Melola Discovery

← Melola Discovery

Open access Journal SINTA 1

Design of a secure-cloud remote medical monitoring system using the P-QRS-T electrocardiogram detection algorithm

Bulletin of Electrical Engineering and Informatics · Vol. 14 No. 6 (2025) · pp. 4743–4757

DOI
10.11591/eei.v14i6.10730
ISSN
2089-3191, 2302-9285
Published
2025-12-01
Publisher
Institute of Advanced Engineering and Science (IAES)
Language
en
License
creativecommons.org/licenses/by-sa/4.0/

Abstract

The COVID-19 pandemic has highlighted the limitations of traditional healthcare, resulting in higher mortality rates among children, the elderly, and healthcare workers. This situation has created a pressing need for urgent medical care from healthcare professionals. This paper presents a secure cloud-based remote medical monitoring system that integrates the internet of things (RMMS-IoT) with advanced P-QRS-T electrocardiogram (ECG) detection algorithms to enable real-time, accurate vital sign analysis. The system combines microcontroller devices, wearable sensors, and medical-grade equipment, leveraging hypertext transfer protocol secure (HTTPS) and Blynk bridge cloud technologies to ensure data security and interoperability. The RMMS-IoT system demonstrated high accuracy in monitoring vital signs by comparing its results with data from actual measuring devices, showing errors in body temperature readings below 1% and heart rate (HR) measurements below 2.8%. The algorithm used to detect P-QRS-T features from the ECG exhibited robust performance in differentiating between normal and abnormal ECG patterns in patients, and it achieved an accuracy rate of 90% in ECG classification.

Keywords

Collaboration network of the authors

3 authors · 3 co-authorship links

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Larbi Ben M'hidi University of Oum El Bouaghi
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, first harvested 19 Nov 2026, last seen 22 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Design of a secure-cloud remote medical monitoring system using the P-QRS-T electrocardiogram detection algorithm</dc:title><dc:creator>Rostom Khalef</dc:creator><dc:creator>Fateh Moulahcene</dc:creator><dc:creator>Ammar Merazga</dc:creator><dc:subject>remote patient monitoring</dc:subject><dc:subject>cloud-based healthcare</dc:subject><dc:subject>ECG classification</dc:subject><dc:subject>Internet of Things</dc:subject><dc:subject>wearable sensors</dc:subject><dc:subject>vital signs monitoring</dc:subject><dc:subject>HTTPS</dc:subject><dc:subject>Blynk</dc:subject><dc:subject>data security</dc:subject><dc:subject>heart rate measurement</dc:subject><dc:subject>body temperature measurement</dc:subject><dc:subject>COVID-19 pandemic</dc:subject><dc:description xml:lang="en">The COVID-19 pandemic has highlighted the limitations of traditional healthcare, resulting in higher mortality rates among children, the elderly, and healthcare workers. This situation has created a pressing need for urgent medical care from healthcare professionals. This paper presents a secure cloud-based remote medical monitoring system that integrates the internet of things (RMMS-IoT) with advanced P-QRS-T electrocardiogram (ECG) detection algorithms to enable real-time, accurate vital sign analysis. The system combines microcontroller devices, wearable sensors, and medical-grade equipment, leveraging hypertext transfer protocol secure (HTTPS) and Blynk bridge cloud technologies to ensure data security and interoperability. The RMMS-IoT system demonstrated high accuracy in monitoring vital signs by comparing its results with data from actual measuring devices, showing errors in body temperature readings below 1% and heart rate (HR) measurements below 2.8%. The algorithm used to detect P-QRS-T features from the ECG exhibited robust performance in differentiating between normal and abnormal ECG patterns in patients, and it achieved an accuracy rate of 90% in ECG classification.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2025-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v14i6.10730</dc:identifier><dc:identifier>10.11591/eei.v14i6.10730</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 14 No 6 (2025); 4743-4757</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/10730/4492</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>