Modified instantaneous power theory control of dynamic voltage restorer powered by photovoltaic system

International Journal of Power Electronics and Drive Systems · Vol. 14 No. 4 (2023) · pp. 2418–2432

DOI
10.11591/ijpeds.v14.i4.pp2418-2432
ISSN
2722-256X, 2088-8694
Published
2023-12-01
Publisher
Institute of Advanced Engineering and Science
Language
eng
License
creativecommons.org/licenses/by-sa/4.0

Abstract

Power quality issues have become widespread due to nonlinear electronic converters and loads. Nonlinear components in the power system hamper the power quality, network efficiency and voltage regulation. The power quality issues like sag, swell, and voltage unbalance can be reduced by employing a dynamic voltage restorer (DVR). DVR provides the compensating power from a DC source to minimize the effect of sag, swell, and voltage unbalance. This article presents a power system with DVR using a photovoltaic system (PV) as a DC source instead of a conventional battery source. This article proposes a modified instantaneous power (PQ) control technique to generate the reference signal of load voltage to assure the DVR's superior performance. This modified technique uses an anti-aliasing filter to generate a reference signal. This proposed technique is tested under extreme power quality issues of 80% sag, 20% sag, 120% swell, 170% swell, and voltage unbalance. The DVR is modeled and simulated using MATLAB/Simulink. A comparison is made between the traditional and modified PQ methods from the obtained results. The analyzed results under severe power quality issues suggest that the proposed P-Q control technique is a preferable option for the DVR with PV as a DC power supply.

Keywords

Collaboration network of the authors

7 authors · 13 co-authorship links · 8 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • King Khalid University
  • Annamalai University
  • SRKR Engineering College
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Majahar Hussain MahammadKing Khalid University1
Venkata Krishna BokkaAnnamalai University1
E. R. BijuAnnamalai University1
Sai Veerraju MorthaSRKR Engineering College1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, first harvested 8 Nov 2026, last seen 29 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Modified instantaneous power theory control of dynamic voltage restorer powered by photovoltaic system</dc:title>
	<dc:creator>Asiri, Yousef</dc:creator>
	<dc:creator>Al-Gahtani, Saad F.</dc:creator>
	<dc:creator>Irshad, Shaik Mohammad</dc:creator>
	<dc:subject xml:lang="en-US">DVR; power quality; PQ control; sag; swell</dc:subject>
	<dc:description xml:lang="en-US">Power quality issues have become widespread due to nonlinear electronic converters and loads. Nonlinear components in the power system hamper the power quality, network efficiency and voltage regulation. The power quality issues like sag, swell, and voltage unbalance can be reduced by employing a dynamic voltage restorer (DVR). DVR provides the compensating power from a DC source to minimize the effect of sag, swell, and voltage unbalance. This article presents a power system with DVR using a photovoltaic system (PV) as a DC source instead of a conventional battery source. This article proposes a modified instantaneous power (PQ) control technique to generate the reference signal of load voltage to assure the DVR's superior performance. This modified technique uses an anti-aliasing filter to generate a reference signal. This proposed technique is tested under extreme power quality issues of 80% sag, 20% sag, 120% swell, 170% swell, and voltage unbalance. The DVR is modeled and simulated using MATLAB/Simulink. A comparison is made between the traditional and modified PQ methods from the obtained results. The analyzed results under severe power quality issues suggest that the proposed P-Q control technique is a preferable option for the DVR with PV as a DC power supply.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US">King Khalid University</dc:contributor>
	<dc:date>2023-12-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/22823</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v14.i4.pp2418-2432</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 14, No 4: December 2023; 2418-2432</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v14.i4</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/22823/14375</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2023 Shaik Mohammad Irshad</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>