Melola Discovery

← Melola Discovery

Journal SINTA 1

Voltammetric Determination of Paracetamol with Carbon Paste Electrode Modified with Molecularly Imprinted Electropolymer

Molekul: Jurnal Ilmiah Kimia · Vol. 17 No. 1 (2022) · pp. 30–38

DOI
10.20884/1.jm.2022.17.1.5595
ISSN
2503-0310, 1907-9761
Published
2022-03-13
Publisher
Universitas Jenderal Soedirman
Language
eng

Abstract

Paracetamol is a commom analgesic and antipyretic drug which used for reliefing fever and head ache. The determination of paracetamol dose in pharmaceuticals is very important, becauce an overdose can cause fulminating hepatic necrosis and other toxic effects. Therefore, it is necessary to measure the dose of paracetamol for the patient with precision to avoid harm. Many analytical methodologies have been proposed for determination of paracetamol dose. One of the methods was developed in the past two decades. Generally, electroanalytical approach especially voltammetry method is particularly design for determination of paracetamol dose especially in modifying electrode. This study aims to modified carbon paste electrode with molecularly imprinted polymer (MIP). Significant advantages of using MIP are the superior stability, low cost and ease of preparation. The poly (3-aminiophenol) film was prepared by cyclic voltammetry method and 3-aminophenol monomer in supporting electrolyte (HClO4) with and whitout presence of paracetamol molecule. The effect of paracetamol was seen at cyclic voltammogram was founded, where oxidation peak potential of poly (3-aminophenol) shifted to more cathodic potentials from 0.948 to 0.780 V, in presence of paracetamol. The Ipa showed a good linear relationship with concentration in the range 0.01–0.1 mM, and the detection limit was 4,63 μM.

Collaboration network of the authors

6 authors · 10 co-authorship links · 4 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Bandung Institute of Technology
  • Universitas Bali Internasional
  • Universitas Gadjah Mada
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Buchari BuchariBandung Institute of Technology3
Suryo GandasasmitaBandung Institute of Technology3
Adhitasari SuratmanUniversitas Gadjah Mada2
Abdul Haris WatoniBandung Institute of Technology1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OAI-PMH (metadata jurnal) https://jos.unsoed.ac.id/index.php/jm/oai, first harvested 9 Nov 2026, last seen 16 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US"> Voltammetric Determination of Paracetamol with Carbon Paste Electrode Modified with Molecularly Imprinted Electropolymer</dc:title>
	<dc:creator>Aryasa, I Wayan Tanjung</dc:creator>
	<dc:creator>Noviandri, Indra</dc:creator>
	<dc:description xml:lang="en-US">Paracetamol is a commom analgesic and antipyretic drug which used for reliefing fever and head ache. The determination of paracetamol dose in pharmaceuticals is very important, becauce an overdose can cause fulminating hepatic necrosis and other toxic effects. Therefore, it is necessary to measure the dose of paracetamol for the patient with precision to avoid harm. Many analytical methodologies have been proposed for determination of paracetamol dose. One of the methods was developed in the past two decades. Generally, electroanalytical approach especially voltammetry method is particularly design for determination of paracetamol dose especially in modifying electrode. This study aims to modified carbon paste electrode with molecularly imprinted polymer (MIP). Significant advantages of using MIP are the superior stability, low cost and ease of preparation. The poly (3-aminiophenol) film was prepared by cyclic voltammetry method and 3-aminophenol monomer in supporting electrolyte (HClO4) with and whitout presence of paracetamol molecule. The effect of paracetamol was seen at cyclic voltammogram was founded, where oxidation peak potential of poly (3-aminophenol) shifted to more cathodic potentials from 0.948 to 0.780 V, in presence of paracetamol. The Ipa showed a good linear relationship with concentration in the range 0.01–0.1 mM, and the detection limit was 4,63 μM.</dc:description>
	<dc:publisher xml:lang="en-US">Universitas Jenderal Soedirman</dc:publisher>
	<dc:date>2022-03-13</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://jos.unsoed.ac.id/index.php/jm/article/view/5595</dc:identifier>
	<dc:identifier>10.20884/1.jm.2022.17.1.5595</dc:identifier>
	<dc:source xml:lang="en-US">Molekul; Vol 17 No 1 (2022); 30-38</dc:source>
	<dc:source>2503-0310</dc:source>
	<dc:source>1907-9761</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://jos.unsoed.ac.id/index.php/jm/article/view/5595/2816</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2022 Molekul</dc:rights>
	<dc:rights xml:lang="en-US">http://jos.unsoed.ac.id/index.php/jm/index</dc:rights>
</oai_dc:dc>