FIELD EXPERIMENTATION ON WALL SURFACE TEMPERATURE WITH FABA BRICK IN HOT CONDITIONS

Logic: Jurnal Rancang Bangun dan Teknologi · Vol. 22 No. 2 (2022) · pp. 190–200

DOI
10.31940/logic.v22i2.198-208
ISSN
2580-5649, 1412-114X
Published
2022-07-30
Publisher
Unit Publikasi Ilmiah, P3M, Politeknik Negeri Bali
Language
eng

Abstract

The processing of coal waste into building materials from fly ash bottom ash has been stipulated in Regulation number 22 of 2021 as Non-Hazardous material, with a note that the management requirements must still meet the standards and technical requirements set out and listed in the environmental document approval. Previous studiesstated that one of the physical characteristics of the use of this waste (fly ash bottom ash) can be in improving the quality of construction materials and environmental quality. The research questions of this study are: Does the facing east orientation quantitatively receiving more heat of the morning sun than other orientations? Does FABA brick walls affect the indoor thermal performance? The wall surface temperature measurement is carried out by the field experimentation with extreme climatic conditions, both sunny and rainy weather in 2021. The results of this study found that the surface temperature profile of the brick wall oriented to the east in sunny rainy/cold weather is cooler 2 % compared to the temperature on the western side. The wall surface temperature profile in the morning is 25% warmer than the ambient air temperature in sunny weather and 9% cooler in rainy weather. wall material with FABA brick proves that the orientation, location and character of the microclimate are significant to the thermal value.

Keywords

Collaboration network of the authors

6 authors · 9 co-authorship links

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Diponegoro University
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Hepi Duchovny YoungDiponegoro University2
Erni SetyowatiDiponegoro University2
Maria Rosita MaharaniDiponegoro University1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OAI-PMH (metadata jurnal) https://ojs2.pnb.ac.id/index.php/LOGIC/oai, first harvested 19 Nov 2026, last seen 19 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">FIELD EXPERIMENTATION ON WALL SURFACE TEMPERATURE WITH FABA BRICK IN HOT CONDITIONS</dc:title>
	<dc:creator>Vira Ansari</dc:creator>
	<dc:creator>Eddy Prianto</dc:creator>
	<dc:creator>Agung Dwiyanto</dc:creator>
	<dc:subject xml:lang="en-US">Fly ash and Bottom ash bricks, Wall surface temperature, and field research</dc:subject>
	<dc:description xml:lang="en-US">The processing of coal waste into building materials from fly ash bottom ash has been stipulated in Regulation number 22 of 2021 as Non-Hazardous material, with a note that the management requirements must still meet the standards and technical requirements set out and listed in the environmental document approval. Previous&amp;nbsp;studiesstated that one of the physical characteristics of the use of this waste (fly ash bottom ash) can be in improving the quality of construction materials and environmental quality. The research questions of this study are: Does&amp;nbsp;the facing east orientation quantitatively receiving more&amp;nbsp;heat of the morning sun than other orientations? Does FABA brick walls affect the indoor thermal&amp;nbsp;performance? The wall surface temperature measurement is carried out by&amp;nbsp;the field&amp;nbsp;experimentation&amp;nbsp;with extreme climatic conditions, both&amp;nbsp;sunny and rainy weather in 2021. The&amp;nbsp;results of this study&amp;nbsp;found that the surface temperature profile of the brick wall oriented to the east in sunny rainy/cold weather is cooler 2 % compared to the temperature on the western side. The wall surface temperature profile in the morning is 25% warmer than the ambient air temperature in sunny weather and 9% cooler in rainy weather. wall material with FABA brick&amp;nbsp;proves that the orientation, location and character of the microclimate are significant to the thermal value.</dc:description>
	<dc:publisher xml:lang="en-US">Unit Publikasi Ilmiah, P3M, Politeknik Negeri Bali</dc:publisher>
	<dc:date>2022-07-30</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ojs2.pnb.ac.id/index.php/LOGIC/article/view/422</dc:identifier>
	<dc:identifier>10.31940/logic.v22i2.198-208</dc:identifier>
	<dc:source xml:lang="en-US"> Logic : Jurnal Rancang Bangun dan Teknologi; Vol. 22 No. 2 (2022): July; 190-200</dc:source>
	<dc:source>2580-5649</dc:source>
	<dc:source>1412-114X</dc:source>
	<dc:source>10.31940/logic.v22i2</dc:source>