Abstract

Using wind turbines (WTs) equipped with doubly fed induction generators (DFIG) is a popular technology for generating renewable energy. To ensure safe operation, prompt maintenance, and better operational reliability, the induction generator used in wind energy must be monitored. In this paper, an analysis is carried out on stator currents of the DFIG machine in a wind farm to identify any blade imbalances in the wind farm. A fault characteristics extraction analysis is carried out on the machine stator currents to detect the fault in the system. Firstly, the mathematical equation of the DFIG blade unbalanced stator current is generated using the DFIG model. Secondly, Park's Transformation is used to modify the stator's 3-phase current. Further, by evaluating the feature frequency amplitude variation in the squared signal by doing a spectral analysis on the stator current vector's squared signal. Lastly, a Simulink model for the DFIG is developed. The suggested approach analyses the fault signal of the imbalanced blade fault at various wind velocities. The outcomes show that the suggested method for diagnosing impeller imbalance faults can successfully locate the fault.

Keywords

Collaboration network of the authors

5 authors · 6 co-authorship links

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • GLA University
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Indresh YadavGLA University1
Gaurav Kumar GuptaGLA University1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, first harvested 22 Nov 2026, last seen 22 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Blade imbalance fault identification in doubly fed induction generator through current signature analysis using wavelet transform</dc:title><dc:creator>Vivek Kushwaha</dc:creator><dc:creator>Arvind Kumar Yadav</dc:creator><dc:creator>Sanjay Kumar Maurya</dc:creator><dc:subject>doubly fed induction generator</dc:subject><dc:subject>wind turbines</dc:subject><dc:subject>current signature analysis</dc:subject><dc:subject>wavelet transform</dc:subject><dc:subject>stator current</dc:subject><dc:subject>fault diagnosis</dc:subject><dc:subject>wind farm monitoring</dc:subject><dc:subject>Park's transformation</dc:subject><dc:subject>spectral analysis</dc:subject><dc:subject>wind speed</dc:subject><dc:description xml:lang="en">Using wind turbines (WTs) equipped with doubly fed induction generators (DFIG) is a popular technology for generating renewable energy. To ensure safe operation, prompt maintenance, and better operational reliability, the induction generator used in wind energy must be monitored. In this paper, an analysis is carried out on stator currents of the DFIG machine in a wind farm to identify any blade imbalances in the wind farm. A fault characteristics extraction analysis is carried out on the machine stator currents to detect the fault in the system. Firstly, the mathematical equation of the DFIG blade unbalanced stator current is generated using the DFIG model. Secondly, Park's Transformation is used to modify the stator's 3-phase current. Further, by evaluating the feature frequency amplitude variation in the squared signal by doing a spectral analysis on the stator current vector's squared signal. Lastly, a Simulink model for the DFIG is developed. The suggested approach analyses the fault signal of the imbalanced blade fault at various wind velocities. The outcomes show that the suggested method for diagnosing impeller imbalance faults can successfully locate the fault.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2024-06-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v13i3.5679</dc:identifier><dc:identifier>10.11591/eei.v13i3.5679</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 13 No 3 (2024); 2131-2141</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/5679/3750</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>