Melola Discovery

← Melola Discovery

Open access Journal SINTA 1

Design of a novel control hysteresis algorithm for photovoltaic systems for harmonic compensation

Bulletin of Electrical Engineering and Informatics · Vol. 13 No. 1 (2024) · pp. 31–37

DOI
10.11591/eei.v13i1.6038
ISSN
2089-3191, 2302-9285
Published
2024-02-01
Publisher
Institute of Advanced Engineering and Science (IAES)
Language
en
License
creativecommons.org/licenses/by-sa/4.0/

Abstract

Solar photovoltaic (PV) system design and integration with an existing AC grid is growing very fast in recent years and used by many of them as they are pollution-free, structure is limited and maintenance free. From the factors considering, the performance of PV system depends upon the inverter output voltage tested for linear, non-linear, with harmonic, and without harmonic loads. Generated due to the nonlinear loads. Better inverter control techniques are developed to maintain grid power quality. This article discusses the analysis and comparison of pulse width modulation (PWM) converters with unique and state of the art nonlinear control schemes and various modulation approaches. The primary objective of this research is controlling an active filtering hysteresis PWM converter with no sensors. A simple structure with hysteresis current control method total harmonic distortion (THD) is lower when compared with the sinusoidal pulse width modulation (SPWM) method. The said claims are supported by employing computer simulations using MATLAB/Simulink and different control approaches, such as proportional plus integral and artificial neural network controllers.

Keywords

Collaboration network of the authors

6 authors · 9 co-authorship links

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • National Institute of Technology Andhra Pradesh
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
K. Sree LathaAffiliation unknown2
Gaurav GauravNational Institute of Technology Andhra Pradesh1
Jayaram NakkaNational Institute of Technology Andhra Pradesh1
Sairaj ArandhakarNational Institute of Technology Andhra Pradesh1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, first harvested 22 Nov 2026, last seen 22 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Design of a novel control hysteresis algorithm for photovoltaic systems for harmonic compensation</dc:title><dc:creator>Dakka Obulesu</dc:creator><dc:creator>Malladi Lakshmi Swarupa</dc:creator><dc:subject>photovoltaic systems</dc:subject><dc:subject>hysteresis current control</dc:subject><dc:subject>harmonic compensation</dc:subject><dc:subject>active filtering</dc:subject><dc:subject>pulse width modulation</dc:subject><dc:subject>total harmonic distortion</dc:subject><dc:subject>nonlinear loads</dc:subject><dc:subject>grid power quality</dc:subject><dc:subject>neural network control</dc:subject><dc:subject>PI controller</dc:subject><dc:description xml:lang="en">Solar photovoltaic (PV) system design and integration with an existing AC grid is growing very fast in recent years and used by many of them as they are pollution-free, structure is limited and maintenance free. From the factors considering, the performance of PV system depends upon the inverter output voltage tested for linear, non-linear, with harmonic, and without harmonic loads. Generated due to the nonlinear loads. Better inverter control techniques are developed to maintain grid power quality. This article discusses the analysis and comparison of pulse width modulation (PWM) converters with unique and state of the art nonlinear control schemes and various modulation approaches. The primary objective of this research is controlling an active filtering hysteresis PWM converter with no sensors. A simple structure with hysteresis current control method total harmonic distortion (THD) is lower when compared with the sinusoidal pulse width modulation (SPWM) method. The said claims are supported by employing computer simulations using MATLAB/Simulink and different control approaches, such as proportional plus integral and artificial neural network controllers.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2024-02-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v13i1.6038</dc:identifier><dc:identifier>10.11591/eei.v13i1.6038</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 13 No 1 (2024); 31-37</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/6038/3513</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>