Melola Discovery

← Melola Discovery

Journal SINTA 1

Finite Element Analysis of Miniplate for Post-Fracture Finger Rehabilitation Device

Journal of Applied Engineering and Technological Science (JAETS) · Vol. 2 No. 1 (2020) · pp. 21–26

DOI
10.37385/jaets.v2i1.160
ISSN
2715-6079, 2715-6087
Published
2020-11-11
Publisher
Yayasan Riset dan Pengembangan Intelektual (YRPI)
Language
en

Abstract

Miniplate plays an important role as one of the implant components used as a rehabilitation device for a post-fracture finger. In this study, an analysis was carried out to determine the strength of the miniplate design made from Ti-6Al-4V titanium alloy material. Simulation and analysis were carried out using the finite element method. The given input for modeling tensile and bending loads determined von Mises stress, kinetic energy, strain energy, and internal energy. The analysis showed that uneven von Mises stress and strain distribution have occurred. The critical concentration of stresses was located at the center of the miniplate and these values were a lot lower than the yield stress of Ti-6Al-4V.

Keywords

Collaboration network of the authors

39 authors · 121 co-authorship links · 10 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • UIN Sunan Ampel Surabaya
  • Institut Agama Islam Negeri Kendari
  • Universitas KH. A. Wahab Hasbullah
  • Meteorological, Climatological, And Geophysical Agency
  • Universitas Muhammadiyah Parepare
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
AM MufarrihAffiliation unknown9
A. Hanif FirdausAffiliation unknown4
Fina Andika F. A.Affiliation unknown4
Andre KurniawanAffiliation unknown3
Zakki Fuadi EmzainAffiliation unknown3
Moh HartonoAffiliation unknown2
Moh. Nasir HariyantoAffiliation unknown2
Fataa KusumattaqiinAffiliation unknown2
Rangga E. SantosoAffiliation unknown2
Finsa Adhi PratamaInstitut Agama Islam Negeri Kendari1
Aris Nur Qadar Ar RazakInstitut Agama Islam Negeri Kendari1
Habibullah HabibullahAffiliation unknown1
Muh Asrianto ZainalInstitut Agama Islam Negeri Kendari1
La Ode Muhammad Iman Abdi Anantomo UkeInstitut Agama Islam Negeri Kendari1
Dian Candra Rini NovitasariUIN Sunan Ampel Surabaya1
Fajar SetiawanMeteorological, Climatological, And Geophysical Agency1
Risma Madurahma PutriUIN Sunan Ampel Surabaya1
Ahmad Hanif AsyharUIN Sunan Ampel Surabaya1
Nurissaidah UlinnuhaUIN Sunan Ampel Surabaya1
Elisa SyafaqohAffiliation unknown1
Yusuf Dewantoro HerlambangAffiliation unknown1
Nanang ApriandiAffiliation unknown1
Avicenna An-NizhamiAffiliation unknown1
Bono BonoAffiliation unknown1
Friska Ayu Fitrianti SugionoAffiliation unknown1
Ignatius Gunawan WidodoAffiliation unknown1
Padang YanuarAffiliation unknown1
Poppy PuspitasariAffiliation unknown1
Putut MurdantoAffiliation unknown1
Mohammad HartonoAffiliation unknown1
Syamsul HadiAffiliation unknown1
Jasman JasmanUniversitas Muhammadiyah Parepare1
Remon LapisaAffiliation unknown1
Zainal AbadiAffiliation unknown1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OAI-PMH (metadata jurnal) https://journal.yrpipku.com/index.php/jaets/oai, first harvested 9 Nov 2026, last seen 9 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">Finite Element Analysis of Miniplate for Post-Fracture Finger Rehabilitation Device </dc:title>
	<dc:creator xml:lang="en">Qosim, Nanang</dc:creator>
	<dc:creator xml:lang="en">Monasari, Ratna</dc:creator>
	<dc:creator xml:lang="en">Emzain, Zakki F.</dc:creator>
	<dc:creator xml:lang="en">Hakim, Lutfi</dc:creator>
	<dc:creator xml:lang="en">Sai’in, Ali</dc:creator>
	<dc:subject xml:lang="en">miniplate; implant; finite elemen method; fracture; finger; titanium.</dc:subject>
	<dc:description xml:lang="en">Miniplate plays an important role as one of the implant components used as a rehabilitation device for a post-fracture finger. In this study, an analysis was carried out to determine the strength of the miniplate design made from Ti-6Al-4V titanium alloy material. Simulation and analysis were carried out using the finite element method. The given input for modeling tensile and bending loads determined von Mises stress, kinetic energy, strain energy, and internal energy. The analysis showed that uneven von Mises stress and strain distribution have occurred. The critical concentration of stresses was located at the center of the miniplate and these values were a lot lower than the yield stress of Ti-6Al-4V.</dc:description>
	<dc:publisher xml:lang="en">Yayasan Riset dan Pengembangan Intelektual (YRPI)</dc:publisher>
	<dc:date>2020-11-11</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journal.yrpipku.com/index.php/jaets/article/view/160</dc:identifier>
	<dc:identifier>10.37385/jaets.v2i1.160</dc:identifier>
	<dc:source xml:lang="en">Journal of Applied Engineering and Technological Science (JAETS); Vol. 2 No. 1 (2020): Journal of Applied Engineering and Technological Science (JAETS); 21-26</dc:source>
	<dc:source>2715-6079</dc:source>
	<dc:source>2715-6087</dc:source>
	<dc:source>10.37385/jaets.v2i1</dc:source>
	<dc:language>en</dc:language>
	<dc:relation>https://journal.yrpipku.com/index.php/jaets/article/view/160/120</dc:relation>
	<dc:rights xml:lang="en">Copyright (c) 2020 Journal of Applied Engineering and Technological Science (JAETS)</dc:rights>
</oai_dc:dc>