Melola Discovery

← Melola Discovery

Open access Journal SINTA 1

Texture features analysis technique to detect mass lesion in digitized mammogram images

Bulletin of Electrical Engineering and Informatics · Vol. 12 No. 5 (2023) · pp. 2923–2929

DOI
10.11591/eei.v12i5.4701
ISSN
2089-3191, 2302-9285
Published
2023-10-01
Publisher
Institute of Advanced Engineering and Science (IAES)
Language
en
License
creativecommons.org/licenses/by-sa/4.0/

Abstract

Mass lesions are one of the breast cancer tumors. Mammogram images are the first screening tool to detect tumors in the women breast, but due to radiologist fatigue, number of false positive (FP) and false negative (FN) rates are increased. The main objective of this paper is to develop an intelligent computer aided diagnosis (CAD) system that can accurately detect mass lesions in digitized mammogram images. The proposed method has three stages. The first stage is a preprocessing stage, where the mass lesion is enhanced using a customized Laplacian filter. Then, multi-statistical filters are implemented to detect a potential mass lesion in the mammogram images. In the final stage, the number detected FP regions are reduced using five texture features. The proposed algorithm is evaluated using 45 mammogram images and the algorithm achieved an accuracy rate of 97% in detecting mass lesion with 83% sensitivity rate and 98% specificity rate.

Keywords

Collaboration network of the authors

12 authors · 23 co-authorship links · 14 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Applied Science Private University
  • Ohio Northern University
  • Al Ain University
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Ali M. BaniyounesApplied Science Private University5
Ayman A Abu BakerAffiliation unknown2
Nader SantarisiApplied Science Private University2
Ayman Abu BakerAffiliation unknown1
Eyad RadwanApplied Science Private University1
Khalid Al-OlimatOhio Northern University1
Maryam Mahmoud Akho-ZahiehApplied Science Private University1
Eyad AdwanApplied Science Private University1
Kalid OliematOhio Northern University1
Mazen AlnabulsiApplied Science Private University1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, first harvested 22 Nov 2026, last seen 22 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Texture features analysis technique to detect mass lesion in digitized mammogram images</dc:title><dc:creator>Ayman AbuBaker</dc:creator><dc:creator>Yazeed Yasin Ghadi</dc:creator><dc:subject>breast cancer</dc:subject><dc:subject>mammography</dc:subject><dc:subject>computer-aided diagnosis</dc:subject><dc:subject>texture features</dc:subject><dc:subject>Laplacian filter</dc:subject><dc:subject>false positive reduction</dc:subject><dc:description xml:lang="en">Mass lesions are one of the breast cancer tumors. Mammogram images are the first screening tool to detect tumors in the women breast, but due to radiologist fatigue, number of false positive (FP) and false negative (FN) rates are increased. The main objective of this paper is to develop an intelligent computer aided diagnosis (CAD) system that can accurately detect mass lesions in digitized mammogram images. The proposed method has three stages. The first stage is a preprocessing stage, where the mass lesion is enhanced using a customized Laplacian filter. Then, multi-statistical filters are implemented to detect a potential mass lesion in the mammogram images. In the final stage, the number detected FP regions are reduced using five texture features. The proposed algorithm is evaluated using 45 mammogram images and the algorithm achieved an accuracy rate of 97% in detecting mass lesion with 83% sensitivity rate and 98% specificity rate.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2023-10-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>http://dx.doi.org/10.11591/eei.v12i5.4701</dc:identifier><dc:identifier>10.11591/eei.v12i5.4701</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 12 No 5 (2023); 2923-2929</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/4701/3404</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>