Open access
Journal
SINTA 1
Improving COVID-19 chest X-ray classification via attention-based learning and fuzzy-augmented data diversity
Bulletin of Electrical Engineering and Informatics · Vol. 14 No. 5 (2025) · pp. 4025–4035
ISSN 2089-3191, 2302-9285
Published 2025-10-01
Publisher Institute of Advanced Engineering and Science (IAES)
Language en
Abstract
This paper presents a hybrid deep learning (DL) framework that combines model-level and data-level enhancements to improve classification performance without compromising clinical relevance. The proposed framework consisted of an EfficientNetB0 model with a hybrid attention module, which focused attention both spatially and channel-wise, and a VGG-16 model that was trained on training data augmented using a fuzzy-logic-based contrast and brightness enhancement. The attention module focused the model by recalibrating the features in an adaptive manner. The fuzzy-logic augmentation increased data diversity while maintaining the anatomical fidelity of the medical image domain. In addition, an uncertainty-aware ensemble approach was utilized to combine both models' predictions, which considered model confidence and entropy of the predictions, to enhance the reliability of the predictions. The proposed framework achieves a classification accuracy of 99.6%, outperforming several existing approaches.
Collaboration network of the authors
3 authors ·
2 co-authorship links
Hover or tap a name to highlight its co-authors. Double-click to open the author's page.
B.M.S. College of Engineering Affiliation unknown
Different organisations
Same organisation
Affiliation unknown
Thicker line = more joint articles · bigger circle = more articles
Show as table
Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.
Metadata source: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, first harvested 19 Nov 2026, last seen 22 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Improving COVID-19 chest X-ray classification via attention-based learning and fuzzy-augmented data diversity</dc:title><dc:creator>Girish Shyadanahalli Cheluvaraju</dc:creator><dc:creator>B S Jayasri</dc:creator><dc:subject>COVID-19 pandemic</dc:subject><dc:subject>chest X-ray classification</dc:subject><dc:subject>attention mechanism</dc:subject><dc:subject>channel attention</dc:subject><dc:subject>image enhancement</dc:subject><dc:subject>data augmentation</dc:subject><dc:subject>EfficientNetB0</dc:subject><dc:subject>VGG16</dc:subject><dc:subject>ensemble learning</dc:subject><dc:subject>prediction confidence</dc:subject><dc:subject>entropy-based uncertainty</dc:subject><dc:description xml:lang="en">This paper presents a hybrid deep learning (DL) framework that combines model-level and data-level enhancements to improve classification performance without compromising clinical relevance. The proposed framework consisted of an EfficientNetB0 model with a hybrid attention module, which focused attention both spatially and channel-wise, and a VGG-16 model that was trained on training data augmented using a fuzzy-logic-based contrast and brightness enhancement. The attention module focused the model by recalibrating the features in an adaptive manner. The fuzzy-logic augmentation increased data diversity while maintaining the anatomical fidelity of the medical image domain. In addition, an uncertainty-aware ensemble approach was utilized to combine both models' predictions, which considered model confidence and entropy of the predictions, to enhance the reliability of the predictions. The proposed framework achieves a classification accuracy of 99.6%, outperforming several existing approaches.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2025-10-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v14i5.10861</dc:identifier><dc:identifier>10.11591/eei.v14i5.10861</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 14 No 5 (2025); 4025-4035</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/10861/4419</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>
Citations and indexing
OpenAlex
Indexed
via ID karya OpenAlex (record dari sumber OpenAlex)
1 citation
Crossref
Indexed
via DOI
0 citations
Counts as reported by each index on 19 Nov 2026; indexes count citations differently.
OpenAlex also lists this work in: crossref.
Cite this article
APA 7
Cheluvaraju, G. S., & Jayasri, B. S. (2025). Improving COVID-19 chest X-ray classification via attention-based learning and fuzzy-augmented data diversity. Bulletin of Electrical Engineering and Informatics, 14(5), 4025–4035. https://doi.org/10.11591/eei.v14i5.10861
Copy
IEEE
G. S. Cheluvaraju and B. S. Jayasri, “Improving COVID-19 chest X-ray classification via attention-based learning and fuzzy-augmented data diversity,” Bulletin of Electrical Engineering and Informatics, vol. 14, no. 5, pp. 4025–4035, 2025, doi: 10.11591/eei.v14i5.10861.
Copy
Generated from the journal's metadata; check author names before use.