Melola Discovery

← Melola Discovery

Journal SINTA 3

Analysis of the Selection and Installation of a Pump for an Overflow Swimming Pool with a Volume of 67 Cubic Meters

Logic: Jurnal Rancang Bangun dan Teknologi · Vol. 23 No. 2 (2023) · pp. 138–146

DOI
10.31940/logic.v23i2.138-146
ISSN
2580-5649, 1412-114X
Published
2023-07-31
Publisher
Unit Publikasi Ilmiah, P3M, Politeknik Negeri Bali
Language
eng

Abstract

In the swimming pool there is a pump system that is useful for circulating water. Pumps in swimming pools can affect water quality. Dirty water will be cleaned by the filter and will be re-circulated to the swimming pool. The calculations that must be known are the volume of the swimming pool, pump power, flow rate, and the curve of the pump. In order for the selection of a swimming pool pump to be appropriate, the correct calculation must be made so that the pump can provide the best performance for a swimming pool with a volume of 67 cubic meters and is able to circulate swimming pool water 4 times during 12 working hours.

Keywords

Collaboration network of the authors

40 authors · 121 co-authorship links · showing the 40 most connected

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Politeknik Negeri Bali
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
I Wayan Suma WibawaPoliteknik Negeri Bali4
I Nyoman SutarnaPoliteknik Negeri Bali4
I Nengah Ludra AntaraPoliteknik Negeri Bali4
I Made RajendraPoliteknik Negeri Bali2
I Wayan SuiryaPoliteknik Negeri Bali2
I Wayan Adi SubagiaPoliteknik Negeri Bali2
I Nyoman SuamirPoliteknik Negeri Bali2
I Nyoman BudiarthanaAffiliation unknown2
I Nengah Darma SusilaAffiliation unknown2
. SudirmanAffiliation unknown2
I Nyoman Gede BaliartaPoliteknik Negeri Bali2
I Wayan TemajaPoliteknik Negeri Bali1
Ida Bagus Gde WidiantaraPoliteknik Negeri Bali1
Made Ery ArsanaPoliteknik Negeri Bali1
M. YusufPoliteknik Negeri Bali1
I Made SudanaPoliteknik Negeri Bali1
NK Dessy HariyantiAffiliation unknown1
IGN Suta WaisnawaAffiliation unknown1
IA Dwita Krisna AriAffiliation unknown1
Ni Kadek Dessy HariyantiAffiliation unknown1
Risa Nurin BaitiPoliteknik Negeri Bali1
I Komang KantunPoliteknik Negeri Bali1
I Nyoman SupartaPoliteknik Negeri Bali1
I Wayan Marlon ManagiPoliteknik Negeri Bali1
Anak Agung Gede Pradnyana DiputraPoliteknik Negeri Bali1
Made Ardikosa Satrya WibawaAffiliation unknown1
I Made Anom AdiaksaPoliteknik Negeri Bali1
I Made Agus PutrawanPoliteknik Negeri Bali1
I Putu Eka IdrayanaPoliteknik Negeri Bali1
Anak Agung Ngurah Dwi Indra PutraPoliteknik Negeri Bali1
Ketut BangsePoliteknik Negeri Bali1
I Made Anom AdiaksaPoliteknik Negeri Bali1
I Nengah Ludra AntaraAffiliation unknown1
I Wayan SuwiryaPoliteknik Negeri Bali1
Ni Wayan Merda Surya DewiPoliteknik Negeri Bali1
I Gusti Bagus Wijaya KusumaAffiliation unknown1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OAI-PMH (metadata jurnal) https://ojs2.pnb.ac.id/index.php/LOGIC/oai, first harvested 19 Nov 2026, last seen 19 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Analysis of the Selection and Installation of a Pump for an Overflow Swimming Pool with a Volume of 67 Cubic Meters</dc:title>
	<dc:creator>Achmad Wibolo</dc:creator>
	<dc:creator>I Ketut Suherman</dc:creator>
	<dc:creator>I Dewa Made Pancarana</dc:creator>
	<dc:creator>I Ketut Adi</dc:creator>
	<dc:subject xml:lang="en-US">power</dc:subject>
	<dc:subject xml:lang="en-US">pump</dc:subject>
	<dc:subject xml:lang="en-US">flowrate</dc:subject>
	<dc:subject xml:lang="en-US">swimming pool</dc:subject>
	<dc:description xml:lang="en-US">In the swimming pool there is a pump system that is useful for circulating water. Pumps  in  swimming pools can affect water quality. Dirty  water will be cleaned by the  filter  and  will  be re-circulated to the swimming pool. The calculations  that  must  be  known  are  the  volume  of  the swimming  pool,  pump  power, flow rate, and the curve of  the pump. In  order  for  the  selection of a swimming  pool pump  to be  appropriate, the  correct  calculation  must  be made  so that the pump  can provide  the best  performance for a swimming pool with a volume of 67 cubic meters  and is able to circulate swimming pool water 4 times  during 12 working hours.</dc:description>
	<dc:publisher xml:lang="en-US">Unit Publikasi Ilmiah, P3M, Politeknik Negeri Bali</dc:publisher>
	<dc:date>2023-07-31</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ojs2.pnb.ac.id/index.php/LOGIC/article/view/1090</dc:identifier>
	<dc:identifier>10.31940/logic.v23i2.138-146</dc:identifier>
	<dc:source xml:lang="en-US"> Logic : Jurnal Rancang Bangun dan Teknologi; Vol. 23 No. 2 (2023): July; 138-146</dc:source>
	<dc:source>2580-5649</dc:source>
	<dc:source>1412-114X</dc:source>
	<dc:source>10.31940/logic.v23i2</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ojs2.pnb.ac.id/index.php/LOGIC/article/view/1090/646</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2023  Logic : Jurnal Rancang Bangun dan Teknologi</dc:rights>
	<dc:rights xml:lang="en-US">https://scholar.google.co.id/citations?user=smBuD3gAAAAJ&amp;hl=id</dc:rights>
</oai_dc:dc>