Abstract

Gapless surge arresters (GLSA) constructed with zinc oxide (ZnO) element is connected in electrical power system for protection against surge voltage. For condition monitoring of GLSA conventionally offline and online techniques are available. However, offline techniques are not much useful as it requires system shutdown and hence online techniques are more useful. Online surge arrester monitoring technique based on leakage current analysis is adopted by all stakeholders. However, in this method supply system harmonics plays major roles in measurement accuracy to determine health index. In this paper improved health monitoring indexes for GLSA diagnostic based on ratios of leakage current components has been proposed. The ageing process has been done with application of lightning Impulse current, surface contamination due to salt fog, temperature effect, and moisture ingress. Various experimental tests have been carried out on porcelain and polymer housed surge arresters to evaluate the ability of proposed method. Obtained results of 9 kV, 18 kV, and 30 kV healthy and degraded metal oxide GLSAs have been shown the viability of improved health indexes on surge arrester condition monitoring procedures. The experimental investigation and discussion of the obtained results reflects sufficient and effective trails to utility engineers to determine health of surge arresters and able to effectively schedule further maintenance plan.

Keywords

Collaboration network of the authors

2 authors · 1 co-authorship link · 1 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Charotar University of Science and Technology
  • Parul University
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, first harvested 19 Nov 2026, last seen 22 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Advance technique for online condition monitoring of surge arresters</dc:title><dc:creator>Anil S. Khopkar</dc:creator><dc:creator>Kartik S. Pandya</dc:creator><dc:subject>zinc oxide surge arrester</dc:subject><dc:subject>online condition monitoring</dc:subject><dc:subject>health indicators</dc:subject><dc:subject>moisture ingress</dc:subject><dc:subject>maintenance scheduling</dc:subject><dc:description xml:lang="en">Gapless surge arresters (GLSA) constructed with zinc oxide (ZnO) element is connected in electrical power system for protection against surge voltage. For condition monitoring of GLSA conventionally offline and online techniques are available. However, offline techniques are not much useful as it requires system shutdown and hence online techniques are more useful. Online surge arrester monitoring technique based on leakage current analysis is adopted by all stakeholders. However, in this method supply system harmonics plays major roles in measurement accuracy to determine health index. In this paper improved health monitoring indexes for GLSA diagnostic based on ratios of leakage current components has been proposed. The ageing process has been done with application of lightning Impulse current, surface contamination due to salt fog, temperature effect, and moisture ingress. Various experimental tests have been carried out on porcelain and polymer housed surge arresters to evaluate the ability of proposed method. Obtained results of 9 kV, 18 kV, and 30 kV healthy and degraded metal oxide GLSAs have been shown the viability of improved health indexes on surge arrester condition monitoring procedures. The experimental investigation and discussion of the obtained results reflects sufficient and effective trails to utility engineers to determine health of surge arresters and able to effectively schedule further maintenance plan.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2025-08-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v14i4.9457</dc:identifier><dc:identifier>10.11591/eei.v14i4.9457</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 14 No 4 (2025); 2526-2536</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/9457/4267</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>