM is controlled with simple synchronous reference frame theory and the results are shown for source current, load current. THD in source current and load current was also shown for the said system. System for single-phase and three-phase induction motor drive was developed and results are shown using MATLAB/SIMULINK software.

Collaboration network of the authors

4 authors · 4 co-authorship links

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Koneru Lakshmaiah Education Foundation
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
S. V. N. L. LalithaKoneru Lakshmaiah Education Foundation1
Savarapu Chandra SekharKoneru Lakshmaiah Education Foundation1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, first harvested 8 Nov 2026, last seen 16 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Harmonic Elimination Using STATCOM for SEIG Fed Induction Motor Load</dc:title>
	<dc:creator>Gorantla, Satyanarayana</dc:creator>
	<dc:creator>Ravi Kumar, Goli</dc:creator>
	<dc:description xml:lang="en-US">Non-linear loads connected to distribution system induce harmonics in to source components and the presence of harmonics in source components affects the performance of other sensitive loads connected at the same point. Induction motor load for drive system should be operated with variable frequency and variable voltage for its speed control. To vary the voltage and frequency, induction motor is fed from an inverter. This total drive set-up constitutes non-linear load type and will be the source of harmonics. This paper depicts the suppression of harmonics with STATCOM in distribution system when induction motor load is fed from SEIG (singly excited inductin generator). STATCOM is controlled with simple synchronous reference frame theory and the results are shown for source current, load current. THD in source current and load current was also shown for the said system. System for single-phase and three-phase induction motor drive was developed and results are shown using MATLAB/SIMULINK software.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2017-09-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/8077</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v8.i3.pp1026-1034</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 8, No 3: September 2017; 1026-1034</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v8.i3</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/8077/7000</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2017 Satyanarayana Gorantla, Goli Ravi Kumar</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>