Journal
SINTA 3
Water Conditioning Refrigeration System Design and Construction for Lobster Cultivation
Logic: Jurnal Rancang Bangun dan Teknologi · Vol. 23 No. 1 (2023) · pp. 1–7
ISSN 2580-5649, 1412-114X
Published 2023-03-30
Publisher Unit Publikasi Ilmiah, P3M, Politeknik Negeri Bali
Language eng
Abstract
This research is to determine the cooling burden of the water conditioning system for lobster conditioning, where water must be conditioned to its temperature by its 21°C conditioning. This device uses steam compression systems precisely by utilizing water conditioning systems to condition water to stay awake at a temperature of 21°C. The method used in this study was to determine the volume of the water tank and its cooling capacity by calculating the load load and calculating the heat load through the walls of the water tank and other heat generated. For lobster cultivation, an air conditioning machine with a capacity of 1/2 PK. From the results of testing the tool for 3 hours, the results of system performance at an evaporation temperature of 15.2 °C and a product temperature of 21 °C obtained a Carnot COP of 7.11, an actual COP of 5.87, and an efficiency of 82.55%. This is in accordance with Design Carnot COP 8, actual COP design of 6.7, and design efficiency of 83%.
Collaboration network of the authors
7 authors ·
13 co-authorship links
Hover or tap a name to highlight its co-authors. Double-click to open the author's page.
Politeknik Negeri Indramayu Affiliation unknown
Different organisations
Same organisation
Affiliation unknown
Thicker line = more joint articles · bigger circle = more articles
Show as table
Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.
Metadata source: OAI-PMH (metadata jurnal) https://ojs2.pnb.ac.id/index.php/LOGIC/oai, first harvested 19 Nov 2026, last seen 19 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">Water Conditioning Refrigeration System Design and Construction for Lobster Cultivation</dc:title>
<dc:creator>Wardika</dc:creator>
<dc:creator>Yudhy Kurniawan</dc:creator>
<dc:creator>Hadi Prayitno</dc:creator>
<dc:creator>Sintya Haula H.</dc:creator>
<dc:subject xml:lang="en-US">Cooling Load</dc:subject>
<dc:subject xml:lang="en-US">COP</dc:subject>
<dc:subject xml:lang="en-US">Efficiency</dc:subject>
<dc:subject xml:lang="en-US">Refrigeration</dc:subject>
<dc:subject xml:lang="en-US">Lobster</dc:subject>
<dc:description xml:lang="en-US">This research is to determine the cooling burden of the water conditioning system for lobster conditioning, where water must be conditioned to its temperature by its 21°C conditioning. This device uses steam compression systems precisely by utilizing water conditioning systems to condition water to stay awake at a temperature of 21°C.&nbsp;The method used in this study was to determine the volume of the water tank and its cooling capacity by calculating the load load and calculating the heat load through the walls of the water tank and other heat generated. For lobster cultivation, an air conditioning machine with a capacity of 1/2 PK. From the results of testing the tool for 3 hours, the results of system performance at an evaporation temperature of 15.2 °C and a product temperature of 21 °C obtained a Carnot COP of 7.11, an actual COP of 5.87, and an efficiency of 82.55%. This is in accordance with Design Carnot COP 8, actual COP design of 6.7, and design efficiency of 83%.</dc:description>
<dc:publisher xml:lang="en-US">Unit Publikasi Ilmiah, P3M, Politeknik Negeri Bali</dc:publisher>
<dc:date>2023-03-30</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://ojs2.pnb.ac.id/index.php/LOGIC/article/view/725</dc:identifier>
<dc:identifier>10.31940/logic.v23i1.1-7</dc:identifier>
<dc:source xml:lang="en-US"> Logic : Jurnal Rancang Bangun dan Teknologi; Vol. 23 No. 1 (2023): March; 1-7</dc:source>
<dc:source>2580-5649</dc:source>
<dc:source>1412-114X</dc:source>
<dc:source>10.31940/logic.v23i1</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://ojs2.pnb.ac.id/index.php/LOGIC/article/view/725/518</dc:relation>
<dc:rights xml:lang="en-US">Copyright (c) 2023 Logic : Jurnal Rancang Bangun dan Teknologi</dc:rights>
<dc:rights xml:lang="en-US">https://scholar.google.co.id/citations?user=smBuD3gAAAAJ&hl=id</dc:rights>
</oai_dc:dc>
Citations and indexing
OpenAlex
Indexed
via DOI
1 citation
Crossref
Indexed
via DOI
0 citations
Counts as reported by each index on 19 Nov 2026; indexes count citations differently.
OpenAlex also lists this work in: crossref, doaj.
Cite this article
APA 7
Wardika, Kurniawan, Y., Prayitno, H., & H., S. H. (2023). Water Conditioning Refrigeration System Design and Construction for Lobster Cultivation. Logic: Jurnal Rancang Bangun dan Teknologi, 23(1), 1–7. https://doi.org/10.31940/logic.v23i1.1-7
Copy
IEEE
Wardika, Y. Kurniawan, H. Prayitno, and S. H. H., “Water Conditioning Refrigeration System Design and Construction for Lobster Cultivation,” Logic: Jurnal Rancang Bangun dan Teknologi, vol. 23, no. 1, pp. 1–7, 2023, doi: 10.31940/logic.v23i1.1-7.
Copy
Generated from the journal's metadata; check author names before use.