Melola Discovery

← Melola Discovery

Journal SINTA 1

Design and development of sensorless based 5-DOF bilaterally controlled surgical manipulator: A prototype

Bulletin of Electrical Engineering and Informatics · Vol. 10 No. 2 (2021) · pp. 619–631

DOI
10.11591/eei.v10i2.2331
ISSN
2089-3191, 2302-9285
Published
2021-04-01
Publisher
Institute of Advanced Engineering and Science (IAES)
Language
en

Abstract

Minimally invasive surgery (MIS) is one of the most challenging tasks in surgical procedures due to the lack of visibility of the surgical area, instrument orientation, and depth perception. A tele-operated robot assisted minimally invasive surgery is developed to enhance a surgeon's hand dexterity and accuracy. To perform MIS, the surgeon controls a slave manipulator via a master manipulator, so the force feedback and motion feedback are required to imitate an amount of action and reaction force between master and slave manipulator. The complicated MIS requires more complex surgical manipulator with multi DOFs and multiple force feedback. The limitation of multiple DOFs force feedback is a bandwidth of torque sensors. Therefore, this study proposes a sensorless based 5-DOF Bilaterally controlled surgical manipulation. In this research disturbance observer (DOB) is used to identify the internal disturbance of the system, which is used to estimate the reaction torque. This research mainly focuses on a 5-DOF bilaterally controlled surgical manipulator to maintain a position and additional force. The result of torque error in contact motion is less than 2%, the non-contact motion error is not over 5%, and it is evident that the error is always less than 0.3% for the position response.

Keywords

Collaboration network of the authors

10 authors · 16 co-authorship links

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Mahidol University
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Preedipat SattayasoonthornMahidol University2
Chumpon WilasrusmeeMahidol University2
Nantida NillahootMahidol University2
Sorayouth ChumnanvejMahidol University2
Sorayouth ChamnanvejMahidol University1
Sorayouth Chamnanvej M.DAffiliation unknown1
Chawaphol DirekwatanaMahidol University1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, first harvested 22 Nov 2026, last seen 22 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Design and development of sensorless based 5-DOF bilaterally controlled surgical manipulator: A prototype</dc:title><dc:creator>Sakol Nakdhamabhorn</dc:creator><dc:creator>Branesh Madhavan Pillai</dc:creator><dc:creator>Jackrit Suthakorn</dc:creator><dc:subject>sensorless control</dc:subject><dc:subject>bilateral control</dc:subject><dc:subject>surgical manipulator</dc:subject><dc:subject>teleoperation</dc:subject><dc:subject>minimally invasive surgery</dc:subject><dc:subject>disturbance observer</dc:subject><dc:subject>force feedback</dc:subject><dc:subject>5-DOF manipulator</dc:subject><dc:subject>master-slave teleoperation</dc:subject><dc:description xml:lang="en">Minimally invasive surgery (MIS) is one of the most challenging tasks in surgical procedures due to the lack of visibility of the surgical area, instrument orientation, and depth perception. A tele-operated robot assisted minimally invasive surgery is developed to enhance a surgeon's hand dexterity and accuracy. To perform MIS, the surgeon controls a slave manipulator via a master manipulator, so the force feedback and motion feedback are required to imitate an amount of action and reaction force between master and slave manipulator. The complicated MIS requires more complex surgical manipulator with multi DOFs and multiple force feedback. The limitation of multiple DOFs force feedback is a bandwidth of torque sensors. Therefore, this study proposes a sensorless based 5-DOF Bilaterally controlled surgical manipulation. In this research disturbance observer (DOB) is used to identify the internal disturbance of the system, which is used to estimate the reaction torque. This research mainly focuses on a 5-DOF bilaterally controlled surgical manipulator to maintain a position and additional force. The result of torque error in contact motion is less than 2%, the non-contact motion error is not over 5%, and it is evident that the error is always less than 0.3% for the position response.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2021-04-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v10i2.2331</dc:identifier><dc:identifier>10.11591/eei.v10i2.2331</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 10 No 2 (2021); 619-631</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/2331/2129</dc:relation></oai_dc:dc>