Melola Discovery

← Melola Discovery

Journal SINTA 1

Optimal distributed generation in green building assessment towards line loss reduction for Malaysian public hospital

Bulletin of Electrical Engineering and Informatics · Vol. 8 No. 4 (2019)

DOI
10.11591/eei.v8i4.1624
ISSN
2089-3191, 2302-9285
Published
2019-12-01
Publisher
Institute of Advanced Engineering and Science (IAES)
Language
en

Abstract

This paper presents an optimization approach for criteria setting of Renewable Distributed Generation (DG) in the Green Building Rating System (GBRS). In this study, the total line loss reduction is analyzed and set as the main objective function in the optimization process which then a reassessment of existing criteria setting for renewable energy (RE) is proposed towards lower loss outcome. Solar photovoltaic (PV)-type DG unit (PV-DG) is identified as the type of DG used in this paper. The proposed PV-DG optimization will improve the sustainable energy performance of the green building by total line losses reduction within accepted lower losses region using Artificial bee colony (ABC) algorithm. The distribution network uses bus and line data setup from selected one of each three levels of Malaysian public hospital. MATLAB simulation result shows that the PV-DG expanding capacity towards optimal scale and location provides a better outcome in minimizing total line losses within an appropriate voltage profile as compared to the current setting of PV-DG imposed in selected GBRS. Thus, reassessment of RE parameter setting and the proposed five rankings with new PV-DG setting for public hospital provides technical justification and give the best option to the green building developer for more effective RE integration.

Keywords

Collaboration network of the authors

39 authors · 236 co-authorship links · 156 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • University of Technology Malaysia
  • Robert Gordon University
  • University of Kuala Lumpur
  • Jubail Industrial College
  • Glasgow Caledonian University
  • Ministry of Health
  • Universidad Técnica Federico Santa María
  • Other organisations
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Abdullahi Abubakar Mas’udJubail Industrial College23
Siti Hawa Abu-BakarUniversity of Kuala Lumpur15
Jorge Alfredo Ardila ReyUniversidad Técnica Federico Santa María12
Nazmi SellamiRobert Gordon University8
Jasrul Jamani JamianUniversity of Technology Malaysia6
Z Abdul-MalekUniversity of Technology Malaysia6
Kamilia KamardinUniversity of Technology Malaysia6
Hamza AhmadTun Hussein Onn University of Malaysia6
Abu Bakar MunirUniversity of Malaya6
Zulkurnain Abdul‐MalekUniversity of Technology Malaysia4
Siti Armiza Mohd ArisUniversity of Technology Malaysia4
Siti Zura A. JalilUniversity of Technology Malaysia4
Sharipah Alwiah Syed Abd RahamanUniversity of Technology Malaysia4
Christopher Julian MahandranUniversity of Technology Malaysia4
Abdul Yasser Abd FatahUniversity of Technology Malaysia4
Daria FreierGlasgow Caledonian University3
Roberto Ramírez-ÍñiguezGlasgow Caledonian University3
Tapas Kumar MallickUniversity of Exeter3
Siti Hajar Mohd YasinUniversiti Teknologi MARA3
Siti Sarah Abu-BakarKing's College London3
Mohd Alif Saifuddin JamalludinAffiliation unknown3
Fadzliana RamleeUniversity of Glasgow3
Ahmad Syahrir AyubUniversity of Kuala Lumpur3
Mantas DarameičikasRobert Gordon University3
Ahmad Syahir AyubAffiliation unknown2
Jonas TaverneRobert Gordon University2
Draco IyiRobert Gordon University2
Ibrahim Abubakar Mas’udAffiliation unknown2
Ridoan KarimMonash University Malaysia2
Mu’azu Mohammed AbdullahiUniversity of Hafr Al-Batin2
Ahmad Shakir Mohd SaudiUniversity of Kuala Lumpur2
Asan Vernyuy WirbaJubail Industrial College2

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, first harvested 19 Nov 2026, last seen 22 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Optimal distributed generation in green building assessment towards line loss reduction for Malaysian public hospital</dc:title><dc:creator>Mohd Effendi Amran</dc:creator><dc:creator>Mohd Nabil Muhtazaruddin</dc:creator><dc:creator>Nurul Aini Bani</dc:creator><dc:creator>Hazilah Mad Kaidi</dc:creator><dc:creator>Mohamad Zaki Hassan</dc:creator><dc:creator>Shamsul Sarip</dc:creator><dc:creator>Firdaus Muhammad‐Sukki</dc:creator><dc:subject>distributed generation</dc:subject><dc:subject>green building certification</dc:subject><dc:subject>line loss reduction</dc:subject><dc:subject>photovoltaics</dc:subject><dc:subject>artificial bee colony algorithm</dc:subject><dc:subject>public hospitals</dc:subject><dc:subject>voltage profile</dc:subject><dc:subject>distribution networks</dc:subject><dc:subject>Malaysian public hospitals</dc:subject><dc:description xml:lang="en">This paper presents an optimization approach for criteria setting of Renewable Distributed Generation (DG) in the Green Building Rating System (GBRS). In this study, the total line loss reduction is analyzed and set as the main objective function in the optimization process which then a reassessment of existing criteria setting for renewable energy (RE) is proposed towards lower loss outcome. Solar photovoltaic (PV)-type DG unit (PV-DG) is identified as the type of DG used in this paper. The proposed PV-DG optimization will improve the sustainable energy performance of the green building by total line losses reduction within accepted lower losses region using Artificial bee colony (ABC) algorithm. The distribution network uses bus and line data setup from selected one of each three levels of Malaysian public hospital. MATLAB simulation result shows that the PV-DG expanding capacity towards optimal scale and location provides a better outcome in minimizing total line losses within an appropriate voltage profile as compared to the current setting of PV-DG imposed in selected GBRS. Thus, reassessment of RE parameter setting and the proposed five rankings with new PV-DG setting for public hospital provides technical justification and give the best option to the green building developer for more effective RE integration.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2019-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v8i4.1624</dc:identifier><dc:identifier>10.11591/eei.v8i4.1624</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 8 No 4 (2019)</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/1624/1192</dc:relation></oai_dc:dc>