Melola Discovery

← Melola Discovery

Open access Journal SINTA 1

A flexible islanding identification technique for PV based grid-tied systems

International Journal of Power Electronics and Drive Systems · Vol. 15 No. 1 (2024) · pp. 180–191

DOI
10.11591/ijpeds.v15.i1.pp180-191
ISSN
2722-256X, 2088-8694
Published
2024-03-01
Publisher
Institute of Advanced Engineering and Science
Language
eng
License
creativecommons.org/licenses/by-sa/4.0

Abstract

The phenomenon of islanding, which occurs in grid integrated distributed generators (DGs), poses significant challenges and potential risks for customers, utility providers, and operational personnel. Detecting islanding quickly and accurately is crucial. The issues related to the conventional islanding methods paved the way in developing a hybrid islanding identification scheme. The developed method achieves accurate results within a reduced time span of 30 ms. The hybrid technique combines the passive method of sliding window based moving average (SWMA) for faster detection and the active method of asymmetrical bilateral reactive power perturbation (ABRPP) for improved precision. The developed hybrid method is simulated and tested using MATLAB/Simulink 2023a. It undergoes testing under various load conditions, including small and large power mismatches between DG generation and local load demand, as well as different load quality factors (QF). Additionally, the hybrid algorithm demonstrates no nuisance tripping when subjected to different load switching conditions such as capacitor switching, motor load switching, and nonlinear load switching. A comparison with existing islanding detection methods confirms the accuracy and speed of the proposed method in identifying islanding conditions.

Keywords

Collaboration network of the authors

2 authors · 1 co-authorship link

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, first harvested 8 Nov 2026, last seen 22 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">A flexible islanding identification technique for PV based  grid-tied systems</dc:title>
	<dc:creator>Sarojam, Praveen Raj Rajaswamy</dc:creator>
	<dc:creator>Savier, Joseph Sarojini</dc:creator>
	<dc:subject xml:lang="en-US">ABRPP;  grid integration; hybrid islanding identification scheme; mon-detection zone; quality factor; SWMA</dc:subject>
	<dc:description xml:lang="en-US">The phenomenon of islanding, which occurs in grid integrated distributed generators (DGs), poses significant challenges and potential risks for customers, utility providers, and operational personnel. Detecting islanding quickly and accurately is crucial. The issues related to the conventional islanding methods paved the way in developing a hybrid islanding identification scheme. The developed method achieves accurate results within a reduced time span of 30 ms. The hybrid technique combines the passive method of sliding window based moving average (SWMA) for faster detection and the active method of asymmetrical bilateral reactive power perturbation (ABRPP) for improved precision. The developed hybrid method is simulated and tested using MATLAB/Simulink 2023a. It undergoes testing under various load conditions, including small and large power mismatches between DG generation and local load demand, as well as different load quality factors (QF). Additionally, the hybrid algorithm demonstrates no nuisance tripping when subjected to different load switching conditions such as capacitor switching, motor load switching, and nonlinear load switching. A comparison with existing islanding detection methods confirms the accuracy and speed of the proposed method in identifying islanding conditions.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2024-03-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/22975</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v15.i1.pp180-191</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 15, No 1: March 2024; 180-191</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v15.i1</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/22975/14414</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2023 Praveen Raj, Savier JS</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>