Melola Discovery

← Melola Discovery

Journal SINTA 1

Comparative Study of Voltammetric Analysis with UV-Vis Spectrophotometry in Determining the Results of Liquid-Liquid Extraction of Samarium (III)

VALENSI · Vol. ume No. 2 (2024) · pp. 229–236

DOI
10.15408/jkv.v10i2.38941
ISSN
2548-3013, 2460-6065
Published
2024-12-16
Publisher
Department of Chemistry, Faculty of Science and Technology Syarif Hidayatullah Jakarta State Islamic University
Language
eng

Abstract

Rare earth elements (REEs) are garnering significant attention in diverse fields due to their important and fascinating properties. Among these REEs, samarium (Sm) has numerous advantages and benefits. Before using Sm, it must be separated from its natural sources due to the formation of complex compounds with other elements. To achieve this, liquid-liquid extraction emerges as one of the REE separation methods, presenting several advantages, including a streamlined process. Various methods can be used to analyze extraction results, such as ICP-MS and XRF. In comparison, UV-Vis spectrophotometry has significant advantages compared to other methods, it provides a simple approach to determining the level of a substance, and the results given are quite accurate, while differential pulse voltammetry (DPV) is one of the electrochemical analysis methods that is expected to provide faster and accurate analysis results. This study aims to determine the value of analytical parameters, Kd of Sm(III) liquid-liquid extraction results using DPV analysis and UV-Vis spectrophotometry methods. The DPV method yielded LoD 1.24 mg/L, accuracy 98.39%, and %recovery 106.69%. The extraction data obtained Kd Sm values ranging from 6.0019-7.3860. The UV-Vis spectrophotometry results provided an individual extraction efficiency of Sm(III) of 88.54%. This method obtained LoD 0.71 mg/L, accuracy 96.00%, and %recovery 104.00%.

Keywords

Collaboration network of the authors

36 authors · 135 co-authorship links · 1 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • International Islamic University Malaysia
  • Universitas Halu Oleo
  • Padjadjaran University
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Husein Hernandi BahtiAffiliation unknown5
Ari HardiantoAffiliation unknown4
Yeni Wahyuni HartatiAffiliation unknown4
Shauvina A ShauvinaAffiliation unknown2
Syulastri EffendiAffiliation unknown1
Abdul MutalibAffiliation unknown1
Abdul MutholibInternational Islamic University Malaysia1
Muhammad YusufUniversitas Halu Oleo1
Ratna Sari DewiAffiliation unknown1
Hesein H. BahtiAffiliation unknown1
Regaputra Satria JanitraAffiliation unknown1
Muhammad Ryan FauziAffiliation unknown1
Juliandri JuliandriAffiliation unknown1
Ukun Mochammad Syukur SoedjanaatmadjaAffiliation unknown1
Budi Nurani RuchjanaAffiliation unknown1
Atje Setiawan AbdullahPadjadjaran University1
Anggraeni AAffiliation unknown1
Nurdeni NurdeniAffiliation unknown1
Hardianto AAffiliation unknown1
Muthalib AAffiliation unknown1
Irwan KurniaAffiliation unknown1
Rudiawan EdwinAffiliation unknown1
Natasha FransiscaAffiliation unknown1
Zahra AfrianiAffiliation unknown1
Ayu Jelita SinambelaAffiliation unknown1
Nazwa Alya ZahraAffiliation unknown1
Nelson Indarto SuwarnoAffiliation unknown1
Husain Akbar SumeruAffiliation unknown1
Indah PrimadonaAffiliation unknown1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OAI-PMH (metadata jurnal) http://journal.uinjkt.ac.id/index.php/valensi/oai, first harvested 10 Nov 2026, last seen 10 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">Comparative Study of Voltammetric Analysis with UV-Vis Spectrophotometry in Determining the Results of Liquid-Liquid Extraction of Samarium (III)</dc:title>
	<dc:creator xml:lang="en">Wyantuti, Santhy</dc:creator>
	<dc:creator xml:lang="en">Nurwulanda, Salsha</dc:creator>
	<dc:creator xml:lang="en">Mardiah, Najmah</dc:creator>
	<dc:creator xml:lang="en">Anggraeni, Anni</dc:creator>
	<dc:creator xml:lang="en">Pratomo, Uji</dc:creator>
	<dc:creator xml:lang="en">Fauzia, Retna Putri</dc:creator>
	<dc:creator xml:lang="en">Bahti, Husein H.</dc:creator>
	<dc:subject xml:lang="en">Differential pulse voltammetry</dc:subject>
	<dc:subject xml:lang="en">liquid-liquid extraction</dc:subject>
	<dc:subject xml:lang="en">samarium</dc:subject>
	<dc:subject xml:lang="en">UV-Vis spectrophotometry</dc:subject>
	<dc:description xml:lang="en">Rare earth elements (REEs) are garnering significant attention in diverse fields due to their important and fascinating properties. Among these REEs, samarium (Sm) has numerous advantages and benefits. Before using Sm, it must be separated from its natural sources due to the formation of complex compounds with other elements. To achieve this, liquid-liquid extraction emerges as one of the REE separation methods, presenting several advantages, including a streamlined process. Various methods can be used to analyze extraction results, such as ICP-MS and XRF. In comparison, UV-Vis spectrophotometry has significant advantages compared to other methods, it provides a simple approach to determining the level of a substance, and the results given are quite accurate, while differential pulse voltammetry (DPV) is one of the electrochemical analysis methods that is expected to provide faster and accurate analysis results. This study aims to determine the value of analytical parameters, Kd of Sm(III) liquid-liquid extraction results using DPV analysis and UV-Vis spectrophotometry methods. The DPV method yielded LoD 1.24 mg/L,  accuracy 98.39%, and %recovery 106.69%. The extraction data obtained Kd Sm values ranging from 6.0019-7.3860. The UV-Vis spectrophotometry results provided an individual extraction efficiency of Sm(III) of 88.54%. This method obtained LoD 0.71 mg/L, accuracy 96.00%, and %recovery 104.00%.</dc:description>
	<dc:publisher xml:lang="en">Department of Chemistry, Faculty of Science and Technology Syarif Hidayatullah Jakarta State Islamic University</dc:publisher>
	<dc:date>2024-12-16</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journal.uinjkt.ac.id/index.php/valensi/article/view/38941</dc:identifier>
	<dc:identifier>10.15408/jkv.v10i2.38941</dc:identifier>
	<dc:source xml:lang="en">Jurnal Kimia Valensi; Jurnal Kimia VALENSI,  Volume 10, No. 2, November 2024; 229 - 236</dc:source>
	<dc:source>2548-3013</dc:source>
	<dc:source>2460-6065</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://journal.uinjkt.ac.id/index.php/valensi/article/view/38941/pdf</dc:relation>
	<dc:rights xml:lang="en">Copyright (c) 2024 Santhy Wyantuti</dc:rights>
</oai_dc:dc>