Melola Discovery

← Melola Discovery

Journal SINTA 1

Carbon-Oxalate (C-Ox) Practicum Waste as an Adsorbent Material Candidate in the Chemistry Laboratory

Molekul: Jurnal Ilmiah Kimia · Vol. 17 No. 3 (2022) · pp. 421–427

DOI
10.20884/1.jm.2022.17.3.6463
ISSN
2503-0310, 1907-9761
Published
2022-11-19
Publisher
Universitas Jenderal Soedirman
Language
eng

Abstract

This study aims to treat carbon and oxalate practicum waste as an adsorbent material candidate in the Chemistry Laboratory. Practicum waste was used to synthesise carbon-oxalate (C-Ox) by using wet (C-OxW) and semi-wet (C-OxDs) impregnation methods. The products were tested by SEM and FTIR. The adsorption was tested by contacting each 1 gram of C-Ox with various concentrations of chromium ions waste for 24 hours while shaking. The filtrate was measured by AAS. The data obtained were compared with standard activated carbon (CC) as control and analyzed with Freundlich and Langmuir isotherm equations. The results showed that C-Ox can be used as an adsorbent in the chemistry laboratory. Based on the SEM test, the pores of C-OxW were seen to be most than C-OxDs and CC. Adsorption of chromium ions of C-OxW and C-OxDs were more effective than CC. C-Ox test by FTIR showed very sharp wavenumbers appeared at 3674.5 and 3705.41 cm-1 for the hydroxyl groups; 1697.4 cm-1 for C=O; and 1141.8 cm-1 for C-O. The determination coefficient (R2) of Freundlich isotherm of CC and C-Ox were higher than Langmuir isotherm, and on the other hand, R2 of C-OxDs was shown oppositely.

Collaboration network of the authors

6 authors · 11 co-authorship links · 4 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Universitas Pendidikan Ganesha
  • Khairun University
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Ni Made WiratiniUniversitas Pendidikan Ganesha2
I Ketut BudiadaUniversitas Pendidikan Ganesha1
I Gusti Ayu Nyoman Sri WahyuniUniversitas Pendidikan Ganesha1
Indra CiptaKhairun University1
Khusna Arif RakhmanKhairun University1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OAI-PMH (metadata jurnal) https://jos.unsoed.ac.id/index.php/jm/oai, first harvested 9 Nov 2026, last seen 22 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US"> Carbon-Oxalate (C-Ox) Practicum Waste as an Adsorbent Material Candidate in the Chemistry Laboratory</dc:title>
	<dc:creator>Lasia, I Ketut</dc:creator>
	<dc:description xml:lang="en-US">This study aims to treat carbon and oxalate practicum waste as an adsorbent material candidate in the Chemistry Laboratory. Practicum waste was used to synthesise carbon-oxalate (C-Ox) by using wet (C-OxW) and semi-wet (C-OxDs) impregnation methods. The products were tested by SEM and FTIR. The adsorption was tested by contacting each 1 gram of C-Ox with various concentrations of chromium ions waste for 24 hours while shaking. The filtrate was measured by AAS. The data obtained were compared with standard activated carbon (CC) as control and analyzed with Freundlich and Langmuir isotherm equations. The results showed that C-Ox can be used as an adsorbent in the chemistry laboratory. Based on the SEM test, the pores of C-OxW were seen to be most than C-OxDs and CC. Adsorption of chromium ions of C-OxW and C-OxDs were more effective than CC. C-Ox test by FTIR showed very sharp wavenumbers appeared at 3674.5 and 3705.41 cm-1 for the hydroxyl groups; 1697.4 cm-1 for C=O; and 1141.8 cm-1 for C-O. The determination coefficient (R2) of Freundlich isotherm of CC and C-Ox were higher than Langmuir isotherm, and on the other hand, R2 of C-OxDs was shown oppositely.</dc:description>
	<dc:publisher xml:lang="en-US">Universitas Jenderal Soedirman</dc:publisher>
	<dc:date>2022-11-19</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://jos.unsoed.ac.id/index.php/jm/article/view/6463</dc:identifier>
	<dc:identifier>10.20884/1.jm.2022.17.3.6463</dc:identifier>
	<dc:source xml:lang="en-US">Molekul; Vol 17 No 3 (2022); 421-427</dc:source>
	<dc:source>2503-0310</dc:source>
	<dc:source>1907-9761</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://jos.unsoed.ac.id/index.php/jm/article/view/6463/3457</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2022 Molekul</dc:rights>