Abstract

Determination of limit detection of the elements N, P, K, Si, Al, Fe, Cu, Cd, with fast neutron activation using neutron generator has been done. Samples prepared from SRM 2704, N, P, K elements from MERCK, Cu, Cd, Al from activation foil made in San Carlos, weighted and packed for certain weight then iradiated during 30 minutes with 14 MeV fast neutron using the neutron generator and then counted with gamma spectrometry (accuspec). At this research condition of neutron generator was set at current 1 mA that produced neutron flux about 5,47.107 n/cm2.s and experimental result shown that the limit detection for the elements N, P, K, Si, Al, Fe, Cu, Cd are 2,44 ppm, 1,88 ppm, 2,15 ppm, 1,44 ppm, 1,26 ppm, 1,35 ppm, 1,05 ppm, 2,99 ppm, respectively. The data indicate that the limit detection or sensitivity of appliance of neutron generator to analyze the element is very good, which is feasible to get accreditation AANC laboratory using neutron generator. Keywords: limit detection, AANC, neutron generator

Keywords

Collaboration network of the authors

27 authors · 83 co-authorship links · 38 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • National Research and Innovation Agency
  • Universitas Gadjah Mada
  • Politeknik Penerbangan Palembang
  • National Nuclear Energy Agency of Indonesia
  • Lambung Mangkurat University
  • University of Indonesia
  • University of Nusa Cendana
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Sutarno SutarnoUniversitas Gadjah Mada2
Yateman ArryantoUniversitas Gadjah Mada2
C. SupriyantoNational Nuclear Energy Agency of Indonesia2
Widajanti WibowoUniversity of Indonesia1
Indra YuliaUniversity of Indonesia1
Yiyi SulaemanNational Research and Innovation Agency1
Sri Nuryani Hidayah UtamiUniversitas Gadjah Mada1
Puspita Harum MaharaniNational Research and Innovation Agency1
Eni Maftu’ahNational Research and Innovation Agency1
Khairatun NapisahNational Research and Innovation Agency1
Mukhlis MukhlisNational Research and Innovation Agency1
Rina Dirgahayu NingsihNational Research and Innovation Agency1
Anna HairaniNational Research and Innovation Agency1
Siswadi SiswadiNational Research and Innovation Agency1
Direstu AmaliaPoliteknik Penerbangan Palembang1
Rio RizkoPoliteknik Penerbangan Palembang1
Wildan NugrahaPoliteknik Penerbangan Palembang1
Jhellyananda PutriPoliteknik Penerbangan Palembang1
Randa Agusta PratamaPoliteknik Penerbangan Palembang1
Mustofa MustofaUniversitas Gadjah Mada1
Jumina JuminaUniversitas Gadjah Mada1
Chairil AnwarUniversitas Gadjah Mada1
I Gusti Made Ngurah BudianaUniversity of Nusa Cendana1
Utami IrawatiLambung Mangkurat University1
Samin SaminNational Nuclear Energy Agency of Indonesia1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2764840418, first harvested 19 Nov 2026, last seen 19 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">DETERMINATION OF LIMIT DETECTION OF THE ELEMENTS N, P, K, Si, Al, Fe, Cu, Cd, WITH FAST NEUTRON ACTIVATION USING NEUTRON GENERATOR</dc:title><dc:creator>Sunardi Sunardi</dc:creator><dc:creator>Muryono Muryono</dc:creator><dc:subject>detection limit</dc:subject><dc:subject>fast neutron activation analysis</dc:subject><dc:subject>neutron generator</dc:subject><dc:subject>trace element analysis</dc:subject><dc:subject>nitrogen</dc:subject><dc:subject>phosphorus</dc:subject><dc:subject>potassium</dc:subject><dc:subject>silicon</dc:subject><dc:subject>aluminum</dc:subject><dc:subject>iron</dc:subject><dc:subject>copper</dc:subject><dc:subject>cadmium</dc:subject><dc:subject>neutron flux</dc:subject><dc:subject>gamma-ray spectroscopy</dc:subject><dc:description xml:lang="en">Determination of limit detection of the elements N, P, K, Si, Al, Fe, Cu, Cd, with fast neutron activation using neutron generator has been done. Samples prepared from SRM 2704, N, P, K elements from MERCK, Cu, Cd, Al from activation foil made in San Carlos, weighted and packed for certain weight then iradiated during 30 minutes with 14 MeV fast neutron using the neutron generator and then counted with gamma spectrometry (accuspec). At this research condition of neutron generator was set at current 1 mA that produced neutron flux about 5,47.107 n/cm2.s and experimental result shown that the limit detection for the elements N, P, K, Si, Al, Fe, Cu, Cd are 2,44 ppm, 1,88 ppm, 2,15 ppm, 1,44 ppm, 1,26 ppm, 1,35 ppm, 1,05 ppm, 2,99 ppm, respectively. The data indicate that the limit detection or sensitivity of appliance of neutron generator to analyze the element is very good, which is feasible to get accreditation AANC laboratory using neutron generator. Keywords: limit detection, AANC, neutron generator</dc:description><dc:publisher>Gadjah Mada University</dc:publisher><dc:date>2010-06-14</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:identifier>https://doi.org/10.22146/ijc.21755</dc:identifier><dc:identifier>10.22146/ijc.21755</dc:identifier><dc:source>Indonesian Journal of Chemistry; Vol 6 No 2 (2010); 170-174</dc:source><dc:source>1411-9420</dc:source><dc:source>2460-1578</dc:source><dc:language>en</dc:language><dc:rights>https://creativecommons.org/licenses/by-nc-nd/4.0/</dc:rights></oai_dc:dc>