Abstract

In electric drive control systems, the main goal is to maintain the driving motor speed to meet the mechanism’s requirements. In some practical industrial applications the mechanically-coupled load to the motor shaft has a varying mass during the system operation. Therefore, the change of mass changes the value of the moment of inertia of the system. The moment of inertia impacts the system operation, particularly the transient performance. Therefore, the variation of moment of inertia on the motor shaft during its operation creates additional challenges to accomplish a high-quality speed control. The main purpose of the current work is to study the impact of the variation of moment of inertia on the performance of both AC and DC electric drive control systems and to make a comparison between them. A mathematical analysis and simulations of the control system models had been presented; one time with three-phase induction motor and another time with DC motor, both with variable moment of inertia. A simulation of both systems had been accomplished using the Simulink software in MATLAB. The simulation results of operation of these systems have been analysed in order to get useful conclusions and recommendations for the electric drive control system designer.

Keywords

Collaboration network of the authors

9 authors · 14 co-authorship links · 3 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Tafila Technical University
  • Admiral Makarov National University of Shipbuilding
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Mahmoud M. S. Al-SuodTafila Technical University2
Alaa Al-QuteimatTafila Technical University2
Oleksandr UshkarenkoAdmiral Makarov National University of Shipbuilding2
Aouda ArfoaTafila Technical University1
Sadam Al-MashakbehTafila Technical University1
Atef Saleh Al-MashakbehTafila Technical University1
Ali S. AkaylehTafila Technical University1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, first harvested 22 Nov 2026, last seen 22 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">A comparative study of performance of AC and DC electric drive control systems with variable moment of inertia</dc:title><dc:creator>Emad Said Addasi</dc:creator><dc:creator>Abdullah Eial Awwad</dc:creator><dc:subject>electric drive control system</dc:subject><dc:subject>variable moment of inertia</dc:subject><dc:subject>AC motor drives</dc:subject><dc:subject>DC motor drive</dc:subject><dc:subject>three-phase induction motor</dc:subject><dc:subject>DC motor</dc:subject><dc:subject>speed control</dc:subject><dc:subject>transient performance</dc:subject><dc:description xml:lang="en">In electric drive control systems, the main goal is to maintain the driving motor speed to meet the mechanism’s requirements. In some practical industrial applications the mechanically-coupled load to the motor shaft has a varying mass during the system operation. Therefore, the change of mass changes the value of the moment of inertia of the system. The moment of inertia impacts the system operation, particularly the transient performance. Therefore, the variation of moment of inertia on the motor shaft during its operation creates additional challenges to accomplish a high-quality speed control. The main purpose of the current work is to study the impact of the variation of moment of inertia on the performance of both AC and DC electric drive control systems and to make a comparison between them. A mathematical analysis and simulations of the control system models had been presented; one time with three-phase induction motor and another time with DC motor, both with variable moment of inertia. A simulation of both systems had been accomplished using the Simulink software in MATLAB. The simulation results of operation of these systems have been analysed in order to get useful conclusions and recommendations for the electric drive control system designer.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2021-04-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v10i2.2768</dc:identifier><dc:identifier>10.11591/eei.v10i2.2768</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 10 No 2 (2021); 588-597</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/2768/2104</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>