Journal
SINTA 1
Kinerja Biosensor Konduktometri Berbasis (Screen Printed Carbon Electrode) SPCE––Kitosan untuk Deteksi Diazinon, Malation, Klorpirifos dan Profenofos
VALENSI · Vol. ume No. 2 (2015) · pp. 84–90
ISSN 2548-3013, 2460-6065
Published 2015-11-30
Publisher Department of Chemistry, Faculty of Science and Technology Syarif Hidayatullah Jakarta State Islamic University
Language eng
Abstract
The performance of biosensor is based on the hydrolysis reaction of organophosphorus compounds catalyzed by organophosphate hydrolase (OPH), produce H+ and the other ionic species that increase conductance on the surface of electrode. In this research, OPH was immobilized by crosslinking on chitosan–glutaraldehyde membrane on the (Screen Printed Carbon Electrode) SPCE surface. Measurements were carried out at the range concentration 0 to 3.0 ppm of organophosphate, the range of pH 7.0 to 9.0 and 5–25 mL of enzyme. The result showed that optimum performances were obtained at 25 mL of OPH, pH 8.5, with the sensitivity for dizinon, malathion, chlorpirifos and profenofos is 1.353 mS/ppm, 1.270 mS/ppm, 1.230 mS/ppm dan 1.77 mS/ppm respectively and 0.97; 1.03; 0.98; 0.97 of LOD. DOI:http://dx.doi.org/10.15408/jkv.v0i0.3156.
Collaboration network of the authors
13 authors ·
21 co-authorship links
Hover or tap a name to highlight its co-authors. Double-click to open the author's page.
Different organisations
Same organisation
Affiliation unknown
Thicker line = more joint articles · bigger circle = more articles
Show as table
Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.
Metadata source: OAI-PMH (metadata jurnal) http://journal.uinjkt.ac.id/index.php/valensi/oai, first harvested 10 Nov 2026, last seen 16 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en">Kinerja Biosensor Konduktometri Berbasis (Screen Printed Carbon Electrode) SPCE––Kitosan untuk Deteksi Diazinon, Malation, Klorpirifos dan Profenofos</dc:title>
<dc:creator xml:lang="en">Isvani, Nuzulul Kurniawan</dc:creator>
<dc:creator xml:lang="en">Mulyasuryani, Ani</dc:creator>
<dc:creator xml:lang="en">Prasetyawan, Sasangka</dc:creator>
<dc:subject xml:lang="en">Conductometric biosensor</dc:subject>
<dc:subject xml:lang="en">organophosphate pesticide</dc:subject>
<dc:subject xml:lang="en">organofosfat hydrolase</dc:subject>
<dc:subject xml:lang="en">SPCE (screen printed carbon electrode)</dc:subject>
<dc:description xml:lang="en">The performance of biosensor is based on the hydrolysis reaction of organophosphorus compounds catalyzed by organophosphate hydrolase (OPH), produce H+ and the other ionic species that increase conductance on the surface of electrode. In this research, OPH was immobilized by crosslinking on chitosan–glutaraldehyde membrane on the (Screen Printed Carbon Electrode) SPCE surface. Measurements were carried out at the range concentration 0 to 3.0 ppm of organophosphate, the range of pH 7.0 to 9.0 and 5–25 mL of enzyme. The result showed that optimum performances were obtained at 25 mL of OPH, pH 8.5, with the sensitivity for dizinon, malathion, chlorpirifos and profenofos is 1.353 mS/ppm, 1.270 mS/ppm, 1.230 mS/ppm dan 1.77 mS/ppm respectively and 0.97; 1.03; 0.98; 0.97 of LOD. DOI :http://dx.doi.org/10.15408/jkv.v0i0.3156. </dc:description>
<dc:publisher xml:lang="en">Department of Chemistry, Faculty of Science and Technology Syarif Hidayatullah Jakarta State Islamic University</dc:publisher>
<dc:date>2015-11-30</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://journal.uinjkt.ac.id/index.php/valensi/article/view/3156</dc:identifier>
<dc:identifier>10.15408/jkv.v0i0.3156</dc:identifier>
<dc:source xml:lang="en">Jurnal Kimia Valensi; Jurnal Kimia VALENSI Volume 1, No. 2, November 2015; 84-90</dc:source>
<dc:source>2548-3013</dc:source>
<dc:source>2460-6065</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://journal.uinjkt.ac.id/index.php/valensi/article/view/3156/pdf</dc:relation>
<dc:rights xml:lang="en">Copyright (c) 2019 Nuzulul Kurniawan Isvani, Ani Mulyasuryani, Sasangka Prasetyawan</dc:rights>
</oai_dc:dc>
Citations and indexing
OpenAlex
Indexed
via DOI
2 citations
Crossref
Indexed
via DOI
0 citations
Counts as reported by each index on 13 Nov 2026; indexes count citations differently.
OpenAlex also lists this work in: crossref, doaj.
Cite this article
APA 7
Isvani, N. K., Mulyasuryani, A., & Prasetyawan, S. (2015). Kinerja Biosensor Konduktometri Berbasis (Screen Printed Carbon Electrode) SPCE––Kitosan untuk Deteksi Diazinon, Malation, Klorpirifos dan Profenofos. VALENSI, ume(2), 84–90. https://doi.org/10.15408/jkv.v0i0.3156
Copy
IEEE
N. K. Isvani, A. Mulyasuryani, and S. Prasetyawan, “Kinerja Biosensor Konduktometri Berbasis (Screen Printed Carbon Electrode) SPCE––Kitosan untuk Deteksi Diazinon, Malation, Klorpirifos dan Profenofos,” VALENSI, vol. ume, no. 2, pp. 84–90, 2015, doi: 10.15408/jkv.v0i0.3156.
Copy
Generated from the journal's metadata; check author names before use.