Generator Pulsa Arus

Journal of Mathematical and Fundamental Sciences · Vol. 3 No. 4 (2019) · pp. 181–186

ISSN
2338-5510, 2337-5760
Published
2019-02-06
Publisher
Directorate for Research and Innovation (DRI) ITB
Language
eng

Abstract

Ichtisar. Dalam penjelidikan mengenai karakteristik suatu arrester, selain mengetahui karakteristik tembus terhadap tegangan pulsa djuga perlu diselidiki sifat2 tahanan non linearnja (lazim dipergunakan Si C) terhadap pulsa arus menentukan tegangan tinggalnja (Rest spanning). Untuk kepentingan ini dipergunakan pulsa arus 5 x 10 μ sec ataupun 10 x 20 μ sec. Disini akan dibahas mengenai parameter2 rangkaian dan faktor2 jang penting diperhatikan dalam perentjanaan suatu generator pulsa arus. Abstract. In order to obtain the performance characteristic of an arrester, besides knowing the breakdown voltage of its gaps it is also necessary to know the behaviour of the non linear value element (usually Si C) with respect to current surges to get a picture of its rest voltage. For this purpose 5 x 10 μ sec or 10 x 20 μ sec current surges are used. The circuit parameters, and some important factors concerning the design of a current surges generator are discussed here.

Collaboration network of the authors

No co-authors found in Melola yet.

Metadata source: OAI-PMH (metadata jurnal) https://journals.itb.ac.id/index.php/jmfs/oai, first harvested 9 Nov 2026, last seen 22 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Generator Pulsa Arus</dc:title>
	<dc:creator>Tho, Mak Sioe</dc:creator>
	<dc:description xml:lang="en-US">Ichtisar. Dalam penjelidikan mengenai karakteristik suatu arrester, selain mengetahui karakteristik tembus terhadap tegangan pulsa djuga perlu diselidiki sifat2 tahanan non linearnja (lazim dipergunakan Si C) terhadap pulsa arus menentukan tegangan tinggalnja (Rest spanning). Untuk kepentingan ini dipergunakan pulsa arus 5 x 10 μ sec ataupun 10 x 20 μ sec. Disini akan dibahas mengenai parameter2 rangkaian dan faktor2 jang penting diperhatikan dalam perentjanaan suatu generator pulsa arus. Abstract. In order to obtain the performance characteristic of an arrester, besides knowing the breakdown voltage of its gaps it is also necessary to know the behaviour of the non linear value element (usually Si C) with respect to current surges to get a picture of its rest voltage. For this purpose  5 x 10 μ sec or 10 x 20 μ sec current surges are used. The circuit parameters, and some important factors concerning the design of a current surges generator are discussed here.</dc:description>
	<dc:publisher xml:lang="en-US">Directorate for Research and Innovation (DRI) ITB</dc:publisher>
	<dc:date>2019-02-06</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journals.itb.ac.id/index.php/jmfs/article/view/9773</dc:identifier>
	<dc:source xml:lang="en-US">Journal of Mathematical and Fundamental Sciences; Vol. 3 No. 4 (1965); 181-186</dc:source>
	<dc:source>2338-5510</dc:source>
	<dc:source>2337-5760</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://journals.itb.ac.id/index.php/jmfs/article/view/9773/3743</dc:relation>
</oai_dc:dc>