Journal
SINTA 1
Analysis of Performance of Permanent Magnet Generator Fluks Axial 1 Phasa with Variation Load
Journal of Robotics and Control (JRC) · Vol. 2 No. 2 (2021) · pp. 98–102
ISSN 2715-5072, 2715-5056
Published 2021-03-19
Publisher Universitas Muhammadiyah Yogyakarta
Language eng
Abstract
With the potential of low water head energy and relatively small water discharge then it takes a low round generator to be applied to the potential of existing energy. The development of Permanent Magnet Generator (PMG), being an alternative considering the pole construction of the rotor is relatively simple compared to conventional generators, so it is technically required a more number of rotor poles in the effort to lower the speed The nominal dial generator. The purpose of this research is to analyze the 1-phase axial generator performance with varied resistive loads and inductive loads. This research has 4 stages of research: 1). Study literature. 2). Carried out testing tools. 3). Measurement of data retrieval. 4). Data analysis. From this research obtained results from the tools and measurements of the data retrieval of the performance of axial generator 1 phase with inductive and resistive load Vaiasi. Load mounted 15 watts, voltage 35.10, current 0.80, RPM 2550 when load 75 Waat, Voltage 11.50, current 1.54, RPM 2220. From these results can be concluded axial generator 1 phase currents also get bigger but voltage and rpm decreases.
Collaboration network of the authors
16 authors ·
34 co-authorship links
Hover or tap a name to highlight its co-authors. Double-click to open the author's page.
Different organisations
Same organisation
Affiliation unknown
Thicker line = more joint articles · bigger circle = more articles
Show as table
Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.
Metadata source: OAI-PMH (metadata jurnal) https://journal.umy.ac.id/index.php/jrc/oai, first harvested 9 Nov 2026, last seen 9 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">Analysis of Performance of Permanent Magnet Generator Fluks Axial 1 Phasa with Variation Load</dc:title>
<dc:creator>Saleh, Zulkiffli</dc:creator>
<dc:creator>Apriani, Yosi</dc:creator>
<dc:creator>Karim, Khoirul</dc:creator>
<dc:creator>Aldiansyah, Aldiansyah</dc:creator>
<dc:subject xml:lang="en-US">PLTMH</dc:subject>
<dc:subject xml:lang="en-US">PMG</dc:subject>
<dc:subject xml:lang="en-US">Axial Generator</dc:subject>
<dc:subject xml:lang="en-US">resistive load</dc:subject>
<dc:subject xml:lang="en-US">inductive load.</dc:subject>
<dc:description xml:lang="en-US">With the potential of low water head energy and relatively small water discharge then it takes a low round generator to be applied to the potential of existing energy. The development of Permanent Magnet Generator (PMG), being an alternative considering the pole construction of the rotor is relatively simple compared to conventional generators, so it is technically required a more number of rotor poles in the effort to lower the speed The nominal dial generator. The purpose of this research is to analyze the 1-phase axial generator performance with varied resistive loads and inductive loads. This research has 4 stages of research: 1). Study literature. 2). Carried out testing tools. 3). Measurement of data retrieval. 4). Data analysis. From this research obtained results from the tools and measurements of the data retrieval of the performance of axial generator 1 phase with inductive and resistive load Vaiasi. Load mounted 15 watts, voltage 35.10, current 0.80, RPM 2550 when load 75 Waat, Voltage 11.50, current 1.54, RPM 2220. From these results can be concluded axial generator 1 phase currents also get bigger but voltage and rpm decreases.</dc:description>
<dc:publisher xml:lang="en-US">Universitas Muhammadiyah Yogyakarta</dc:publisher>
<dc:date>2021-03-19</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://journal.umy.ac.id/index.php/jrc/article/view/8268</dc:identifier>
<dc:identifier>10.18196/jrc.2260</dc:identifier>
<dc:source xml:lang="en-US">Journal of Robotics and Control (JRC); Vol. 2 No. 2 (2021): March; 98-102</dc:source>
<dc:source>2715-5072</dc:source>
<dc:source>2715-5056</dc:source>
<dc:source>10.18196/jrc.v2i2</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://journal.umy.ac.id/index.php/jrc/article/view/8268/5619</dc:relation>
<dc:rights xml:lang="en-US">Copyright (c) 2020 Journal of Robotics and Control (JRC)</dc:rights>
</oai_dc:dc>
Citations and indexing
OpenAlex
Not checked
Crossref
Not checked
Cite this article
APA 7
Saleh, Z., Apriani, Y., Karim, K., & Aldiansyah, A. (2021). Analysis of Performance of Permanent Magnet Generator Fluks Axial 1 Phasa with Variation Load. Journal of Robotics and Control (JRC), 2(2), 98–102. https://doi.org/10.18196/jrc.2260
Copy
IEEE
Z. Saleh, Y. Apriani, K. Karim, and A. Aldiansyah, “Analysis of Performance of Permanent Magnet Generator Fluks Axial 1 Phasa with Variation Load,” Journal of Robotics and Control (JRC), vol. 2, no. 2, pp. 98–102, 2021, doi: 10.18196/jrc.2260.
Copy
Generated from the journal's metadata; check author names before use.