Abstract

This study proposes an intelligent protection relay design that uses artificial neural networks to secure electrical parts in power infrastructure from different faults. Electrical transformer and transmission lines are protected using intelligent differential and distance relay, respectively. Faults are categorized, and their locations are pinpointed using three-phase current values and zero-current characteristics to differentiate between non-earth and ground faults. The optimal aspects of the artificial neural network were chosen for optimal results with the least possible error. Levenberg-Marquardt was established as the ideal training technique for the suggested system comprising the differential relay. Levenberg-Marquardt was the optimal training technique for the proposed framework consisting of the differential relay. Fault detection and categorization were performed using 20 and 50 hidden layers, and the corresponding error rates were 9.9873e-3 and 1.1953e-29. In the context of fault detection by the distance relay, the hidden layer neuron counts were 400, 250, and 300 for fault detection, categorization, and location; training error rates were 7.8761e-2, 1.2063e-6, and 1.1616e-26, respectively.

Keywords

Collaboration network of the authors

14 authors · 21 co-authorship links · 7 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • University of Mosul
  • Universiti Sains Malaysia
  • University of Technology Malaysia
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Wisam NajemUniversity of Mosul1
Shaker Mahmood KhudherUniversity of Mosul1
Ibrahim IsmaeelAffiliation unknown1
Sa’ad Ahmed Saleh Al KazzazUniversity of Mosul1
Mustafa AljammalUniversity of Mosul1
Anas MustafaUniversity of Mosul1
Hiba Nadhim A. Al-KaoazUniversity of Mosul1
Mohd Fadzil AinUniversiti Sains Malaysia1
Mohamad Kamarol Mohd JamilUniversiti Sains Malaysia1
Mazyed A. Al-TakUniversiti Sains Malaysia1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, first harvested 22 Nov 2026, last seen 22 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Faults detection, location, and classification of the elements in the power system using intelligent algorithm</dc:title><dc:creator>Ali Abbawi</dc:creator><dc:creator>Ibrahim Ismael Alnaib</dc:creator><dc:creator>Omar Sh. Alyozbaky</dc:creator><dc:creator>Karam Khairullah Mohammed</dc:creator><dc:subject>power system fault detection</dc:subject><dc:subject>fault location</dc:subject><dc:subject>fault classification</dc:subject><dc:subject>artificial neural networks</dc:subject><dc:subject>differential relay</dc:subject><dc:subject>distance relays</dc:subject><dc:subject>transformer protection</dc:subject><dc:subject>transmission line protection</dc:subject><dc:subject>zero-sequence current</dc:subject><dc:subject>Levenberg-Marquardt training</dc:subject><dc:subject>hidden layer optimization</dc:subject><dc:description xml:lang="en">This study proposes an intelligent protection relay design that uses artificial neural networks to secure electrical parts in power infrastructure from different faults. Electrical transformer and transmission lines are protected using intelligent differential and distance relay, respectively. Faults are categorized, and their locations are pinpointed using three-phase current values and zero-current characteristics to differentiate between non-earth and ground faults. The optimal aspects of the artificial neural network were chosen for optimal results with the least possible error. Levenberg-Marquardt was established as the ideal training technique for the suggested system comprising the differential relay. Levenberg-Marquardt was the optimal training technique for the proposed framework consisting of the differential relay. Fault detection and categorization were performed using 20 and 50 hidden layers, and the corresponding error rates were 9.9873e-3 and 1.1953e-29. In the context of fault detection by the distance relay, the hidden layer neuron counts were 400, 250, and 300 for fault detection, categorization, and location; training error rates were 7.8761e-2, 1.2063e-6, and 1.1616e-26, respectively.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2023-04-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v12i2.4456</dc:identifier><dc:identifier>10.11591/eei.v12i2.4456</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 12 No 2 (2023); 597-607</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/4456/3123</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>