Melola Discovery

← Melola Discovery

Open access Journal SINTA 1

Comparative simulation of fractional-order PD sliding mode and fuzzy logic controllers for a second-order discrete-time nonlinear system

International Journal of Power Electronics and Drive Systems · Vol. 17 No. 3 (2026) · pp. 1822–1830

DOI
10.11591/ijpeds.v17.i3.pp1822-1830
ISSN
2722-256X, 2088-8694
Published
2026-09-01
Publisher
Institute of Advanced Engineering and Science
Language
eng
License
creativecommons.org/licenses/by-sa/4.0

Abstract

Tight output regulation in power converters and electric drive systems requires a control strategy that simultaneously minimizes tracking error and maintains smooth actuation-two objectives that are intrinsically in tension for nonlinear, parameter-varying plants. Despite the widespread deployment of fractional-order PD sliding mode control (FOPD-SMC) and Mamdani fuzzy logic control (FLC) in this domain, no prior study has placed them in a direct, metric-identical comparison on a common plant. The present work closes this gap by implementing both controllers on the same second-order discrete-time nonlinear plant-representative of DC-DC converter output dynamics and motor-drive input-output behavior and evaluating them under a composite reference that combines sinusoidally-modulated ramps with step transitions, scored by the integral of squared error (ISE) and integral of absolute error (IAE). FOPD-SMC achieves ISE= 1.639 × 10-2 and IAE= 3.345 × 10-2, outperforming FLC by 87.6% and 50.4%, respectively; the advantage originates from the non-integer memory embedded in the sliding surface via the Gr¨unwald-Letnikov operator and from the explicit decomposition of the control law into nominal-tracking and robustness components. FLC, conversely, produces a chattering-free, continuously varying control signal a structural consequence of smooth Gaussian membership functions and linguistic rule aggregation, at the cost of a mean absolute tracking error twice that of FOPD-SMC. These findings establish a quantitative selection criterion: FOPD-SMC is recommended when tight voltage or current regulation is the primary objective, while FLC is preferred where smooth torque delivery and reduced actuator stress outweigh marginal gains in tracking accuracy.

Keywords

Collaboration network of the authors

7 authors · 12 co-authorship links · 8 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Amar Telidji University of Laghouat
  • University Center of Aflou
  • Umm al-Qura University
  • University Yahia Fares of Medea
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Mohammed MekhanetAmar Telidji University of Laghouat1
Lakhdar MokraniAmar Telidji University of Laghouat1
Yacine AttiaUniversity Yahia Fares of Medea1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, first harvested 8 Nov 2026, last seen 22 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Comparative simulation of fractional-order PD sliding mode and fuzzy logic controllers for a second-order discrete-time nonlinear system</dc:title>
	<dc:creator>Bennaoui, Ahmed</dc:creator>
	<dc:creator>Benzian, Salah</dc:creator>
	<dc:creator>Sulimani, Hamza</dc:creator>
	<dc:creator>Ameur, Aissa</dc:creator>
	<dc:subject xml:lang="en-US">fractional-order control; Fuzzy logic control; nonlinear systems; power electronics and drive systems; sliding mode control</dc:subject>
	<dc:description xml:lang="en-US">Tight output regulation in power converters and electric drive systems requires a control strategy that simultaneously minimizes tracking error and maintains smooth actuation-two objectives that are intrinsically in tension for nonlinear, parameter-varying plants. Despite the widespread deployment of fractional-order PD sliding mode control (FOPD-SMC) and Mamdani fuzzy logic control (FLC) in this domain, no prior study has placed them in a direct, metric-identical comparison on a common plant. The present work closes this gap by implementing both controllers on the same second-order discrete-time nonlinear plant-representative of DC-DC converter output dynamics and motor-drive input-output behavior and evaluating them under a composite reference that combines sinusoidally-modulated ramps with step transitions, scored by the integral of squared error (ISE) and integral of absolute error (IAE). FOPD-SMC achieves ISE= 1.639 × 10-2 and IAE= 3.345 × 10-2, outperforming FLC by 87.6% and 50.4%, respectively; the advantage originates from the non-integer memory embedded in the sliding surface via the Gr¨unwald-Letnikov operator and from the explicit decomposition of the control law into nominal-tracking and robustness components. FLC, conversely, produces a chattering-free, continuously varying control signal a structural consequence of smooth Gaussian membership functions and linguistic rule aggregation, at the cost of a mean absolute tracking error twice that of FOPD-SMC. These findings establish a quantitative selection criterion: FOPD-SMC is recommended when tight voltage or current regulation is the primary objective, while FLC is preferred where smooth torque delivery and reduced actuator stress outweigh marginal gains in tracking accuracy.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2026-09-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/24551</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v17.i3.pp1822-1830</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 17, No 3: September 2026; 1822-1830</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v17.i3</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/24551/15314</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2026 Ahmed Bennaoui, Salah Benzian, Hamza Sulimani, Aissa Ameur</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>