Melola Discovery

← Melola Discovery

Journal SINTA 1

Design and Characterization of Ultrasonic Langevin Transducer 20 kHz Using a Stepped Horn Front-Mass

Journal of Engineering and Technological Sciences · Vol. 55 No. 4 (2023) · pp. 357–372

DOI
10.5614/j.eng.technol.sci.2023.55.4.1
ISSN
2338-5502, 2337-5779
Published
2023-10-26
Publisher
Directorate for Research and Community Services, Institut Teknologi Bandung
Language
eng

Abstract

Ultrasonication is a method that is widely used in various fields. One of its applications is to accelerate the process of homogenization, emulsification, and extraction. In the ultrasonicator system, the transducer is an extremely important device. The resonant frequency, longitudinal vibration amplitude, and electromechanical coupling are the targets in designing an ultrasonic transducer. In this investigation, the main contribution was the development of a simple and effective method for mechanically tuning the resonant frequency of the transducer by adding mass to the front end of the mass or stepped horn. This study also aimed to obtain optimal results by examining the effects of geometric dimensions, bolt prestress, stress distribution, resonant frequency, amplitude, and electrical impedance. The ultrasonic transducer model was designed with a resonant frequency of 20 kHz and simulated using the finite element analysis. The steps involved included calculating the dimensions and geometric structure of the transducer, modeling using the finite-element method, and experimental validation. The simulation results and measurements showed that the series resonant frequency, electrical impedance, and effective electromechanical coupling of the Model-4 transducer 16∙13 mm radiator configuration were 20.15 kHz, 100 Ω, and 0.2229 from the simulation results, and 20.17 kHz, 24.91 Ω, and 0.2033 from the measurement results. A percentage difference, or relative error, of 0.1% was obtained between the simulation and the experimental results for this Model-4 with bolt prestressing at 15 kN.

Keywords

Collaboration network of the authors

22 authors · 80 co-authorship links · 44 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Bandung Institute of Technology
  • Indonesia University of Education
  • National University of Malaysia
  • National Research and Innovation Agency
  • Politeknik Negeri Bandung
  • State University of Jakarta
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Endang JuliastutiBandung Institute of Technology2
Irwan SetiawanPoliteknik Negeri Bandung2
Brian YuliartoBandung Institute of Technology1
Irsyad Nashirul HaqBandung Institute of Technology1
F.X. Nugroho SoelamiBandung Institute of Technology1
Edi LeksonoBandung Institute of Technology1
S. SuprijantoBandung Institute of Technology1
Hesty SusantiBandung Institute of Technology1
Vebi NadhiraBandung Institute of Technology1
Ida HamidahIndonesia University of Education1
Lilik HasanahIndonesia University of Education1
Roer Eka PawinantoIndonesia University of Education1
Ahmad AminudinIndonesia University of Education1
Widyaningrum IndrasariState University of Jakarta1
Chandra WulandariBandung Institute of Technology1
Budi MulyantiIndonesia University of Education1
Jumril YunasNational University of Malaysia1
Harbi Setyo NugrohoIndonesia University of Education1
Ahmad Rifqi Md ZainNational University of Malaysia1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OAI-PMH (metadata jurnal) https://journals.itb.ac.id/index.php/jets/oai, first harvested 9 Nov 2026, last seen 22 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Design and Characterization of Ultrasonic Langevin Transducer 20 kHz Using a Stepped Horn Front-Mass</dc:title>
	<dc:creator>Khairiyah, Aisyah Nurul</dc:creator>
	<dc:creator>Sugandi, Gandi</dc:creator>
	<dc:creator>Kurniadi, Deddy</dc:creator>
	<dc:subject xml:lang="en-US">bolt-clamped langevin transducer</dc:subject>
	<dc:subject xml:lang="en-US">effective electromechanical coupling coefficient</dc:subject>
	<dc:subject xml:lang="en-US">finite  element analysis</dc:subject>
	<dc:subject xml:lang="en-US">resonance characteristics</dc:subject>
	<dc:subject xml:lang="en-US">ultrasonication</dc:subject>
	<dc:description xml:lang="en-US">Ultrasonication is a method that is widely used in various fields. One of its applications is to accelerate the process of homogenization, emulsification, and extraction. In the ultrasonicator system, the transducer is an extremely important device. The resonant frequency, longitudinal vibration amplitude, and electromechanical coupling are the targets in designing an ultrasonic transducer. In this investigation, the main contribution was the development of a simple and effective method for mechanically tuning the resonant frequency of the transducer by adding mass to the front end of the mass or stepped horn. This study also aimed to obtain optimal results by examining the effects of geometric dimensions, bolt prestress, stress distribution, resonant frequency, amplitude, and electrical impedance. The ultrasonic transducer model was designed with a resonant frequency of 20 kHz and simulated using the finite element analysis. The steps involved included calculating the dimensions and geometric structure of the transducer, modeling using the finite-element method, and experimental validation. The simulation results and measurements showed that the series resonant frequency, electrical impedance, and effective electromechanical coupling of the Model-4 transducer 16∙13 mm radiator configuration were 20.15 kHz, 100 Ω, and 0.2229 from the simulation results, and 20.17 kHz, 24.91 Ω, and 0.2033 from the measurement results. A percentage difference, or relative error, of 0.1% was obtained between the simulation and the experimental results for this Model-4 with bolt prestressing at 15 kN.</dc:description>
	<dc:publisher xml:lang="en-US">Directorate for Research and Community Services, Institut Teknologi Bandung</dc:publisher>
	<dc:date>2023-10-26</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journals.itb.ac.id/index.php/jets/article/view/19680</dc:identifier>
	<dc:identifier>10.5614/j.eng.technol.sci.2023.55.4.1</dc:identifier>
	<dc:source xml:lang="en-US">Journal of Engineering and Technological Sciences; Vol. 55 No. 4 (2023); 357-372</dc:source>
	<dc:source>2338-5502</dc:source>
	<dc:source>2337-5779</dc:source>
	<dc:source>10.5614/j.eng.technol.sci.2023.55.4</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://journals.itb.ac.id/index.php/jets/article/view/19680/6365</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2023 Journal of Engineering and Technological Sciences</dc:rights>
</oai_dc:dc>