Melola Discovery

← Melola Discovery

Open access Journal SINTA 1

Development of Voltammetry Analysis Method of Copper Metal Ions by Solid-State Membrane with Carbon Nanotube

Indonesian Journal of Chemistry · Vol. 21 No. 2 (2021) · pp. 332–332

DOI
10.22146/ijc.55056
ISSN
1411-9420, 2460-1578
Published
2021-03-23
Publisher
Gadjah Mada University
Language
en
License
creativecommons.org/licenses/by-nc-nd/4.0/

Abstract

This study was aimed to develop a method for metal analysis in continuous integration using voltammetry techniques. The research subject was copper(II) ions. The objects of research were linearity, scan rate, repeatability of readings, and the presence of Cu(II) levels in well water samples. In this study, a selective electrode was developed with a solid membrane voltammetry system using differential pulse voltammetry measurement. The results showed the regression line of voltammetry method, y = 10.265 ln (x) + 330.47, with a correlation value of 0.9654, the optimum scan rate was 10 mV/s, and within five repetitions of each measurement for one electrode, it showed good repeatability. Meanwhile, the result of regression with the UV-Vis spectrophotometric method for Cu(II) was y = 0.12386x + 0.00879 with a correlation value of 0.9943. The voltammetry method was found to be much better than the UV-Vis method because it was able to be used for analysis up to a concentration of 6.35 × 10–4 ppm (or 1.00 × 10–11 M), while the UV-Vis method was only able to analyze up to 1.5 ppm (or 2.36 × 10–5 M).

Keywords

Collaboration network of the authors

40 authors · 136 co-authorship links · 57 across different organisations · showing the 40 most connected

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Universitas Gadjah Mada
  • Yogyakarta State University
  • Sultan Idris Education University
  • Universitas Negeri Padang
  • Institut Teknologi Sepuluh Nopember
  • Institut Agama Islam Darul Ulum Kandangan
  • Universitas Jambi
  • Other organisations
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Nuryono NuryonoUniversitas Gadjah Mada6
Noorshida Mohd AliSultan Idris Education University4
Norhayati HashimSultan Idris Education University4
Norlaili Abu BakarSultan Idris Education University4
Sharifah Norain Mohd SharifSultan Idris Education University4
Maizatul Najwa JajuliSultan Idris Education University4
Endang Tri WahyuniUniversitas Gadjah Mada3
Agus KuncakaUniversitas Gadjah Mada3
Mudasir MudasirUniversitas Gadjah Mada3
Suherman SuhermanUniversitas Gadjah Mada2
Linda Johana LatumahinaUniversitas Gadjah Mada2
Triyono TriyonoUniversitas Gadjah Mada2
Narsito NarsitoUniversitas Gadjah Mada2
Eko Sri KunartiUniversitas Gadjah Mada2
Sutarno SutarnoUniversitas Gadjah Mada2
Sri Juari SantosaUniversitas Gadjah Mada2
İnsih WilujengYogyakarta State University1
Muhammad RasyidInstitut Agama Islam Darul Ulum Kandangan1
Habibatul UnayahYogyakarta State University1
Laifa RahmawatiYogyakarta State University1
Tiara NurcihikitaAffiliation unknown1
Rosa LiyaAffiliation unknown1
Yustina Novi KurniatiYogyakarta State University1
Haryadi HaryadiUniversitas Jambi1
Sugiyarto SugiyartoPoliteknik Kesehatan Kemenkes Surakarta1
Muji SetiyoUniversitas Muhammadiyah Magelang1
Bambang SudarmantaInstitut Teknologi Sepuluh Nopember1
Randi Purnama PutraUniversitas Negeri Padang1
Dori YuvendaUniversitas Negeri Padang1
Jamaludin JamaludinInstitut Teknologi Sepuluh Nopember1
Oki MurazaPertamina (Indonesia)1
Remon LapisaUniversitas Negeri Padang1
Krismadinata KrismadinataUniversitas Negeri Padang1
Asnil AsnilUniversitas Negeri Padang1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2764840418, first harvested 19 Nov 2026, last seen 22 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Development of Voltammetry Analysis Method of Copper Metal Ions by Solid-State Membrane with Carbon Nanotube</dc:title><dc:creator>Suyanta Suyanta</dc:creator><dc:creator>Sunarto Sunarto</dc:creator><dc:creator>Regina Tutik Padmaningrum</dc:creator><dc:creator>Karlinda Karlinda</dc:creator><dc:creator>Illyas Md Isa</dc:creator><dc:creator>Rahadian Zainul</dc:creator><dc:subject>copper(II) determination</dc:subject><dc:subject>carbon nanotubes</dc:subject><dc:subject>differential pulse voltammetry</dc:subject><dc:subject>selective electrode</dc:subject><dc:subject>well water analysis</dc:subject><dc:subject>heavy metal contamination</dc:subject><dc:subject>detection limit</dc:subject><dc:description xml:lang="en">This study was aimed to develop a method for metal analysis in continuous integration using voltammetry techniques. The research subject was copper(II) ions. The objects of research were linearity, scan rate, repeatability of readings, and the presence of Cu(II) levels in well water samples. In this study, a selective electrode was developed with a solid membrane voltammetry system using differential pulse voltammetry measurement. The results showed the regression line of voltammetry method, y = 10.265 ln (x) + 330.47, with a correlation value of 0.9654, the optimum scan rate was 10 mV/s, and within five repetitions of each measurement for one electrode, it showed good repeatability. Meanwhile, the result of regression with the UV-Vis spectrophotometric method for Cu(II) was y = 0.12386x + 0.00879 with a correlation value of 0.9943. The voltammetry method was found to be much better than the UV-Vis method because it was able to be used for analysis up to a concentration of 6.35 × 10–4 ppm (or 1.00 × 10–11 M), while the UV-Vis method was only able to analyze up to 1.5 ppm (or 2.36 × 10–5 M).</dc:description><dc:publisher>Gadjah Mada University</dc:publisher><dc:date>2021-03-23</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.22146/ijc.55056</dc:identifier><dc:identifier>10.22146/ijc.55056</dc:identifier><dc:source>Indonesian Journal of Chemistry; Vol 21 No 2 (2021); 332-332</dc:source><dc:source>1411-9420</dc:source><dc:source>2460-1578</dc:source><dc:language>en</dc:language><dc:relation>https://jurnal.ugm.ac.id/ijc/article/download/55056/30090</dc:relation><dc:rights>https://creativecommons.org/licenses/by-nc-nd/4.0/</dc:rights></oai_dc:dc>