Abstract

This article uses a dynamic voltage restorer to tackle a wide range of power quality issues, such as voltage drooping and swelling, spikes, distortions, and so on. The proportional controller, integrated controller (PI), and adaptive neuro-fuzzy inference system (ANFIS) are proposed dynamic voltage restorer (DVR) controllers. The control strategy's goal is to employ an injection transformer to mitigate for the needed voltage and keep the load voltage fixed. The settings of the PI controller are fine-tuned using two methods: trial and error and intelligent optimum. Particle swarm optimization (PSO) is now the most effective method. In terms of settling time, overshoot, undershoot, and disturbances around the final value, the PSO-tuned PI controller outperforms the trial-and-error PI controller. The ANFIS controller is used to regulate the DVR's responsiveness through the PI-PSO controller. The PI-PSO data is used as training data by the ANFIS controller. The results show that a DVR with an ANFIS controller outperforms a PI-PSO controller in terms of overshoot, undershoot spike voltage, steady state time, and settling time. In the case of a failure voltage, the DVR with an ANFIS controller has a 27% undershoot spike voltage while the PI-PSO controller has a 30% undershoot spike voltage.

Keywords

Collaboration network of the authors

9 authors · 13 co-authorship links

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • University of Technology - Iraq
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Nihad Mohammed AmeenAffiliation unknown2
Hayder Yousif AbedAffiliation unknown1
Amjad J. HumaidiUniversity of Technology - Iraq1
Abbas Hussain IssaAffiliation unknown1
Sarab A. MahmoodAffiliation unknown1
Lina J. RashadAffiliation unknown1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, first harvested 22 Nov 2026, last seen 22 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Dynamic voltage restorer based on particle swarm optimization algorithm and adaptive neuro-fuzzy inference system</dc:title><dc:creator>Saddam Subhi Salman</dc:creator><dc:creator>Abdulrahim Thiab Humod</dc:creator><dc:creator>Fadhil A. Hasan</dc:creator><dc:subject>dynamic voltage restorer</dc:subject><dc:subject>power quality</dc:subject><dc:subject>voltage sag and swell</dc:subject><dc:subject>voltage spikes</dc:subject><dc:subject>voltage distortion</dc:subject><dc:subject>particle swarm optimization</dc:subject><dc:subject>adaptive neuro-fuzzy inference system</dc:subject><dc:subject>PI controller tuning</dc:subject><dc:subject>injection transformer</dc:subject><dc:description xml:lang="en">This article uses a dynamic voltage restorer to tackle a wide range of power quality issues, such as voltage drooping and swelling, spikes, distortions, and so on. The proportional controller, integrated controller (PI), and adaptive neuro-fuzzy inference system (ANFIS) are proposed dynamic voltage restorer (DVR) controllers. The control strategy's goal is to employ an injection transformer to mitigate for the needed voltage and keep the load voltage fixed. The settings of the PI controller are fine-tuned using two methods: trial and error and intelligent optimum. Particle swarm optimization (PSO) is now the most effective method. In terms of settling time, overshoot, undershoot, and disturbances around the final value, the PSO-tuned PI controller outperforms the trial-and-error PI controller. The ANFIS controller is used to regulate the DVR's responsiveness through the PI-PSO controller. The PI-PSO data is used as training data by the ANFIS controller. The results show that a DVR with an ANFIS controller outperforms a PI-PSO controller in terms of overshoot, undershoot spike voltage, steady state time, and settling time. In the case of a failure voltage, the DVR with an ANFIS controller has a 27% undershoot spike voltage while the PI-PSO controller has a 30% undershoot spike voltage.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2022-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v11i6.4023</dc:identifier><dc:identifier>10.11591/eei.v11i6.4023</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 11 No 6 (2022); 3217-3227</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/4023/2990</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>