Melola Discovery

← Melola Discovery

Open access Journal SINTA 1

Well Integrity Study for CO2 WAG Application in Mature Field X, South Sumatra Area for the Fulfillment as CO2 Sequestration Sink

Scientific Contributions Oil and Gas · Vol. 44 No. 2 (2021) · pp. 107–121

DOI
10.29017/SCOG.44.2.587
ISSN
2541-0520, 2089-3361
Published
2021-08-30
Publisher
Testing Center for Oil and Gas LEMIGAS
Language
eng
License
creativecommons.org/licenses/by/4.0

Abstract

The most of today's global oil production comes from mature fields. Oil companies and governments are both concerned about increasing oil recovery from aging resources. To maintain oil production, the mature field must apply the Enhanced Oil Recovery method.  water-alternating-gas (WAG) injection is an enhanced oil recovery method designed to improve sweep efficiency during  injection with the injected water to control the mobility of. This study will discuss possible corrosion during  and water injection and the casing load calculation along with the production tubing during the injection phase. The following study also performed a suitable material selection for the best performance injection. This research was conducted by evaluating casing integrity for simulate  water-alternating-gas (WAG) to be applied in the X-well in the Y-field, South Sumatra, Indonesia. Corrosion prediction were performed using Electronic Corrosion Engineer (ECE®) corrosion model and for the strength of tubing which included burst, collapse, and tension of production casing was assessed using Microsoft Excel. This study concluded that for the casing load calculation results in 600 psi of burst pressure, collapse pressure of 2,555.64 psi, and tension of 190,528 lbf. All of these results are still following the K-55 production casing rating. While injecting, the maximum corrosion rate occurs. It has a maximum corrosion rate of 2.02 mm/year and a minimum corrosion rate of 0.36 mm/year. With this value, it is above NORSOK Standard M-001 which is 2 mm/year and needs to be evaluated to prevent the rate to remain stable and not decrease in the following years. To prevent the effect of maximum corrosion rate, the casing material must use a SM13CR (Martensitic Stainless Steel) which is not sour service material.

Keywords

Collaboration network of the authors

30 authors · 75 co-authorship links · 10 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Bandung Institute of Technology
  • Universitas Pembangunan Nasional Veteran Yogyakarta
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Brian TonyUniversitas Pembangunan Nasional Veteran Yogyakarta6
Mohammad RachmatBandung Institute of Technology3
Fanata Yudha NugrahaUniversitas Pembangunan Nasional Veteran Yogyakarta2
Damar NandiwardhanaUniversitas Pembangunan Nasional Veteran Yogyakarta2
Sudjati RachmatBandung Institute of Technology2
Ariel ParamastyaAffiliation unknown2
Mohammad Hafidz SetiawanAffiliation unknown2
Prasandi AAAffiliation unknown1
Amanda Efa DAffiliation unknown1
H T RonaldoAffiliation unknown1
Wijoyo N.D.Affiliation unknown1
Muhamad Firdaus Al HakimAffiliation unknown1
Muhammad Firdaus Al HakimUniversitas Pembangunan Nasional Veteran Yogyakarta1
Taufan MarhaendrajanaBandung Institute of Technology1
Tutuka AriadjiBandung Institute of Technology1
Utjok W.R. SiagianBandung Institute of Technology1
Bagus Endar B. NurhandokoBandung Institute of Technology1
Rafael J.S. PurbaAffiliation unknown1
Ega Dimas SaputraUniversitas Pembangunan Nasional Veteran Yogyakarta1
Muhammad Fadhlan SolihanBandung Institute of Technology1
Dedy IrawanBandung Institute of Technology1
SudonoAffiliation unknown1
Najeela Faza RamadhaniBandung Institute of Technology1
Dedy IrawanBandung Institute of Technology1
Syifa DestianaBandung Institute of Technology1
Ika MerdekawatiBandung Institute of Technology1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OAI-PMH (metadata jurnal) https://journal.lemigas.esdm.go.id/index.php/SCOG/oai, first harvested 10 Nov 2026, last seen 10 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">Well Integrity Study for CO2 WAG Application in Mature Field X, South Sumatra Area for the Fulfillment as CO2 Sequestration Sink</dc:title>
	<dc:creator xml:lang="en">Chandra, Steven</dc:creator>
	<dc:creator xml:lang="en">Aziz, Prasandi A</dc:creator>
	<dc:creator xml:lang="en">Naufal, Muhammad Raykhan</dc:creator>
	<dc:creator xml:lang="en">Daton, Wijoyo Niti</dc:creator>
	<dc:subject xml:lang="en">CO2 Water-Alternating-Gas (WAG)</dc:subject>
	<dc:subject xml:lang="en">Corrosion</dc:subject>
	<dc:subject xml:lang="en">Casing Load</dc:subject>
	<dc:description xml:lang="en">The most of today's global oil production comes from mature fields. Oil companies and governments are both concerned about increasing oil recovery from aging resources. To maintain oil production, the mature field must apply the Enhanced Oil Recovery method.  water-alternating-gas (WAG) injection is an enhanced oil recovery method designed to improve sweep efficiency during  injection with the injected water to control the mobility of . This study will discuss possible corrosion during  and water injection and the casing load calculation along with the production tubing during the injection phase. The following study also performed a suitable material selection for the best performance injection. This research was conducted by evaluating casing integrity for simulate  water-alternating-gas (WAG) to be applied in the X-well in the Y-field, South Sumatra, Indonesia. Corrosion prediction were performed using Electronic Corrosion Engineer (ECE®) corrosion model and for the strength of tubing which included burst, collapse, and tension of production casing was assessed using Microsoft Excel. This study concluded that for the casing load calculation results in 600 psi of burst pressure, collapse pressure of 2,555.64 psi, and tension of 190,528 lbf. All of these results are still following the K-55 production casing rating. While injecting , the maximum corrosion rate occurs. It has a maximum corrosion rate of 2.02 mm/year and a minimum corrosion rate of 0.36 mm/year. With this value, it is above NORSOK Standard M-001 which is 2 mm/year and needs to be evaluated to prevent the rate to remain stable and not decrease in the following years. To prevent the effect of maximum corrosion rate, the casing material must use a SM13CR (Martensitic Stainless Steel) which is not sour service material.</dc:description>
	<dc:publisher xml:lang="en">Testing Center for Oil and Gas LEMIGAS</dc:publisher>
	<dc:date>2021-08-30</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journal.lemigas.esdm.go.id/index.php/SCOG/article/view/587</dc:identifier>
	<dc:identifier>10.29017/SCOG.44.2.587</dc:identifier>
	<dc:source xml:lang="en">Scientific Contributions Oil and Gas; Vol. 44 No. 2 (2021); 107-121</dc:source>
	<dc:source xml:lang="id">Scientific Contributions Oil and Gas; Vol 44 No 2 (2021); 107-121</dc:source>
	<dc:source>2541-0520</dc:source>
	<dc:source>2089-3361</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://journal.lemigas.esdm.go.id/index.php/SCOG/article/view/587/325</dc:relation>
	<dc:rights xml:lang="en">Copyright (c) 2021 © Copyright by Authors. Published by LEMIGAS</dc:rights>
	<dc:rights xml:lang="en">https://creativecommons.org/licenses/by/4.0</dc:rights>
</oai_dc:dc>