Investigation and failure analysis of a diesel generator connecting rod
Mechanical Engineering for Society and Industry · Vol. 2 No. 2 (2022) · pp. 64–71
ISSN 2798-5245
Published 2022-05-20
Publisher Universitas Muhammadiyah Magelang
Language en
Abstract
This article reports a failure analysis of a diesel generator set connecting rod type 3516 B that has operated for 79,678 hours. From visual observation, connecting rod cylinder #10 has changed color in the shank area. This phenomenon may represent many cases of generator failure, so an analysis to identify the root cause of the failure is needed for scientific literature. In this case, fault tree analysis, SEM-EDX, chemical composition, and microstructure testing were performed to obtain more comprehensive results. Through fault tree analysis, we found that the connecting rod damage was caused by compression leakage due to wear on the cylinder liner. Scanning Electron Microscopy (SEM) analysis shows that the piston rod material is discolored due to heat, namely the formation of iron oxide. The heat level received by the connecting rod is around 200 °C. We also found a finely formed, easy-to-clean scale where the thickness ranged from 0.00127–0.008 mm. Finally, EDX analysis showed high levels of iron (Fe) and oxygen (O) confirming that the formation of iron-oxide on the metal surface was due to the influence of heat.
Collaboration network of the authors
15 authors ·
32 co-authorship links
· 3 across different organisations
Hover or tap a name to highlight its co-authors. Double-click to open the author's page.
Universiti Malaysia Terengganu Universiti Malaysia Pahang Al-Sultan Abdullah Affiliation unknown
Different organisations
Same organisation
Affiliation unknown
Thicker line = more joint articles · bigger circle = more articles
Show as table
Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.
Metadata source: OAI-PMH (metadata jurnal) https://journal.unimma.ac.id/index.php/mesi/oai, first harvested 9 Nov 2026, last seen 22 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en">Investigation and failure analysis of a diesel generator connecting rod</dc:title>
<dc:creator xml:lang="en">Wilarso, Wilarso</dc:creator>
<dc:creator xml:lang="en">Noor, Che Wan Mohd</dc:creator>
<dc:creator xml:lang="en">Ayob, Ahmad Faisal Mohamad</dc:creator>
<dc:creator xml:lang="en">Mansor, Wan Nurdiyana Wan</dc:creator>
<dc:subject xml:lang="en">Connecting Rod</dc:subject>
<dc:subject xml:lang="en">Microstructure</dc:subject>
<dc:subject xml:lang="en">SEM-EDX</dc:subject>
<dc:subject xml:lang="en">Fault tree analysis</dc:subject>
<dc:description xml:lang="en">This article reports a failure analysis of a diesel generator set connecting rod type 3516 B that has operated for 79,678 hours. From visual observation, connecting rod cylinder #10 has changed color in the shank area. This phenomenon may represent many cases of generator failure, so an analysis to identify the root cause of the failure is needed for scientific literature. In this case, fault tree analysis, SEM-EDX, chemical composition, and microstructure testing were performed to obtain more comprehensive results. Through fault tree analysis, we found that the connecting rod damage was caused by compression leakage due to wear on the cylinder liner. Scanning Electron Microscopy (SEM) analysis shows that the piston rod material is discolored due to heat, namely the formation of iron oxide. The heat level received by the connecting rod is around 200 °C. We also found a finely formed, easy-to-clean scale where the thickness ranged from 0.00127–0.008 mm. Finally, EDX analysis showed high levels of iron (Fe) and oxygen (O) confirming that the formation of iron-oxide on the metal surface was due to the influence of heat.</dc:description>
<dc:publisher xml:lang="en">Universitas Muhammadiyah Magelang</dc:publisher>
<dc:date>2022-05-20</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://journal.unimma.ac.id/mesi/article/view/6624</dc:identifier>
<dc:identifier>10.31603/mesi.6624</dc:identifier>
<dc:source xml:lang="en">Mechanical Engineering for Society and Industry; Vol. 2 No. 2 (2022); 64-71</dc:source>
<dc:source>2798-5245</dc:source>
<dc:language>en</dc:language>
<dc:relation>https://journal.unimma.ac.id/mesi/article/view/6624/3304</dc:relation>
<dc:rights xml:lang="en">Copyright (c) 2022 Wilarso Wilarso, Che Wan Mohd Noor, Ahmad Faisal Mohamad Ayob, Wan Nurdiyana Wan Mansor</dc:rights>
</oai_dc:dc>
Citations and indexing
OpenAlex
Indexed
via DOI
9 citations
Crossref
Indexed
via DOI
5 citations
Counts as reported by each index on 13 Nov 2026; indexes count citations differently.
OpenAlex also lists this work in: crossref.
Cite this article
APA 7
Wilarso, W., Noor, C. W. M., Ayob, A. F. M., & Mansor, W. N. W. (2022). Investigation and failure analysis of a diesel generator connecting rod. Mechanical Engineering for Society and Industry, 2(2), 64–71. https://doi.org/10.31603/mesi.6624
Copy
IEEE
W. Wilarso, C. W. M. Noor, A. F. M. Ayob, and W. N. W. Mansor, “Investigation and failure analysis of a diesel generator connecting rod,” Mechanical Engineering for Society and Industry, vol. 2, no. 2, pp. 64–71, 2022, doi: 10.31603/mesi.6624.
Copy
Generated from the journal's metadata; check author names before use.