Open access
Journal
SINTA 1
Faults detection, location, and classification of the elements in the power system using intelligent algorithm
Bulletin of Electrical Engineering and Informatics · Vol. 12 No. 2 (2023) · pp. 597–607
ISSN 2089-3191, 2302-9285
Published 2023-04-01
Publisher Institute of Advanced Engineering and Science (IAES)
Language en
Abstract
This study proposes an intelligent protection relay design that uses artificial neural networks to secure electrical parts in power infrastructure from different faults. Electrical transformer and transmission lines are protected using intelligent differential and distance relay, respectively. Faults are categorized, and their locations are pinpointed using three-phase current values and zero-current characteristics to differentiate between non-earth and ground faults. The optimal aspects of the artificial neural network were chosen for optimal results with the least possible error. Levenberg-Marquardt was established as the ideal training technique for the suggested system comprising the differential relay. Levenberg-Marquardt was the optimal training technique for the proposed framework consisting of the differential relay. Fault detection and categorization were performed using 20 and 50 hidden layers, and the corresponding error rates were 9.9873e-3 and 1.1953e-29. In the context of fault detection by the distance relay, the hidden layer neuron counts were 400, 250, and 300 for fault detection, categorization, and location; training error rates were 7.8761e-2, 1.2063e-6, and 1.1616e-26, respectively.
Collaboration network of the authors
14 authors ·
21 co-authorship links
· 7 across different organisations
Hover or tap a name to highlight its co-authors. Double-click to open the author's page.
University of Mosul Universiti Sains Malaysia University of Technology Malaysia Affiliation unknown
Different organisations
Same organisation
Affiliation unknown
Thicker line = more joint articles · bigger circle = more articles
Show as table
Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.
Metadata source: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, first harvested 22 Nov 2026, last seen 22 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Faults detection, location, and classification of the elements in the power system using intelligent algorithm</dc:title><dc:creator>Ali Abbawi</dc:creator><dc:creator>Ibrahim Ismael Alnaib</dc:creator><dc:creator>Omar Sh. Alyozbaky</dc:creator><dc:creator>Karam Khairullah Mohammed</dc:creator><dc:subject>power system fault detection</dc:subject><dc:subject>fault location</dc:subject><dc:subject>fault classification</dc:subject><dc:subject>artificial neural networks</dc:subject><dc:subject>differential relay</dc:subject><dc:subject>distance relays</dc:subject><dc:subject>transformer protection</dc:subject><dc:subject>transmission line protection</dc:subject><dc:subject>zero-sequence current</dc:subject><dc:subject>Levenberg-Marquardt training</dc:subject><dc:subject>hidden layer optimization</dc:subject><dc:description xml:lang="en">This study proposes an intelligent protection relay design that uses artificial neural networks to secure electrical parts in power infrastructure from different faults. Electrical transformer and transmission lines are protected using intelligent differential and distance relay, respectively. Faults are categorized, and their locations are pinpointed using three-phase current values and zero-current characteristics to differentiate between non-earth and ground faults. The optimal aspects of the artificial neural network were chosen for optimal results with the least possible error. Levenberg-Marquardt was established as the ideal training technique for the suggested system comprising the differential relay. Levenberg-Marquardt was the optimal training technique for the proposed framework consisting of the differential relay. Fault detection and categorization were performed using 20 and 50 hidden layers, and the corresponding error rates were 9.9873e-3 and 1.1953e-29. In the context of fault detection by the distance relay, the hidden layer neuron counts were 400, 250, and 300 for fault detection, categorization, and location; training error rates were 7.8761e-2, 1.2063e-6, and 1.1616e-26, respectively.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2023-04-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v12i2.4456</dc:identifier><dc:identifier>10.11591/eei.v12i2.4456</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 12 No 2 (2023); 597-607</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/4456/3123</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>
Citations and indexing
OpenAlex
Indexed
via ID karya OpenAlex (record dari sumber OpenAlex)
13 citations
Crossref
Indexed
via DOI
6 citations
Counts as reported by each index on 19 Nov 2026; indexes count citations differently.
OpenAlex also lists this work in: crossref.
Cite this article
APA 7
Abbawi, A., Alnaib, I. I., Alyozbaky, O. S., & Mohammed, K. K. (2023). Faults detection, location, and classification of the elements in the power system using intelligent algorithm. Bulletin of Electrical Engineering and Informatics, 12(2), 597–607. https://doi.org/10.11591/eei.v12i2.4456
Copy
IEEE
A. Abbawi, I. I. Alnaib, O. S. Alyozbaky, and K. K. Mohammed, “Faults detection, location, and classification of the elements in the power system using intelligent algorithm,” Bulletin of Electrical Engineering and Informatics, vol. 12, no. 2, pp. 597–607, 2023, doi: 10.11591/eei.v12i2.4456.
Copy
Generated from the journal's metadata; check author names before use.