Journal
SINTA 1
Adaptive threshold PCA for fault detection and isolation
Journal of Robotics and Control (JRC) · Vol. 2 No. 3 (2021) · pp. 119–125
ISSN 2715-5072, 2715-5056
Published 2021-05-05
Publisher Universitas Muhammadiyah Yogyakarta
Language eng
Abstract
Fault diagnosis is an important issue in industrial processes to avoid economic losses, process damage, and to guarantee safe working conditions for the operators. For high scale industrial processes the data-driven based methods are the best solution for process monitoring and fault diagnosis. Thus, in this paper, the principal component analysis is shown to detect and isolate faults. Also, a dynamic threshold is implemented to avoid false alarms because incipient faults are difficult to be detected. As a case of study, the Tennessee Eastman (TE) process is used to apply this strategy because the interaction among five units with internal control loops makes difficult to have an approached model. As results are shown the detection times, for cases where were analyzed incipient faults, the time required for fault detection must be improved, in this work, an adaptive threshold was used to reduce the false alarms but it also increases the detection times. It was concluded that the Q chart gave a better result for fault detection; the isolation times were similar to the detection ones. Two incipient faults could not be detected, the fault detection rate was similar to the shown in literature, but the detection times were better in 35% of the cases, unfortunately for four faults the detection times were bigger than the reported in other papers. It is proposed to help this method with independent component analysis due it is not guaranteed to have a Gaussian distribution in the samples.
Collaboration network of the authors
14 authors ·
42 co-authorship links
· 33 across different organisations
Hover or tap a name to highlight its co-authors. Double-click to open the author's page.
Universidad Politécnica de Pachuca Universitas Ahmad Dahlan Universidad Autónoma del Estado de Hidalgo Universidad Politécnica Metropolitana de Hidalgo Tecnológico Nacional de México King Fahd University of Petroleum and Minerals University of Tripoli Other organisations Affiliation unknown
Different organisations
Same organisation
Affiliation unknown
Thicker line = more joint articles · bigger circle = more articles
Show as table
Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.
Metadata source: OAI-PMH (metadata jurnal) https://journal.umy.ac.id/index.php/jrc/oai, first harvested 9 Nov 2026, last seen 16 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">Adaptive threshold PCA for fault detection and isolation</dc:title>
<dc:creator>Márquez-Vera, Marco Antonio</dc:creator>
<dc:creator>López-Ortega, Omar</dc:creator>
<dc:creator>Ramos-Velasco, Luis Enrique</dc:creator>
<dc:creator>Rodríguez-Romero, Andrea</dc:creator>
<dc:creator>Ramos-Fernández, Julio César</dc:creator>
<dc:creator>Hernández-Salazar, Jorge Adalberto</dc:creator>
<dc:subject xml:lang="en-US">Fault detection</dc:subject>
<dc:subject xml:lang="en-US">PCA</dc:subject>
<dc:subject xml:lang="en-US">incipient faults</dc:subject>
<dc:description xml:lang="en-US">Fault diagnosis is an important issue in industrial processes to avoid economic losses, process damage, and to guarantee safe working conditions for the operators. For high scale industrial processes the data-driven based methods are the best solution for process monitoring and fault diagnosis. Thus, in this paper, the principal component analysis is shown to detect and isolate faults. Also, a dynamic threshold is implemented to avoid false alarms because incipient faults are difficult to be detected. As a case of study, the Tennessee Eastman (TE) process is used to apply this strategy because the interaction among five units with internal control loops makes difficult to have an approached model. As results are shown the detection times, for cases where were analyzed incipient faults, the time required for fault detection must be improved, in this work, an adaptive threshold was used to reduce the false alarms but it also increases the detection times. It was concluded that the Q chart gave a better result for fault detection; the isolation times were similar to the detection ones. Two incipient faults could not be detected, the fault detection rate was similar to the shown in literature, but the detection times were better in 35% of the cases, unfortunately for four faults the detection times were bigger than the reported in other papers. It is proposed to help this method with independent component analysis due it is not guaranteed to have a Gaussian distribution in the samples.</dc:description>
<dc:publisher xml:lang="en-US">Universitas Muhammadiyah Yogyakarta</dc:publisher>
<dc:date>2021-05-05</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://journal.umy.ac.id/index.php/jrc/article/view/8826</dc:identifier>
<dc:identifier>10.18196/jrc.2364</dc:identifier>
<dc:source xml:lang="en-US">Journal of Robotics and Control (JRC); Vol. 2 No. 3 (2021): May; 119-125</dc:source>
<dc:source>2715-5072</dc:source>
<dc:source>2715-5056</dc:source>
<dc:source>10.18196/jrc.v2i3</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://journal.umy.ac.id/index.php/jrc/article/view/8826/5756</dc:relation>
<dc:rights xml:lang="en-US">Copyright (c) 2020 Journal of Robotics and Control (JRC)</dc:rights>
</oai_dc:dc>
Citations and indexing
OpenAlex
Indexed
via DOI
6 citations
Crossref
Indexed
via DOI
4 citations
Counts as reported by each index on 13 Nov 2026; indexes count citations differently.
OpenAlex also lists this work in: crossref.
Cite this article
APA 7
Márquez-Vera, M. A., López-Ortega, O., Ramos-Velasco, L. E., Rodríguez-Romero, A., Ramos-Fernández, J. C., & Hernández-Salazar, J. A. (2021). Adaptive threshold PCA for fault detection and isolation. Journal of Robotics and Control (JRC), 2(3), 119–125. https://doi.org/10.18196/jrc.2364
Copy
IEEE
M. A. Márquez-Vera, O. López-Ortega, L. E. Ramos-Velasco, A. Rodríguez-Romero, J. C. Ramos-Fernández, and J. A. Hernández-Salazar, “Adaptive threshold PCA for fault detection and isolation,” Journal of Robotics and Control (JRC), vol. 2, no. 3, pp. 119–125, 2021, doi: 10.18196/jrc.2364.
Copy
Generated from the journal's metadata; check author names before use.