Melola Discovery

← Melola Discovery

Journal SINTA 1

Food intake gesture monitoring system based-on depth sensor

Bulletin of Electrical Engineering and Informatics · Vol. 8 No. 2 (2019) · pp. 470–476

DOI
10.11591/eei.v8i2.1424
ISSN
2089-3191, 2302-9285
Published
2019-06-01
Publisher
Institute of Advanced Engineering and Science (IAES)
Language
en

Abstract

Food intake gesture technology is one of a new strategy for obesity people managing their health care while saving their time and money. This approach involves combining face and hand joint point for monitoring food intake of a user using Kinect Xbox One camera sensor. Rather than counting calories, scientists at Brigham Young University found dieters who eager to reduce their number of daily bites by 20 to 30 percent lost around two kilograms a month, regardless of what they ate [1]. Research studies showed that most of the methods used to count bite are worn type devices which has high false alarm ratio. Today trend is going toward the non-wearable device. This sensor is used to capture skeletal data of user while eating and train the data to capture the motion and movement while eating. There are specific joint to be capture such as Jaw face point and wrist roll joint. Overall accuracy is around 94%. Basically, this increase in the overall recognition rate of this system.

Keywords

Collaboration network of the authors

14 authors · 34 co-authorship links · 7 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Tun Hussein Onn University of Malaysia
  • University of Technology Malaysia
  • Universiti Teknikal Malaysia Melaka
  • University of Technology and Applied Sciences-Nizwa
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Razali TomariTun Hussein Onn University of Malaysia3
Wan Nurshazwani Wan ZakariaTun Hussein Onn University of Malaysia3
Nor Surayahani SurianiTun Hussein Onn University of Malaysia3
Usman Ullah SheikhUniversity of Technology Malaysia2
Suhaila SariTun Hussein Onn University of Malaysia2
Fawad Salam KhanTun Hussein Onn University of Malaysia1
Muhammad Inam AbbasiUniversiti Teknikal Malaysia Melaka1
Muhammad KhurramUniversity of Technology and Applied Sciences-Nizwa1
Muhammad Danial KhanAffiliation unknown1
Syadia Nabilah Mohd SafuanTun Hussein Onn University of Malaysia1
Aymen Fadhil AbbasUniversity of Technology Malaysia1
Tay Eng LiangAffiliation unknown1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, first harvested 19 Nov 2026, last seen 19 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Food intake gesture monitoring system based-on depth sensor</dc:title><dc:creator>Muhammad Fuad bin Kassim</dc:creator><dc:creator>Mohd Norzali Haji Mohd</dc:creator><dc:subject>dietary monitoring</dc:subject><dc:subject>gesture recognition</dc:subject><dc:subject>depth sensors</dc:subject><dc:subject>Kinect sensor</dc:subject><dc:subject>obesity</dc:subject><dc:subject>skeleton tracking</dc:subject><dc:description xml:lang="en">Food intake gesture technology is one of a new strategy for obesity people managing their health care while saving their time and money. This approach involves combining face and hand joint point for monitoring food intake of a user using Kinect Xbox One camera sensor. Rather than counting calories, scientists at Brigham Young University found dieters who eager to reduce their number of daily bites by 20 to 30 percent lost around two kilograms a month, regardless of what they ate [1]. Research studies showed that most of the methods used to count bite are worn type devices which has high false alarm ratio. Today trend is going toward the non-wearable device. This sensor is used to capture skeletal data of user while eating and train the data to capture the motion and movement while eating. There are specific joint to be capture such as Jaw face point and wrist roll joint. Overall accuracy is around 94%. Basically, this increase in the overall recognition rate of this system.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2019-06-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v8i2.1424</dc:identifier><dc:identifier>10.11591/eei.v8i2.1424</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 8 No 2 (2019); 470-476</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/1424/1054</dc:relation></oai_dc:dc>