Abstract

This paper provides the results of a concerted investigation into developing a robust voltage controller for the modular multilevel converter (MMC) used in the D-STATCOM. The simplicity of the half bridge (HB) sub-module, along with the fact that it has minimal conduction losses, led to its adoption in the MMC. For the purpose of controlling the HB MMC switches, an enhanced modulation strategy based on the phase disposition (PD) scheme has been implemented. In the presence of nonlinear load conditions, the converters are experiencing difficulties with the DC voltage balancing. The sliding mode controller (SMC) is utilized so that the DC voltage can be maintained in a balanced state. Performance characteristics including active power, reactive power, dc voltage control and THD are shown and compared. For the purpose of simulating the indicated methodology, MATLAB/Simulink is the tool of choice.

Keywords

Collaboration network of the authors

12 authors · 17 co-authorship links · 1 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Jawaharlal Nehru Technological University Anantapur
  • R.V. College of Engineering
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Syed SurayaJawaharlal Nehru Technological University Anantapur2
N. ChaitanyaAffiliation unknown1
Koritala Chandra SekharR.V. College of Engineering1
P. Bharat KumarAffiliation unknown1
Mallempati Sunil KumarJawaharlal Nehru Technological University Anantapur1
G. SatheeshJawaharlal Nehru Technological University Anantapur1
Gopisetti SateeshAffiliation unknown1
Meesala VenkateswarluJawaharlal Nehru Technological University Anantapur1
P. KumarJawaharlal Nehru Technological University Anantapur1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, first harvested 8 Nov 2026, last seen 22 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Enactment of HBMMC five-level inverter based D-STATCOM using robust controllers</dc:title>
	<dc:creator>Ramakrishna, Elluru</dc:creator>
	<dc:creator>Jayakrishna, Gadhamappagari</dc:creator>
	<dc:creator>Peddakotla, Sujatha</dc:creator>
	<dc:subject xml:lang="en-US">DC voltage balance; half bridge sub module; modular multilevel converter; phase disposition; PI controller</dc:subject>
	<dc:description xml:lang="en-US">This paper provides the results of a concerted investigation into developing a robust voltage controller for the modular multilevel converter (MMC) used in the D-STATCOM. The simplicity of the half bridge (HB) sub-module, along with the fact that it has minimal conduction losses, led to its adoption in the MMC. For the purpose of controlling the HB MMC switches, an enhanced modulation strategy based on the phase disposition (PD) scheme has been implemented. In the presence of nonlinear load conditions, the converters are experiencing difficulties with the DC voltage balancing. The sliding mode controller (SMC) is utilized so that the DC voltage can be maintained in a balanced state. Performance characteristics including active power, reactive power, dc voltage control and THD are shown and compared. For the purpose of simulating the indicated methodology, MATLAB/Simulink is the tool of choice.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2024-06-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/23043</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v15.i2.pp1001-1008</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 15, No 2: June 2024; 1001-1008</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v15.i2</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/23043/14516</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2024 Elluru Ramakrishna</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>