Open access
Journal
SINTA 1
Thermodynamic analysis of a thermoelectric air conditioner
International Journal of Power Electronics and Drive Systems · Vol. 13 No. 3 (2022) · pp. 1568–1575
ISSN 2722-256X, 2088-8694
Published 2022-09-01
Publisher Institute of Advanced Engineering and Science
Language eng
Abstract
This paper discusses the results of tests done to investigate the performance of a thermoelectric air conditioner (TEAC). The TEAC is composed of twelve thermoelectric modules (TEMs). The TEMs were fixed to rectangular fin heat sinks on both their hot and cold sides. With an increased input voltage, the cooling capacity increased. At a 6 V input voltage flow, a suitable condition occurred. The rate of hot air flow was 0.48 kg/min, and the cooling capacity was 157.0 W, resulting in an outlet air temperature of 28 oC. The coefficient of performance (COP) was calculated and found to be 0.92. Exergy analysis is used to determine the energy flows and second law efficiencies of a TEMs system and its components. The exergy destruction and second law efficiency were observed to increase when the TEAC's input voltage was increased. The TEAC's maximum exergy efficiency was 0.35, which was low compared to the coefficient of performance.
Collaboration network of the authors
8 authors ·
14 co-authorship links
· 3 across different organisations
Hover or tap a name to highlight its co-authors. Double-click to open the author's page.
Naresuan University King Mongkut's University of Technology Thonburi
Different organisations
Same organisation
Affiliation unknown
Thicker line = more joint articles · bigger circle = more articles
Show as table
Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.
Metadata source: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, first harvested 8 Nov 2026, last seen 29 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">Thermodynamic analysis of a thermoelectric air conditioner</dc:title>
<dc:creator>Channoy, Chanchira</dc:creator>
<dc:creator>Maneewan, Somchai</dc:creator>
<dc:creator>Punlek, Chantana</dc:creator>
<dc:subject xml:lang="en-US">Coefficient of performance; Cooling capacity; Exergy; Thermoelectric; Thermoelectric air conditioner</dc:subject>
<dc:description xml:lang="en-US">This paper discusses the results of tests done to investigate the performance of a thermoelectric air conditioner (TEAC). The TEAC is composed of twelve thermoelectric modules (TEMs). The TEMs were fixed to rectangular fin heat sinks on both their hot and cold sides. With an increased input voltage, the cooling capacity increased. At a 6 V input voltage flow, a suitable condition occurred. The rate of hot air flow was 0.48 kg/min, and the cooling capacity was 157.0 W, resulting in an outlet air temperature of 28 oC. The coefficient of performance (COP) was calculated and found to be 0.92. Exergy analysis is used to determine the energy flows and second law efficiencies of a TEMs system and its components. The exergy destruction and second law efficiency were observed to increase when the TEAC's input voltage was increased. The TEAC's maximum exergy efficiency was 0.35, which was low compared to the coefficient of performance.</dc:description>
<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
<dc:contributor xml:lang="en-US">The International Research Network Program (IRN) NO. IRN5703PHDW01, The Thailand Research Fund (TRF).</dc:contributor>
<dc:date>2022-09-01</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:type xml:lang="en-US"></dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/21840</dc:identifier>
<dc:identifier>10.11591/ijpeds.v13.i3.pp1568-1575</dc:identifier>
<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 13, No 3: September 2022; 1568-1575</dc:source>
<dc:source>2722-256X</dc:source>
<dc:source>2088-8694</dc:source>
<dc:source>10.11591/ijpeds.v13.i3</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/21840/13959</dc:relation>
<dc:rights xml:lang="en-US">Copyright (c) 2022 Chanchira Channoy, Somchai Maneewan, Chantana Punlek</dc:rights>
<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>
Citations and indexing
OpenAlex
Indexed
via DOI
1 citation
Crossref
Indexed
via DOI
0 citations
Counts as reported by each index on 13 Nov 2026; indexes count citations differently.
OpenAlex also lists this work in: crossref.
Cite this article
APA 7
Channoy, C., Maneewan, S., & Punlek, C. (2022). Thermodynamic analysis of a thermoelectric air conditioner. International Journal of Power Electronics and Drive Systems, 13(3), 1568–1575. https://doi.org/10.11591/ijpeds.v13.i3.pp1568-1575
Copy
IEEE
C. Channoy, S. Maneewan, and C. Punlek, “Thermodynamic analysis of a thermoelectric air conditioner,” International Journal of Power Electronics and Drive Systems, vol. 13, no. 3, pp. 1568–1575, 2022, doi: 10.11591/ijpeds.v13.i3.pp1568-1575.
Copy