Melola Discovery

← Melola Discovery

Journal SINTA 1

Mitigation of Lightning Hazards at the More Sensitive Points in Wind Farms Using Ant-Colony Optimization Technique

Bulletin of Electrical Engineering and Informatics · Vol. 5 No. 2 (2016) · pp. 144–159

DOI
10.11591/524
ISSN
2089-3191, 2302-9285
Published
2016-06-01
Publisher
Institute of Advanced Engineering and Science (IAES)
Language
en

Abstract

The lightning energy can be very harmfull to the wind turbine farm components. This paper attempts to evaluate the overvoltages at the sensitive points in wind farm, using ATP-EMTP package program. Four cases were performed; a) the transient voltage distribution in the insulating layer of the control line, b) the transient voltage on the control equipment, c) the coupling voltage between the tower and the control, and, d) the transient voltage distribution in the wind turbine WT generator, boast transformers and grid. These cases were performed under different lightning current conditions and at conventional design and proper design of grounding system. The results show that the ground potential rise (GPR) is reduced with using the proper design of wind turbine ground system, but the induced voltage at the control system will not affected. This work determines the optimum location of wind turbine at the areas of maximum lightning incidence. Ant colony optimization (ACO) technique is implemented to find the optimum wind farm location. This work enhances the protection strategy of the wind farms against lightning stroke.

Keywords

Collaboration network of the authors

5 authors · 7 co-authorship links

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Benha University
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Mousa A. Abd‐AllahBenha University3
A. SaidBenha University1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, first harvested 19 Nov 2026, last seen 22 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Mitigation of Lightning Hazards at the More Sensitive Points in Wind Farms Using Ant-Colony Optimization Technique</dc:title><dc:creator>MA Abd-Allah</dc:creator><dc:creator>Abdelrahman Said</dc:creator><dc:creator>Mahmoud Nour Ali</dc:creator><dc:subject>lightning protection</dc:subject><dc:subject>wind farms</dc:subject><dc:subject>wind turbines</dc:subject><dc:subject>lightning overvoltage</dc:subject><dc:subject>ground potential rise</dc:subject><dc:subject>grounding systems</dc:subject><dc:subject>wind turbine generator</dc:subject><dc:subject>lightning current</dc:subject><dc:subject>ant colony optimization</dc:subject><dc:subject>lightning incidence</dc:subject><dc:description xml:lang="en">The lightning energy can be very harmfull to the wind turbine farm components. This paper attempts to evaluate the overvoltages at the sensitive points in wind farm, using ATP-EMTP package program. Four cases were performed; a) the transient voltage distribution in the insulating layer of the control line, b) the transient voltage on the control equipment, c) the coupling voltage between the tower and the control, and, d) the transient voltage distribution in the wind turbine WT generator, boast transformers and grid. These cases were performed under different lightning current conditions and at conventional design and proper design of grounding system. The results show that the ground potential rise (GPR) is reduced with using the proper design of wind turbine ground system, but the induced voltage at the control system will not affected. This work determines the optimum location of wind turbine at the areas of maximum lightning incidence. Ant colony optimization (ACO) technique is implemented to find the optimum wind farm location. This work enhances the protection strategy of the wind farms against lightning stroke.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2016-06-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:identifier>https://doi.org/10.11591/524</dc:identifier><dc:identifier>10.11591/524</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 5 No 2 (2016); 144-159</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language></oai_dc:dc>