Melola Discovery

← Melola Discovery

Journal SINTA 1

Adaptive threshold PCA for fault detection and isolation

Journal of Robotics and Control (JRC) · Vol. 2 No. 3 (2021) · pp. 119–125

DOI
10.18196/jrc.2364
ISSN
2715-5072, 2715-5056
Published
2021-05-05
Publisher
Universitas Muhammadiyah Yogyakarta
Language
eng

Abstract

Fault diagnosis is an important issue in industrial processes to avoid economic losses, process damage, and to guarantee safe working conditions for the operators. For high scale industrial processes the data-driven based methods are the best solution for process monitoring and fault diagnosis. Thus, in this paper, the principal component analysis is shown to detect and isolate faults. Also, a dynamic threshold is implemented to avoid false alarms because incipient faults are difficult to be detected. As a case of study, the Tennessee Eastman (TE) process is used to apply this strategy because the interaction among five units with internal control loops makes difficult to have an approached model. As results are shown the detection times, for cases where were analyzed incipient faults, the time required for fault detection must be improved, in this work, an adaptive threshold was used to reduce the false alarms but it also increases the detection times. It was concluded that the Q chart gave a better result for fault detection; the isolation times were similar to the detection ones. Two incipient faults could not be detected, the fault detection rate was similar to the shown in literature, but the detection times were better in 35% of the cases, unfortunately for four faults the detection times were bigger than the reported in other papers. It is proposed to help this method with independent component analysis due it is not guaranteed to have a Gaussian distribution in the samples.

Keywords

Collaboration network of the authors

14 authors · 42 co-authorship links · 33 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Universidad Politécnica de Pachuca
  • Universitas Ahmad Dahlan
  • Universidad Autónoma del Estado de Hidalgo
  • Universidad Politécnica Metropolitana de Hidalgo
  • Tecnológico Nacional de México
  • King Fahd University of Petroleum and Minerals
  • University of Tripoli
  • Other organisations
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Alfian Ma’arifUniversitas Ahmad Dahlan2
Magdi S. MahmoudKing Fahd University of Petroleum and Minerals2
Ahmed Jaber AbougarairUniversity of Tripoli1
Edwin Albert UmohAffiliation unknown1
Safinta Nurindra RahmadhiaUniversitas Ahmad Dahlan1
Samir LadaciEcole Nationale Polytechnique de Constantine1
Abdullah ÇakanKonya Technical University1
Jonattan Niño ParadaUniversidad de los Llanos1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OAI-PMH (metadata jurnal) https://journal.umy.ac.id/index.php/jrc/oai, first harvested 9 Nov 2026, last seen 16 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Adaptive threshold PCA for fault detection and isolation</dc:title>
	<dc:creator>Márquez-Vera, Marco Antonio</dc:creator>
	<dc:creator>López-Ortega, Omar</dc:creator>
	<dc:creator>Ramos-Velasco, Luis Enrique</dc:creator>
	<dc:creator>Rodríguez-Romero, Andrea</dc:creator>
	<dc:creator>Ramos-Fernández, Julio César</dc:creator>
	<dc:creator>Hernández-Salazar, Jorge Adalberto</dc:creator>
	<dc:subject xml:lang="en-US">Fault detection</dc:subject>
	<dc:subject xml:lang="en-US">PCA</dc:subject>
	<dc:subject xml:lang="en-US">incipient faults</dc:subject>
	<dc:description xml:lang="en-US">Fault diagnosis is an important issue in industrial processes to avoid economic losses, process damage, and to guarantee safe working conditions for the operators. For high scale industrial processes the data-driven based methods are the best solution for process monitoring and fault diagnosis. Thus, in this paper, the principal component analysis is shown to detect and isolate faults. Also, a dynamic threshold is implemented to avoid false alarms because incipient faults are difficult to be detected. As a case of study, the Tennessee Eastman (TE) process is used to apply this strategy because the interaction among five units with internal control loops makes difficult to have an approached model. As results are shown the detection times, for cases where were analyzed incipient faults, the time required for fault detection must be improved, in this work, an adaptive threshold was used to reduce the false alarms but it also increases the detection times. It was concluded that the Q chart gave a better result for fault detection; the isolation times were similar to the detection ones. Two incipient faults could not be detected, the fault detection rate was similar to the shown in literature, but the detection times were better in 35% of the cases, unfortunately for four faults the detection times were bigger than the reported in other papers. It is proposed to help this method with independent component analysis due it is not guaranteed to have a Gaussian distribution in the samples.</dc:description>
	<dc:publisher xml:lang="en-US">Universitas Muhammadiyah Yogyakarta</dc:publisher>
	<dc:date>2021-05-05</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journal.umy.ac.id/index.php/jrc/article/view/8826</dc:identifier>
	<dc:identifier>10.18196/jrc.2364</dc:identifier>
	<dc:source xml:lang="en-US">Journal of Robotics and Control (JRC); Vol. 2 No. 3 (2021): May; 119-125</dc:source>
	<dc:source>2715-5072</dc:source>
	<dc:source>2715-5056</dc:source>
	<dc:source>10.18196/jrc.v2i3</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://journal.umy.ac.id/index.php/jrc/article/view/8826/5756</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2020 Journal of Robotics and Control (JRC)</dc:rights>
</oai_dc:dc>