Melola Discovery

← Melola Discovery

Open access Journal SINTA 1

Design of passive voltage balancer system for lead acid battery

Bulletin of Electrical Engineering and Informatics · Vol. 13 No. 2 (2024) · pp. 724–733

DOI
10.11591/eei.v13i2.5806
ISSN
2089-3191, 2302-9285
Published
2024-04-01
Publisher
Institute of Advanced Engineering and Science (IAES)
Language
en
License
creativecommons.org/licenses/by-sa/4.0/

Abstract

The use of rechargeable batteries for electrical energy storage requires a voltage balancing system. The voltage balancing system requires monitoring in the use of rechargeable batteries so that they can be utilized properly and can improve the electrical energy storage system. In this research, a monitored lead acid battery voltage balancing system was designed so that the management of the battery voltage balance level and the storage of electrical energy in rechargeable batteries can be stored and used optimally. In this research a series of lead acid battery voltage detection and power dissipation circuits were designed. The power dissipation circuit uses the controlled shunt resistor method which is used when the voltage of the lead acid battery being charged exceeds the maximum voltage. This method is easy to implement and can display the value of the lead acid battery voltage and other parameters, so that it can be monitored by the user. The results obtained show that the average voltage error for batteries 1 and 2 is 0.09% and 0.3% respectively. The power dissipation circuit can dissipate lead acid battery power above the reference voltage VREF=±7 V, with a balanced voltage of 6.8 V at 140 minutes and 160 minutes.

Keywords

Collaboration network of the authors

12 authors · 19 co-authorship links · 7 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Telkom University
  • Universitas Airlangga
  • Politeknik Negeri Bandung
  • Institut Teknologi Sepuluh Nopember
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Dien RahmawatiTelkom University1
Achmad RizalTelkom University1
Prisma MegantoroUniversitas Airlangga1
Brahmantya Aji PramuditaTelkom University1
Kevin Octavianov AbdurohmanTelkom University1
Adi SoeprijantoInstitut Teknologi Sepuluh Nopember1
Jangkung RaharjoTelkom University1
Hermagasantos ZeinPoliteknik Negeri Bandung1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, first harvested 22 Nov 2026, last seen 22 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Design of passive voltage balancer system for lead acid battery</dc:title><dc:creator>Bandiyah Sri Aprillia</dc:creator><dc:creator>Desri Kristina Silalahi</dc:creator><dc:creator>Kharisma Bani Adam</dc:creator><dc:creator>Putu Krishna Bhaskara Perteka Yuda</dc:creator><dc:subject>lead-acid batteries</dc:subject><dc:subject>voltage balancing</dc:subject><dc:subject>battery monitoring</dc:subject><dc:subject>shunt resistor</dc:subject><dc:subject>rechargeable batteries</dc:subject><dc:subject>electrical energy storage</dc:subject><dc:description xml:lang="en">The use of rechargeable batteries for electrical energy storage requires a voltage balancing system. The voltage balancing system requires monitoring in the use of rechargeable batteries so that they can be utilized properly and can improve the electrical energy storage system. In this research, a monitored lead acid battery voltage balancing system was designed so that the management of the battery voltage balance level and the storage of electrical energy in rechargeable batteries can be stored and used optimally. In this research a series of lead acid battery voltage detection and power dissipation circuits were designed. The power dissipation circuit uses the controlled shunt resistor method which is used when the voltage of the lead acid battery being charged exceeds the maximum voltage. This method is easy to implement and can display the value of the lead acid battery voltage and other parameters, so that it can be monitored by the user. The results obtained show that the average voltage error for batteries 1 and 2 is 0.09% and 0.3% respectively. The power dissipation circuit can dissipate lead acid battery power above the reference voltage VREF=±7 V, with a balanced voltage of 6.8 V at 140 minutes and 160 minutes.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2024-04-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v13i2.5806</dc:identifier><dc:identifier>10.11591/eei.v13i2.5806</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 13 No 2 (2024); 724-733</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://doi.org/10.11591/eei.v13i2.5806</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>