Abstract

In recent years, there is growth in acceptance to consume fewer fossil fuels globally and the manufacturing of electric vehicles (EVs) has become more popular. However, the increase in the number of systems connected to the grid that contain EVs with a huge power capacity leads to unstable working in the power system. To assess the stability of the electric charging station several control approaches in AC part and DC parts during charging mode and discharging modes are tested. African vulture optimization algorithm (AVOA) has been utilized to tune the system controllers (proportional integral derivative (PID)/tilt integral derivative (TID) controllers). The superiority of AVOA is confirmed by comparing the performance with the genetic algorithm (GA). Two objective functions have been used i.e. integral time absolute error (ITAE) and integral square time error (ISTE). AVOA-tuned TID controllers using ISTE were found to be the best to contain the frequency deviations. The results have shown of the AC part and DC part is within an acceptable limit recommended by IEEE standard. Further, maximum peak overshoot, undershoot, and settle time obtained by AVOA-tuned PID and TID controllers are found the best. Finally, the improvement of the performance index obtained by AVOA over its counterpart GA is confirmed.

Keywords

Collaboration network of the authors

35 authors · 108 co-authorship links · 70 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • University of Technology Malaysia
  • United Arab Emirates University
  • Western Sydney University
  • National University of Malaysia
  • Jubail Industrial College
  • Islamic University of Madinah
  • Islamia University of Bahawalpur
  • Other organisations
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Madathodika AsnaUnited Arab Emirates University4
Md Mainul IslamWestern Sydney University2
Mahmood H. NagrialWestern Sydney University2
Jamal RizkWestern Sydney University2
Ali HellanyWestern Sydney University2
Bashar Abdullah HamadNorthern Technical University2
A. Al DosariUnited Arab Emirates University2
Mohamed Shaker AlhammadiUnited Arab Emirates University2
Nasser AldarmakiUnited Arab Emirates University2
A. O. IdrisAffiliation unknown2
A. N. AldarmakiUnited Arab Emirates University2
Basil HamedUnited Arab Emirates University2
Tole SutiknoUniversitas Ahmad Dahlan1
Awang JusohUniversity of Technology Malaysia1
Muhammad AdoUniversity of Technology Malaysia1
Mohd Hanipah MudaTATI University College1
Aliyu Hamza SuleUniversity of Technology Malaysia1
Jasrul Jamani Bin JamianUniversity of Technology Malaysia1
Attaullah KhidraniBalochistan University of Engineering and Technology1
Raja Masood LarikNED University of Engineering and Technology1
Usman Ullah SheikhUniversity of Technology Malaysia1
Farrukh HafeezUniversity of Technology Malaysia1
Saud J. Al-ShammariJubail Industrial College1
Muhammad HamidCommunity College of Qatar1
Abdul Baqi Khan KhakwaniJubail Industrial College1
Azah MohamedNational University of Malaysia1
Khairuddin KhalidNational University of Malaysia1
Ramizi MohamedNational University of Malaysia1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, first harvested 19 Nov 2026, last seen 19 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Improve power quality of charging station unit using African vulture optimization algorithm</dc:title><dc:creator>Saleh Masoud Abdallah Altbawi</dc:creator><dc:creator>S.N. Khalid</dc:creator><dc:creator>Ahmad Safawi Mokhtar</dc:creator><dc:creator>Rayan Hamza Alsisi</dc:creator><dc:creator>Zeeshan Ahmad Arfeen</dc:creator><dc:creator>Hussain Shareef</dc:creator><dc:creator>Mehreen Kausar Azam</dc:creator><dc:subject>power quality</dc:subject><dc:subject>electric vehicle charging stations</dc:subject><dc:subject>African vulture optimization algorithm</dc:subject><dc:subject>PID controller tuning</dc:subject><dc:subject>tilt-integral-derivative controller</dc:subject><dc:subject>frequency deviation</dc:subject><dc:subject>controller tuning</dc:subject><dc:subject>genetic algorithm comparison</dc:subject><dc:subject>integral time absolute error</dc:subject><dc:description xml:lang="en">In recent years, there is growth in acceptance to consume fewer fossil fuels globally and the manufacturing of electric vehicles (EVs) has become more popular. However, the increase in the number of systems connected to the grid that contain EVs with a huge power capacity leads to unstable working in the power system. To assess the stability of the electric charging station several control approaches in AC part and DC parts during charging mode and discharging modes are tested. African vulture optimization algorithm (AVOA) has been utilized to tune the system controllers (proportional integral derivative (PID)/tilt integral derivative (TID) controllers). The superiority of AVOA is confirmed by comparing the performance with the genetic algorithm (GA). Two objective functions have been used i.e. integral time absolute error (ITAE) and integral square time error (ISTE). AVOA-tuned TID controllers using ISTE were found to be the best to contain the frequency deviations. The results have shown of the AC part and DC part is within an acceptable limit recommended by IEEE standard. Further, maximum peak overshoot, undershoot, and settle time obtained by AVOA-tuned PID and TID controllers are found the best. Finally, the improvement of the performance index obtained by AVOA over its counterpart GA is confirmed.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2023-06-19</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v12i5.5717</dc:identifier><dc:identifier>10.11591/eei.v12i5.5717</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 12 No 5 (2023); 2605-2614</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/5717/3369</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>