Melola Discovery

← Melola Discovery

Open access Journal SINTA 1

Implementing Underground Water Storage Tank to Stabilize Intermittent Water Supply in Jakarta, Indonesia

Journal of Regional and City Planning · Vol. 37 No. 1 (2026) · pp. 1–31

DOI
10.5614/jpwk.2026.37.1.1
ISSN
2502-6429
Published
2026-04-06
Publisher
The Directorate for Research and Innovation, Institut Teknologi Bandung
Language
eng
License
creativecommons.org/licenses/by-nc/4.0/

Abstract

This study addresses the issue of intermittent water supply in Jakarta, focusing on the use of underground water storage tanks (UWSTs) to stabilize water availability in three commercial buildings. Surveys showed that the average pressure from drinking water utilities over five consecutive days was only 4 m head—considered critically low. The research proposes installing UWSTs to store water during off-peak hours for redistribution during peak demand or supply outages. The study also analyzed the influence of commuter and resident water-use patterns, with an estimated tank capacity of 25.69 m³ per site to accommodate varying demand. Field data processing and simulations demonstrated that UWSTs can markedly improve supply consistency, particularly during peak hours. Optimizing the tank design within the space constraints in the buildings proved effective in balancing storage capacity and structural integrity. The integration of UWSTs with pressure-management strategies offers a practical and resilience-based approach to Jakarta’s urban water-supply challenges. Residential and office-sector consumption data were specifically integrated into a composite daily pattern to characterize urban peak-demand behavior in Jakarta. The solution proposed in this study is considered sustainable because it utilizes the existing water supply without increasing extraction, while improving temporal distribution efficiency during low-pressure periods.

Keywords

Collaboration network of the authors

40 authors · 182 co-authorship links · 55 across different organisations · showing the 40 most connected

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • National Research and Innovation Agency
  • IPB University
  • Pancasila University
  • Diponegoro University
  • National Nuclear Energy Agency of Indonesia
  • Badan Pengkajian dan Penerapan Teknologi
  • Sultan Ageng Tirtayasa University
  • Other organisations
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Heny SusenoNational Nuclear Energy Agency of Indonesia1
M MuslimDiponegoro University1
Chrisna Adhi SuryonoDiponegoro University1
Enggar UtariSultan Ageng Tirtayasa University1
Novian Andri AkhiriantoNational Research and Innovation Agency1
Dwi Abad TiwiNational Research and Innovation Agency1
Astisiasari AstisiasariNational Research and Innovation Agency1
Raditya Panji UmbaraNational Research and Innovation Agency1
Achmad Fakhrus ShomimNational Research and Innovation Agency1
Deliyanti GaneshaNational Research and Innovation Agency1
Dwi Agus KuncoroAffiliation unknown1
Dwi AriyaniPancasila University1
Atie Tri JuniatiPancasila University1
Muhammad FitrahPancasila University1
Dimas AndriantoIPB University1
Dimas AndriantoIPB University1
Vina OktoviantiIPB University1
Siti WahyuningsihNational Research and Innovation Agency1
Muhammad Rahman DjuwansyahAffiliation unknown1
Ania CitraresminiNational Nuclear Energy Agency of Indonesia1
Dyah MarganingrumIndonesian Institute of Sciences1
Rhazista NoviardiNational Research and Innovation Agency1
Wilda NailyNational Research and Innovation Agency1
Taufiq BachtiarNational Research and Innovation Agency1
Ratih NurjayatiNational Research and Innovation Agency1
Veny RachmawatiNational Research and Innovation Agency1
Asep MulyonoNational Research and Innovation Agency1
Hidawati HidawatiNational Research and Innovation Agency1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OAI-PMH (metadata jurnal) http://journals.itb.ac.id/index.php/jpwk/oai, first harvested 9 Nov 2026, last seen 16 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Implementing Underground Water Storage Tank  to Stabilize Intermittent Water Supply in Jakarta, Indonesia</dc:title>
	<dc:creator>Plamonia, Nicco</dc:creator>
	<dc:creator>Adhi, Rizky Pratama </dc:creator>
	<dc:creator>Jayanti, Merri </dc:creator>
	<dc:creator>Komarudin, Muhammad</dc:creator>
	<dc:creator>Kurniawan, Budi </dc:creator>
	<dc:creator>Syaefudin, Syaefudin</dc:creator>
	<dc:creator>Putra, Ahmad Pratama </dc:creator>
	<dc:creator>Pradita, Luky </dc:creator>
	<dc:creator>Suryanegara, Raden Arif </dc:creator>
	<dc:creator>Hidayaturrahman, Haerul </dc:creator>
	<dc:creator>Wahyono, Ikhsan Budi </dc:creator>
	<dc:creator>Hape, Shafira Rahmadilla </dc:creator>
	<dc:subject xml:lang="en-US">ground water tank</dc:subject>
	<dc:subject xml:lang="en-US">water supply stability</dc:subject>
	<dc:subject xml:lang="en-US">water consumption patterns</dc:subject>
	<dc:subject xml:lang="en-US">commuter and permanent resident</dc:subject>
	<dc:subject xml:lang="en-US">Jakarta water distribution</dc:subject>
	<dc:description xml:lang="en-US">This study addresses the issue of intermittent water supply in Jakarta, focusing on the use of underground water storage tanks (UWSTs) to stabilize water availability in three commercial buildings. Surveys showed that the average pressure from drinking water utilities over five consecutive days was only 4 m head—considered critically low. The research proposes installing UWSTs to store water during off-peak hours for redistribution during peak demand or supply outages. The study also analyzed the influence of commuter and resident water-use patterns, with an estimated tank capacity of 25.69 m³ per site to accommodate varying demand. Field data processing and simulations demonstrated that UWSTs can markedly improve supply consistency, particularly during peak hours. Optimizing the tank design within the space constraints in the buildings proved effective in balancing storage capacity and structural integrity. The integration of UWSTs with pressure-management strategies offers a practical and resilience-based approach to Jakarta’s urban water-supply challenges. Residential and office-sector consumption data were specifically integrated into a composite daily pattern to characterize urban peak-demand behavior in Jakarta. The solution proposed in this study is considered sustainable because it utilizes the existing water supply without increasing extraction, while improving temporal distribution efficiency during low-pressure periods.</dc:description>
	<dc:publisher xml:lang="en-US">The Directorate for Research and Innovation, Institut Teknologi Bandung</dc:publisher>
	<dc:date>2026-04-06</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US">Research Article</dc:type>
	<dc:format>application/octet-stream</dc:format>
	<dc:identifier>https://journals.itb.ac.id/index.php/jpwk/article/view/25672</dc:identifier>
	<dc:identifier>10.5614/jpwk.2026.37.1.1</dc:identifier>
	<dc:source xml:lang="en-US">Journal of Regional and City Planning; Vol. 37 No. 1 (2026); 1-31</dc:source>
	<dc:source>2502-6429</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://journals.itb.ac.id/index.php/jpwk/article/view/25672/7324</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2025 Journal of Regional and City Planning</dc:rights>
	<dc:rights xml:lang="en-US">https://creativecommons.org/licenses/by-nc/4.0/</dc:rights>
</oai_dc:dc>