Melola Discovery

← Melola Discovery

Journal SINTA 1

Modeling and Designing of Active Vibration Isolation Platform

Journal of Robotics and Control (JRC) · Vol. 5 No. 4 (2024) · pp. 1091–1097

DOI
10.18196/jrc.v5i4.22103
ISSN
2715-5072, 2715-5056
Published
2024-06-10
Publisher
Universitas Muhammadiyah Yogyakarta
Language
eng

Abstract

The most important task of ensuring the quality of operation of technological and research equipment is its effective protection from external vibration effects in the area of low frequencies, at which resonance phenomena are manifested. For this purpose, various types of vibration isolation systems are used, which are divided into passive and active. Passive systems effectively suppress vibrations at frequencies above 40-50 Hz, at lower frequencies such systems are ineffective as they cannot compensate for resonance phenomena. In this case, active vibration isolation systems are used. The active dampers and platform based on magnetorheological (MR) elastomers presented in the paper demonstrated higher vibration isolation efficiency in the frequency range of 0.3-3 Hz compared to the piezoelectric system and in the frequency range of 0.3-20 Hz compared to the platform based on electromagnetic power drive. At these frequencies, the vibration displacement amplitude transfer coefficient was less than 0.075. The use of MR effect makes it possible to regulate the stiffness and deformation of the elastic active element made of MR elastomer by changing the magnitude of magnetic induction. In this case it is possible to control dynamic and precision characteristics of the active damper, as well as to increase the efficiency of vibration isolation. During dynamic modelling of the active MP damper the differential equations and transfer functions of its elements were determined. Modelling in Simulink MATLAB software environment allowed to determine the transient process of damper movement under the influence of harmonic oscillations, select the type of regulator and calculate its tuning parameters. Experimental studies were carried out on a vibration test bench and confirmed the modelling results at frequencies of 0.3-50 Hz. At frequencies higher than 50 Hz passive vibration isolation begins to prevail due to absorption of vibration energy in the MR elastomer, which is not taken into account in the modelling. The experimental amplitude-frequency response of the platform showed high vibration isolation efficiency at frequencies of 0.3-100 Hz with vibration displacement amplitude transfer coefficient less than 0.075.

Keywords

Collaboration network of the authors

3 authors · 3 co-authorship links

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OAI-PMH (metadata jurnal) https://journal.umy.ac.id/index.php/jrc/oai, first harvested 9 Nov 2026, last seen 22 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Modeling and Designing of Active Vibration Isolation Platform</dc:title>
	<dc:creator>Mikhailov, Valery</dc:creator>
	<dc:creator>Kopylov, Alexey</dc:creator>
	<dc:creator>Kazakov, Alexander</dc:creator>
	<dc:subject xml:lang="en-US">Dynamic Modelling</dc:subject>
	<dc:subject xml:lang="en-US">Automatic Control</dc:subject>
	<dc:subject xml:lang="en-US">Active Vibration Isolation</dc:subject>
	<dc:subject xml:lang="en-US">Magnetorheological Elastomers</dc:subject>
	<dc:subject xml:lang="en-US">Amplitude-Frequency Characteristic.</dc:subject>
	<dc:description xml:lang="en-US">The most important task of ensuring the quality of operation of technological and research equipment is its effective protection from external vibration effects in the area of low frequencies, at which resonance phenomena are manifested. For this purpose, various types of vibration isolation systems are used, which are divided into passive and active. Passive systems effectively suppress vibrations at frequencies above 40-50 Hz, at lower frequencies such systems are ineffective as they cannot compensate for resonance phenomena. In this case, active vibration isolation systems are used. The active dampers and platform based on magnetorheological (MR) elastomers presented in the paper demonstrated higher vibration isolation efficiency in the frequency range of 0.3-3 Hz compared to the piezoelectric system and in the frequency range of 0.3-20 Hz compared to the platform based on electromagnetic power drive. At these frequencies, the vibration displacement amplitude transfer coefficient was less than 0.075.  The use of MR effect makes it possible to regulate the stiffness and deformation of the elastic active element made of MR elastomer by changing the magnitude of magnetic induction. In this case it is possible to control dynamic and precision characteristics of the active damper, as well as to increase the efficiency of vibration isolation.  During dynamic modelling of the active MP damper the differential equations and transfer functions of its elements were determined. Modelling in Simulink MATLAB software environment allowed to determine the transient process of damper movement under the influence of harmonic oscillations, select the type of regulator and calculate its tuning parameters. Experimental studies were carried out on a vibration test bench and confirmed the modelling results at frequencies of 0.3-50 Hz. At frequencies higher than 50 Hz passive vibration isolation begins to prevail due to absorption of vibration energy in the MR elastomer, which is not taken into account in the modelling. The experimental amplitude-frequency response of the platform showed high vibration isolation efficiency at frequencies of 0.3-100 Hz with vibration displacement amplitude transfer coefficient less than 0.075.</dc:description>
	<dc:publisher xml:lang="en-US">Universitas Muhammadiyah Yogyakarta</dc:publisher>
	<dc:date>2024-06-10</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journal.umy.ac.id/index.php/jrc/article/view/22103</dc:identifier>
	<dc:identifier>10.18196/jrc.v5i4.22103</dc:identifier>
	<dc:source xml:lang="en-US">Journal of Robotics and Control (JRC); Vol. 5 No. 4 (2024); 1091-1097</dc:source>
	<dc:source>2715-5072</dc:source>
	<dc:source>2715-5056</dc:source>
	<dc:source>10.18196/jrc.v5i4</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://journal.umy.ac.id/index.php/jrc/article/view/22103/9268</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2024 Valery Mikhailov, Alexey Kopylov, Alexander Kazakov</dc:rights>
</oai_dc:dc>