Melola Discovery

← Melola Discovery

Journal SINTA 1

Survey about impact voltage instability and transient stability for a power system with an integrated solar combined cycle plant in Iraq by using ETAP

Journal of Robotics and Control (JRC) · Vol. 2 No. 3 (2021) · pp. 134–139

DOI
10.18196/jrc.2366
ISSN
2715-5072, 2715-5056
Published
2021-05-05
Publisher
Universitas Muhammadiyah Yogyakarta
Language
eng

Abstract

The Analyses for power systems are more necessary for the designing, operating phase execution control and to make sure safe network operations by sufficient protection project settings. In this article, we have prepared a sufficient scientific survey about the electrical model of a 340 MW integrated solar combined cycle system (ISCCS) located in the Iraqi southern, is developed and simulation by a program called Electrical Transient Analyzer Program (ETAP) and carry out throw this program the load flow, voltage stability and short circuit analyses for this power plant with part of the national grid in Al-Basra city in an industrial region. The effect of voltage instability for the grid on system buses (load buses) of the power system is estimated. By using load flow analysis as a case study by using the Newton-Raphson algorithm, when the load buses operating at down voltage because of instability voltage of the power grid are specified and their voltages are should to improved according to given voltage limitations that are depended on buses criticality with regard to loads. The appliance on-load tap changers of the transformer and reactive power compensation are used to improve steady-state voltage stability for any instability system. The method of the optimal position for capacitor banks placement is meaning the number of capacitor banks is proposed to adding to the weak buses by using the optimal capacitor placement module of ETAP. Energy is actually required for the expansion of our country. To sustain the generation of electric power at an adequate level power system supplies power to different types of loads that are located far away from the generating plants using transmission lines.

Keywords

Collaboration network of the authors

15 authors · 31 co-authorship links · 17 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Novosibirsk State Technical University
  • Northern Technical University
  • Ural Federal University
  • Tajik Technical University named after academic M.S.Osimi
  • Middle Technical University
  • Erbil Polytechnic University
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Javod S. AhyoevNovosibirsk State Technical University2
Vadim ManusovNovosibirsk State Technical University1
Alifbek K. KirgizovTajik Technical University named after academic M.S.Osimi1
Stepan A. DmitrievUral Federal University1
Murodbek SafaralievUral Federal University1
Anvari GhulomzodaNovosibirsk State Technical University1
Firas Saaduldeen AhmedMiddle Technical University1
Truska Khalid Mohammed SalihErbil Polytechnic University1
D. A. PavlyuchenkoAffiliation unknown1
Ahmed Jadaan AliNorthern Technical University1
Rakan Khalil AntarNorthern Technical University1
Ahmed Ateya AlluNorthern Technical University1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OAI-PMH (metadata jurnal) https://journal.umy.ac.id/index.php/jrc/oai, first harvested 9 Nov 2026, last seen 22 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Survey about impact voltage instability and transient stability for a power system with an integrated solar combined cycle plant in Iraq by using ETAP</dc:title>
	<dc:creator>Abass, Ahmed Zkear</dc:creator>
	<dc:creator>Pavlyuchenko, D.A</dc:creator>
	<dc:creator>Saadallah Hussain, Zozan</dc:creator>
	<dc:subject xml:lang="en-US">load flow</dc:subject>
	<dc:subject xml:lang="en-US">ETAP</dc:subject>
	<dc:subject xml:lang="en-US">transient stability</dc:subject>
	<dc:subject xml:lang="en-US">voltage instability</dc:subject>
	<dc:subject xml:lang="en-US">optimal capacitor placement (OCP)</dc:subject>
	<dc:description xml:lang="en-US">The Analyses for power systems are more necessary for the designing, operating phase execution control and to make sure safe network operations by sufficient protection project settings. In this article, we have prepared a sufficient scientific survey about the electrical model of a 340 MW integrated solar combined cycle system (ISCCS) located in the Iraqi southern, is developed and simulation by a program called Electrical Transient Analyzer Program (ETAP) and carry out throw this program the load flow, voltage stability and short circuit analyses for this power plant with part of the national grid in Al-Basra city in an industrial region. The effect of voltage instability for the grid on system buses (load buses) of the power system is estimated. By using load flow analysis as a case study by using the Newton-Raphson algorithm, when the load buses operating at down voltage because of instability voltage of the power grid are specified and their voltages are should to improved according to given voltage limitations that are depended on buses criticality with regard to loads. The appliance on-load tap changers of the transformer and reactive power compensation are used to improve steady-state voltage stability for any instability system. The method of the optimal position for capacitor banks placement is meaning the number of capacitor banks is proposed to adding to the weak buses by using the optimal capacitor placement module of ETAP. Energy is actually required for the expansion of our country. To sustain the generation of electric power at an adequate level power system supplies power to different types of loads that are located far away from the generating plants using transmission lines.</dc:description>
	<dc:publisher xml:lang="en-US">Universitas Muhammadiyah Yogyakarta</dc:publisher>
	<dc:date>2021-05-05</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journal.umy.ac.id/index.php/jrc/article/view/8804</dc:identifier>
	<dc:identifier>10.18196/jrc.2366</dc:identifier>
	<dc:source xml:lang="en-US">Journal of Robotics and Control (JRC); Vol. 2 No. 3 (2021): May; 134-139</dc:source>
	<dc:source>2715-5072</dc:source>
	<dc:source>2715-5056</dc:source>
	<dc:source>10.18196/jrc.v2i3</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://journal.umy.ac.id/index.php/jrc/article/view/8804/5758</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2020 Journal of Robotics and Control (JRC)</dc:rights>
</oai_dc:dc>