Melola Discovery

← Melola Discovery

Open access Journal SINTA 1

Control technique for power quality improvement of isolated wind power generation system

Bulletin of Electrical Engineering and Informatics · Vol. 12 No. 4 (2023) · pp. 1881–1892

DOI
10.11591/eei.v12i4.5082
ISSN
2089-3191, 2302-9285
Published
2023-08-01
Publisher
Institute of Advanced Engineering and Science (IAES)
Language
en
License
creativecommons.org/licenses/by-sa/4.0/

Abstract

Power quality (PQ) problems for renewable energy system (RES) is major challenge for using these systems. Amplitude, frequency, and waveform is important PQ parameters especially for standalone or isolated systems. In this paper we propose RES with wind turbine (WT) and permanent magnet synchronous generator (PMSG) to feed different loads (liner, non-liner) through AC-DC-AC converter. The PMSG operate with fuzzy logic inertia controller, to convert turbine torque form PU to Nm. The inverter stage in the converter operate according to proportional integral derivative (PID) controller with 3rd harmonic injection pulse width modulation (PWM) to regulate the AC voltage in load side. For the same case study and operating condition, we compared the result for system parameters when using ordinary PWM and using PID with 3rd harmonic injection. Voltages total harmonics distortion (THD) was less than 2% with liner loads, and 3.5% with non-liner load and the same was for current load, the voltage amplitude was between (1-1.03) PU under different wind speed by using the proposed controller.

Keywords

Collaboration network of the authors

2 authors · 1 co-authorship link · 1 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Çankırı Karatekin University
  • Middle Technical University
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, first harvested 22 Nov 2026, last seen 22 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Control technique for power quality improvement of isolated wind power generation system</dc:title><dc:creator>Göksu Görel</dc:creator><dc:creator>Inas Fadhil</dc:creator><dc:subject>power quality</dc:subject><dc:subject>permanent magnet synchronous generator</dc:subject><dc:subject>PID control</dc:subject><dc:subject>third harmonic injection</dc:subject><dc:subject>pulse width modulation</dc:subject><dc:subject>total harmonic distortion</dc:subject><dc:subject>nonlinear loads</dc:subject><dc:subject>AC-DC-AC converter</dc:subject><dc:subject>voltage regulation</dc:subject><dc:description xml:lang="en">Power quality (PQ) problems for renewable energy system (RES) is major challenge for using these systems. Amplitude, frequency, and waveform is important PQ parameters especially for standalone or isolated systems. In this paper we propose RES with wind turbine (WT) and permanent magnet synchronous generator (PMSG) to feed different loads (liner, non-liner) through AC-DC-AC converter. The PMSG operate with fuzzy logic inertia controller, to convert turbine torque form PU to Nm. The inverter stage in the converter operate according to proportional integral derivative (PID) controller with 3rd harmonic injection pulse width modulation (PWM) to regulate the AC voltage in load side. For the same case study and operating condition, we compared the result for system parameters when using ordinary PWM and using PID with 3rd harmonic injection. Voltages total harmonics distortion (THD) was less than 2% with liner loads, and 3.5% with non-liner load and the same was for current load, the voltage amplitude was between (1-1.03) PU under different wind speed by using the proposed controller.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2023-08-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:identifier>https://doi.org/10.11591/eei.v12i4.5082</dc:identifier><dc:identifier>10.11591/eei.v12i4.5082</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 12 No 4 (2023); 1881-1892</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>