Abstract

Machine condition monitoring in remote locations and harsh environment where network infrastructure is not feasible, or hardwired network connectivity is not possible, wireless communications provides an alternative which also offer installation cost savings, improve reliability and quicker deployment. This paper describes the implementation of wireless sensor network (WSN) for early fault diagnosis of rolling element bearings based on signal autocorrelation technique. A low-power 2.4 GHz wireless HART transceiver, a low-cost wireless vibration transmitter, 26.76 mv/g accelerometers and a 1420 wireless gateway with AMS software was implemented. The research describes the methodology of acquiring peak values data in high frequency region. The noise was averaged out by applying four-time averaging and natural frequencies or fault frequencies of bearing elements was captured. The experimental results show that the signal autocorrelation algorithm can successfully diagnose the roller bearing faults at early stage on wireless signal transfer. As the raw data was processed before wireless transmission on analyzing unit and spectrum was transferred in JPG format on display unit, minimum power consumption has been noted. The technique provided a better alternative of wired system for real time condition monitoring of roller bearings in rotating equipment installed in remote area.

Keywords

Collaboration network of the authors

2 authors · 1 co-authorship link

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, first harvested 22 Nov 2026, last seen 22 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Early faults diagnosis and severity assessment of rolling element bearings on wireless signal transfer</dc:title><dc:creator>Ghulam Mustafa</dc:creator><dc:creator>Shahab Khushnood</dc:creator><dc:subject>rolling bearings</dc:subject><dc:subject>early fault diagnosis</dc:subject><dc:subject>fault severity estimation</dc:subject><dc:subject>wireless sensor networks</dc:subject><dc:subject>signal autocorrelation</dc:subject><dc:subject>vibration analysis</dc:subject><dc:subject>remote condition monitoring</dc:subject><dc:subject>low-power wireless communication</dc:subject><dc:subject>rotating machinery</dc:subject><dc:description xml:lang="en">Machine condition monitoring in remote locations and harsh environment where network infrastructure is not feasible, or hardwired network connectivity is not possible, wireless communications provides an alternative which also offer installation cost savings, improve reliability and quicker deployment. This paper describes the implementation of wireless sensor network (WSN) for early fault diagnosis of rolling element bearings based on signal autocorrelation technique. A low-power 2.4 GHz wireless HART transceiver, a low-cost wireless vibration transmitter, 26.76 mv/g accelerometers and a 1420 wireless gateway with AMS software was implemented. The research describes the methodology of acquiring peak values data in high frequency region. The noise was averaged out by applying four-time averaging and natural frequencies or fault frequencies of bearing elements was captured. The experimental results show that the signal autocorrelation algorithm can successfully diagnose the roller bearing faults at early stage on wireless signal transfer. As the raw data was processed before wireless transmission on analyzing unit and spectrum was transferred in JPG format on display unit, minimum power consumption has been noted. The technique provided a better alternative of wired system for real time condition monitoring of roller bearings in rotating equipment installed in remote area.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2022-02-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v11i1.3548</dc:identifier><dc:identifier>10.11591/eei.v11i1.3548</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 11 No 1 (2022); 221-230</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/3548/2492</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>