Melola Discovery

← Melola Discovery

Journal SINTA 1

Implementation of Chest Compression for Cardiac Arrest Patient in Indonesia: True or False

Jurnal Ners · Vol. 16 No. 1 (2021) · pp. 13–16

DOI
10.20473/jn.v16i1.17508
ISSN
2502-5791, 1858-3598
Published
2021-01-19
Publisher
Universitas Airlangga
Language
eng

Abstract

Introduction: The highest cause of death is cardiac arrest. Proper manual chest compression will increase survival of cardiac arrest. The aim of this study was to know the implementation of chest compressions for cardiac arrest patient in Indonesia.Methods: This study used a descriptive quantitative design. The samples were nurse and code blue team when performing manual chest compression to 74 patients experiencing cardiac arrest. The sample have body mass index (BMI) > 20. Research was conducted in two hospitals in Java, Indonesia. Implementation of chest compression is measured based on depth accuracy. Depth accuracy of chest compressions was assessed based on the comparison of the number of R waves with a height >10 mV on the bedside monitor with the number of chest compressions performed. The data were analyzed descriptively (mean, median, mode, standard deviation, and variances).Results: Result of this study is the mean of accuracy of compression depth is 75.97%. The result shows accuracy of compression depth on manual chest compression still under the American Heart Association (AHA) recommendation of 80%, because chest compression rate are not standardized. Chest compression rates are between 100-160 rates/minute, while AHA's recommendations are 100-120 rates/minute. High compression speed causes a decrease in accuracy of chest compressions depth.Conclusion: In conclusion, the implementation of chest compressions in Indonesia if measured based on accuracy of compression depth is not effective. Nurses and the code blue team have to practice considering the use of cardiac resuscitation aids.

Keywords

Collaboration network of the authors

40 authors · 102 co-authorship links · 45 across different organisations · showing the 40 most connected

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Diponegoro University
  • University of Indonesia
  • Politeknik Kesehatan Kemenkes Surakarta
  • Institut Teknologi dan Kesehatan Bali
  • Aisyah University
  • Rumah Sakit Umum Pusat Nasional Dr. Cipto Mangunkusumo
  • Universitas Pembangunan Nasional Veteran Jakarta
  • Other organisations
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Agung Dwi WaluyoUniversity of Indonesia2
Astuti Yuni NursasiUniversity of Indonesia2
M Agung AkbarUniversity of Indonesia2
Ikhwan AmirudinAisyah University2
Elly NurachmahUniversity of Indonesia2
Dewi GayatriUniversity of Indonesia2
Ni Luh Putu Inca Buntari AgustiniInstitut Teknologi dan Kesehatan Bali1
Israfil IsrafilInstitut Teknologi dan Kesehatan Bali1
I Gede Putu Darma SuyasaInstitut Teknologi dan Kesehatan Bali1
Sri Hananto Ponco NugrohoAffiliation unknown1
Niken Safitri Dyan KusumaningrumDiponegoro University1
Avin MariaDiponegoro University1
Yuyun SetyoriniPoliteknik Kesehatan Kemenkes Surakarta1
Yopi Harwinanda ArdesaPoliteknik Kesehatan Kemenkes Surakarta1
Madya SulisnoDiponegoro University1
Richal Grace Zefanya UlyDiponegoro University1
Fatma LestariUniversity of Indonesia1
Arcellia Farosyah PutriRumah Sakit Umum Pusat Nasional Dr. Cipto Mangunkusumo1
Amelia KiminUniversity of Indonesia1
Yati AfriyantiUniversity of Indonesia1
Basuki SupartonoUniversitas Pembangunan Nasional Veteran Jakarta1
Dian AyubiUniversity of Indonesia1
Retnaningsih RetnaningsihDiponegoro University1
Wenny TrisnaningtyasDiponegoro University1
Dody SetyawanDiponegoro University1
Reni Sulung UtamiDiponegoro University1
Elsa NaviatiDiponegoro University1
Ahmat PujiantoUniversitas Borneo Tarakan1
Kasmad KasmadAffiliation unknown1
Wahyu HidayatiDiponegoro University1
Sukarmin SukarminUniversitas Muhammadiyah Kudus1
Sri YonaUniversity of Indonesia1
Mardiyono MardiyonoJenderal Soedirman University1
Khoirunnisa’ MunawarohDiponegoro University1
Henni KusumaDiponegoro University1
Chandra Bagus RopyantoDiponegoro University1
Susana WidyaningsihDiponegoro University1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OAI-PMH (metadata jurnal) http://e-journal.unair.ac.id/index.php/JNERS/oai, first harvested 9 Nov 2026, last seen 22 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Implementation of Chest Compression for Cardiac Arrest Patient in Indonesia: True or False</dc:title>
	<dc:creator>Darmawan, Rendi Editya</dc:creator>
	<dc:creator>Sujianto, Untung</dc:creator>
	<dc:creator>Rochana, Nana</dc:creator>
	<dc:subject xml:lang="en-US">accuracy of compression depth</dc:subject>
	<dc:subject xml:lang="en-US">cardiac arrest</dc:subject>
	<dc:subject xml:lang="en-US">chest compression</dc:subject>
	<dc:description xml:lang="en-US">Introduction: The highest cause of death is cardiac arrest. Proper manual chest compression will increase survival of cardiac arrest. The aim of this study was to know the implementation of chest compressions for cardiac arrest patient in Indonesia.Methods: This study used a descriptive quantitative design. The samples were nurse and code blue team when performing manual chest compression to 74 patients experiencing cardiac arrest. The sample have body mass index (BMI) &amp;gt; 20. Research was conducted in two hospitals in Java, Indonesia.  Implementation of chest compression is measured based on depth accuracy. Depth accuracy of chest compressions was assessed based on the comparison of the number of R waves with a height &amp;gt;10 mV on the bedside monitor with the number of chest compressions performed. The data were analyzed descriptively (mean, median, mode, standard deviation, and variances).Results: Result of this study is the mean of accuracy of compression depth is 75.97%. The result shows accuracy of compression depth on manual chest compression still under the American Heart Association (AHA) recommendation of 80%, because chest compression rate are not standardized. Chest compression rates are between 100-160 rates/minute, while AHA's recommendations are 100-120 rates/minute. High compression speed causes a decrease in accuracy of chest compressions depth.Conclusion: In conclusion, the implementation of chest compressions in Indonesia if measured based on accuracy of compression depth is not effective. Nurses and the code blue team have to practice considering the use of cardiac resuscitation aids.</dc:description>
	<dc:publisher xml:lang="en-US">Universitas Airlangga</dc:publisher>
	<dc:date>2021-01-19</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://e-journal.unair.ac.id/JNERS/article/view/17508</dc:identifier>
	<dc:identifier>10.20473/jn.v16i1.17508</dc:identifier>
	<dc:source xml:lang="en-US">Jurnal Ners; Vol. 16 No. 1 (2021): APRIL 2021; 13-16</dc:source>
	<dc:source>2502-5791</dc:source>
	<dc:source>1858-3598</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://e-journal.unair.ac.id/JNERS/article/view/17508/pdf</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2021 Jurnal Ners</dc:rights>
</oai_dc:dc>