Melola Discovery

← Melola Discovery

Journal SINTA 3

Design of Clean Water Booster Pump for High-Rise Buildings

Logic: Jurnal Rancang Bangun dan Teknologi · Vol. 23 No. 3 (2023) · pp. 203–211

DOI
10.31940/logic.v23i3.203-211
ISSN
2580-5649, 1412-114X
Published
2023-11-30
Publisher
Unit Publikasi Ilmiah, P3M, Politeknik Negeri Bali
Language
eng

Abstract

A sanitary system is a supporting component designed to meet the clean water requirements of a building, primarily for sanitation activities. The average sanitary equipment used typically requires a shower pressure of ±1 Bar. However, the shower pressure can be significantly affected by factors such as the distance from the top tank and the building's layout, considering only the pressure due to gravity. To address inadequate shower pressure, an auxiliary pump known as a booster pump is necessary. The need for a booster pump is determined by the cumulative demand from plumbing equipment, where the total capacity required is 6057 liters/hour. To address this demand, the system employs two pump units, each with a capacity of 3 m3/hour. The distribution pipes utilized in the system adhere to established standards and are made of random polypropylene with a diameter of 2 inches and a flow rate of 0.005889 m3/second. The overall head loss resulting from this installation amounts to 31.62 meters. To accommodate the booster system, a pressure tank with a capacity of 67 liters is employed. The minimum working pressure required for the pumps is 1.8 Bar.

Keywords

Collaboration network of the authors

40 authors · 116 co-authorship links · 4 across different organisations · showing the 40 most connected

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Politeknik Negeri Bali
  • Warmadewa University
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
I Kadek DwianaPoliteknik Negeri Bali3
I Nengah Ludra AntaraPoliteknik Negeri Bali3
I Nyoman SutarnaPoliteknik Negeri Bali3
I Nyoman SuamirPoliteknik Negeri Bali3
I Wayan Adi SubagiaPoliteknik Negeri Bali2
I Putu Merta AdnyanaPoliteknik Negeri Bali2
Ida Bagus Puspa IndraPoliteknik Negeri Bali2
I Wayan Adi SubagiaPoliteknik Negeri Bali2
I Dewa Made SusilaPoliteknik Negeri Bali2
I Ketut RimpungPoliteknik Negeri Bali2
I Wayan TemajaPoliteknik Negeri Bali2
I Putu DarmawaPoliteknik Negeri Bali2
I Komang RusmariadiPoliteknik Negeri Bali2
Made Ery ArsanaPoliteknik Negeri Bali1
Arbyansyah DarmawanPoliteknik Negeri Bali1
I Dewa Gede Agus Tri PutraAffiliation unknown1
I Gede Artha NegaraPoliteknik Negeri Bali1
Daud Simon AnakottaparyPoliteknik Negeri Bali1
Edo KriswidiantoAffiliation unknown1
I Wayan TemajaAffiliation unknown1
I Wayan Agus Rantia DanaPoliteknik Negeri Bali1
I Made Bagus Panji AdityaPoliteknik Negeri Bali1
I Komang Risky Putra WibawaAffiliation unknown1
I Made Prasana YogaPoliteknik Negeri Bali1
I Nengah Darma SusilaAffiliation unknown1
I Made SuartaAffiliation unknown1
I Putu Gede Sopan RahtikaAffiliation unknown1
Putu Wijaya SunuAffiliation unknown1
Achmad WiboloPoliteknik Negeri Bali1
I Putu Gede Sopan RahtikaPoliteknik Negeri Bali1
Anak Agung Ngurah Bagus MulawarmanPoliteknik Negeri Bali1
I N. G. SastrawanPoliteknik Negeri Bali1
Bagus RadityaPoliteknik Negeri Bali1
I Ketut SuparwikaPoliteknik Negeri Bali1
I Putu Sandi RadityaPoliteknik Negeri Bali1
Kadek Agus Mahabojana D.P.Warmadewa University1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OAI-PMH (metadata jurnal) https://ojs2.pnb.ac.id/index.php/LOGIC/oai, first harvested 19 Nov 2026, last seen 19 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Design of Clean Water Booster Pump for High-Rise Buildings</dc:title>
	<dc:creator>Luh Putu Ike Midiani</dc:creator>
	<dc:creator>I Made Duta Irawan</dc:creator>
	<dc:creator>Bangse, Ketut</dc:creator>
	<dc:creator>Gunung, I Nyoman</dc:creator>
	<dc:subject xml:lang="en-US">booster pump</dc:subject>
	<dc:subject xml:lang="en-US">clean water</dc:subject>
	<dc:subject xml:lang="en-US">high-rise building</dc:subject>
	<dc:description xml:lang="en-US">A sanitary system is a supporting component designed to meet the clean water requirements of a building, primarily for sanitation activities. The average sanitary equipment used typically requires a shower pressure of ±1 Bar. However, the shower pressure can be significantly affected by factors such as the distance from the top tank and the building's layout, considering only the pressure due to gravity. To address inadequate shower pressure, an auxiliary pump known as a booster pump is necessary. The need for a booster pump is determined by the cumulative demand from plumbing equipment, where the total capacity required is 6057 liters/hour. To address this demand, the system employs two pump units, each with a capacity of 3 m3/hour. The distribution pipes utilized in the system adhere to established standards and are made of random polypropylene with a diameter of 2 inches and a flow rate of 0.005889 m3/second. The overall head loss resulting from this installation amounts to 31.62 meters. To accommodate the booster system, a pressure tank with a capacity of 67 liters is employed. The minimum working pressure required for the pumps is 1.8 Bar.</dc:description>
	<dc:publisher xml:lang="en-US">Unit Publikasi Ilmiah, P3M, Politeknik Negeri Bali</dc:publisher>
	<dc:date>2023-11-30</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ojs2.pnb.ac.id/index.php/LOGIC/article/view/1294</dc:identifier>
	<dc:identifier>10.31940/logic.v23i3.203-211</dc:identifier>
	<dc:source xml:lang="en-US"> Logic : Jurnal Rancang Bangun dan Teknologi; Vol. 23 No. 3 (2023): November; 203-211</dc:source>
	<dc:source>2580-5649</dc:source>
	<dc:source>1412-114X</dc:source>
	<dc:source>10.31940/logic.v23i3</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ojs2.pnb.ac.id/index.php/LOGIC/article/view/1294/700</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2023  Logic : Jurnal Rancang Bangun dan Teknologi</dc:rights>
	<dc:rights xml:lang="en-US">https://scholar.google.co.id/citations?user=smBuD3gAAAAJ&amp;hl=id</dc:rights>
</oai_dc:dc>