Journal
SINTA 1
Comparison of Static Model, Adaptation Study, and CFD Simulation in Evaluating Thermal Comfort Based on Köppen Climate Classification System in Churches in Indonesia
Journal of Engineering and Technological Sciences · Vol. 53 No. 6 (2021)
ISSN 2338-5502, 2337-5779
Published 2021-12-22
Publisher Directorate for Research and Community Services, Institut Teknologi Bandung
Language eng
Abstract
This research examined thermal comfort in church buildings in Indonesia by making a comparison between three different Indonesian climatic regions using three different research models. A static model, an adaptation study model and a CFD simulation were used to find the similarities and differences between the results generated from determining thermal comfort in church buildings in the three regions. The comparison revealed that church buildings had different PMV scores at each measuring point that were inversely proportional to the subjects’ response on thermal comfort inside the buildings, i.e. points adjoining with openings affect a low PMV score and a high perceived thermal sensation, and vice versa. The CFD simulation showed that changing the conditions of the openings affects air velocity and flow into the building, which influences the subjects’ thermal comfort response inside the churches.
Collaboration network of the authors
5 authors ·
7 co-authorship links
· 3 across different organisations
Hover or tap a name to highlight its co-authors. Double-click to open the author's page.
Udayana University Universitas Nusa Nipa Maumere
Different organisations
Same organisation
Affiliation unknown
Thicker line = more joint articles · bigger circle = more articles
Show as table
Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.
Metadata source: OAI-PMH (metadata jurnal) https://journals.itb.ac.id/index.php/jets/oai, first harvested 9 Nov 2026, last seen 22 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">Comparison of Static Model, Adaptation Study, and CFD Simulation in Evaluating Thermal Comfort Based on Köppen Climate Classification System in Churches in Indonesia</dc:title>
<dc:creator>Hildegardis, Cornelia</dc:creator>
<dc:creator>Saraswati, Anak Agung Ayu Oka</dc:creator>
<dc:creator>Putra, I Dewa Gede Agung Diasana</dc:creator>
<dc:creator>Dewi, Ni Ketut Agusinta</dc:creator>
<dc:subject xml:lang="en-US">computational fluid dynamics</dc:subject>
<dc:subject xml:lang="en-US">church</dc:subject>
<dc:subject xml:lang="en-US">thermal comfort</dc:subject>
<dc:subject xml:lang="en-US">PMV</dc:subject>
<dc:subject xml:lang="en-US">perception</dc:subject>
<dc:subject xml:lang="en-US">Engineering</dc:subject>
<dc:description xml:lang="en-US">This research examined thermal comfort in church buildings in Indonesia by making a comparison between three different Indonesian climatic regions using three different research models. A static model, an adaptation study model and a CFD simulation were used to find the similarities and differences between the results generated from determining thermal comfort in church buildings in the three regions. The comparison revealed that church buildings had different PMV scores at each measuring point that were inversely proportional to the subjects’ response on thermal comfort inside the buildings, i.e. points adjoining with openings affect a low PMV score and a high perceived thermal sensation, and vice versa. The CFD simulation showed that changing the conditions of the openings affects air velocity and flow into the building, which influences the subjects’ thermal comfort response inside the churches.</dc:description>
<dc:publisher xml:lang="en-US">Directorate for Research and Community Services, Institut Teknologi Bandung</dc:publisher>
<dc:date>2021-12-22</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://journals.itb.ac.id/index.php/jets/article/view/13825</dc:identifier>
<dc:identifier>10.5614/j.eng.technol.sci.2021.53.6.6</dc:identifier>
<dc:source xml:lang="en-US">Journal of Engineering and Technological Sciences; Vol. 53 No. 6 (2021); 210606</dc:source>
<dc:source>2338-5502</dc:source>
<dc:source>2337-5779</dc:source>
<dc:source>10.5614/j.eng.technol.sci.2021.53.6</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://journals.itb.ac.id/index.php/jets/article/view/13825/5541</dc:relation>
<dc:rights xml:lang="en-US">Copyright (c) 2021 Journal of Engineering and Technological Sciences</dc:rights>
</oai_dc:dc>
Citations and indexing
OpenAlex
Indexed
via DOI
2 citations
Crossref
Indexed
via DOI
1 citation
Counts as reported by each index on 13 Nov 2026; indexes count citations differently.
OpenAlex also lists this work in: crossref.
Cite this article
APA 7
Hildegardis, C., Saraswati, A. A. A. O., Putra, I. D. G. A. D., & Dewi, N. K. A. (2021). Comparison of Static Model, Adaptation Study, and CFD Simulation in Evaluating Thermal Comfort Based on Köppen Climate Classification System in Churches in Indonesia. Journal of Engineering and Technological Sciences, 53(6). https://doi.org/10.5614/j.eng.technol.sci.2021.53.6.6
Copy
IEEE
C. Hildegardis, A. A. A. O. Saraswati, I. D. G. A. D. Putra, and N. K. A. Dewi, “Comparison of Static Model, Adaptation Study, and CFD Simulation in Evaluating Thermal Comfort Based on Köppen Climate Classification System in Churches in Indonesia,” Journal of Engineering and Technological Sciences, vol. 53, no. 6, 2021, doi: 10.5614/j.eng.technol.sci.2021.53.6.6.
Copy
Generated from the journal's metadata; check author names before use.