Melola Discovery

← Melola Discovery

Journal SINTA 1

Determining X-Ray Effective Energy in Linear Accelerator (LINAC) Radiotherapy Instrument

JURNAL ILMIAH PENDIDIKAN FISIKA AL BIRUNI · Vol. 7 No. 1 (2018) · pp. 99–104

DOI
10.24042/jipfalbiruni.v7i1.2336
ISSN
2503-023X, 2303-1832
Published
2018-04-28
Publisher
Universitas Islam Negeri Raden Intan Lampung, Indonesia
Language
eng

Abstract

This research in determining x-ray effective energy in linear accelerator (Linac) radiotherapy device was done using copper plates at different thicknesses by determining the Half Value Layer (HVL) for each energy. The purpose of this research is to know the amount of effective energy used in radiotherapy linear accelerator. The results showed that the energy of 6 MeV obtained 2,714 MeV of effective energy at HVL 4,500 mm and at the energy of 10 MeV obtained 4,231 MeV of effective energy at HVL 4,500 mm.

Keywords

Collaboration network of the authors

11 authors · 14 co-authorship links · 4 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Hasanuddin University
  • University of Mataram
  • Universitas Syiah Kuala
  • National Research and Innovation Agency
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Hermansyah HermansyahUniversity of Mataram1
Abdul Hadi MahmudAffiliation unknown1
Widya SariUniversitas Syiah Kuala1
Ashvia Nur IlyosaAffiliation unknown1
Nurbayani NurbayaniAffiliation unknown1
Nurbayani AliAffiliation unknown1
Maimun SariAffiliation unknown1
Nurjannah NurjannahHasanuddin University1
Yuliati HerbaniNational Research and Innovation Agency1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OAI-PMH (metadata jurnal) http://ejournal.radenintan.ac.id/index.php/al-biruni/oai, first harvested 9 Nov 2026, last seen 22 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">Determining X-Ray Effective Energy in Linear Accelerator (LINAC) Radiotherapy Instrument</dc:title>
	<dc:creator xml:lang="en">Fauziah, Fauziah</dc:creator>
	<dc:creator xml:lang="en">Abdullah, Bualkar</dc:creator>
	<dc:subject xml:lang="en">copper plates</dc:subject>
	<dc:subject xml:lang="en">effective energy</dc:subject>
	<dc:subject xml:lang="en">half value layer</dc:subject>
	<dc:subject xml:lang="en">linear accelerator</dc:subject>
	<dc:description xml:lang="en">This research in determining x-ray effective energy in linear accelerator (Linac) radiotherapy device was done using copper plates at different thicknesses by determining the Half Value Layer (HVL) for each energy. The purpose of this research is to know the amount of effective energy used in radiotherapy linear accelerator. The results showed that the energy of 6 MeV obtained 2,714 MeV of effective energy at HVL 4,500 mm and at the energy of 10 MeV obtained 4,231 MeV of effective energy at HVL 4,500 mm.</dc:description>
	<dc:publisher xml:lang="en">Universitas Islam Negeri Raden Intan Lampung, Indonesia</dc:publisher>
	<dc:date>2018-04-28</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:format>application/msword</dc:format>
	<dc:identifier>https://ejournal.radenintan.ac.id/index.php/al-biruni/article/view/2336</dc:identifier>
	<dc:identifier>10.24042/jipfalbiruni.v7i1.2336</dc:identifier>
	<dc:source xml:lang="en">Jurnal Ilmiah Pendidikan Fisika Al-Biruni; Vol. 7 No. 1 (2018): Jurnal Ilmiah Pendidikan Fisika Al-Biruni; 99-104</dc:source>
	<dc:source xml:lang="id">Jurnal Ilmiah Pendidikan Fisika Al-Biruni; Vol 7 No 1 (2018): Jurnal Ilmiah Pendidikan Fisika Al-Biruni; 99-104</dc:source>
	<dc:source>2503-023X</dc:source>
	<dc:source>2303-1832</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ejournal.radenintan.ac.id/index.php/al-biruni/article/view/2336/pdf</dc:relation>
	<dc:relation>https://ejournal.radenintan.ac.id/index.php/al-biruni/article/view/2336/8256</dc:relation>
	<dc:rights xml:lang="en">Copyright (c) 2018 Jurnal Ilmiah Pendidikan Fisika Al-Biruni</dc:rights>
</oai_dc:dc>