Journal
SINTA 3
The Effect of Injection Pressure and Injection Temperature in The Compression Moulding Process on Flashing Defects of Shoulder Products
Logic: Jurnal Rancang Bangun dan Teknologi · Vol. 25 No. 1 (2025) · pp. 13–18
ISSN 2580-5649, 1412-114X
Published 2025-03-30
Publisher Unit Publikasi Ilmiah, P3M, Politeknik Negeri Bali
Language eng
Abstract
Plastic objects are everywhere: toys, household utensils, playthings, and cosmetic containers. One of the processes used was the plastic production process in the compression molding process to make a cover (shoulder) on the tube. Flashing defects are one of the biggest defects that can cause a product to fail in the assembly of shoulder extrusion tube products in PT. XYZ. This research was to determine the effect of injection pressure and injection temperature parameters on flashing defects in shoulder extrusion tube products. This research uses quantitative research and experimental research methods to collect data. Varying parameter settings carry out this method with an injection pressure of 4 bar, 5 bar, and 6 bar as well as injection temperatures of 250°C, 260°C, and 270°C. The results of the study show that both parameters have significant effects on the flashing defects in shoulder extrusion tube products. The combination of injection pressure of 4 bar and injection temperature of 250°C resulting in flashing defects of 0 mm or no defects.
Collaboration network of the authors
15 authors ·
39 co-authorship links
· 16 across different organisations
Hover or tap a name to highlight its co-authors. Double-click to open the author's page.
Politeknik Negeri Malang Universitas Sebelas Maret Kumamoto University Universitas Negeri Padang
Different organisations
Same organisation
Affiliation unknown
Thicker line = more joint articles · bigger circle = more articles
Show as table
Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.
Metadata source: OAI-PMH (metadata jurnal) https://ojs2.pnb.ac.id/index.php/LOGIC/oai, first harvested 19 Nov 2026, last seen 19 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">The Effect of Injection Pressure and Injection Temperature in The Compression Moulding Process on Flashing Defects of Shoulder Products</dc:title>
<dc:creator>Hartono, Moh</dc:creator>
<dc:creator>Pratama, Febrian Akbar</dc:creator>
<dc:subject xml:lang="en-US">Flashing Defect</dc:subject>
<dc:subject xml:lang="en-US">Shoulder Extrusion Tube</dc:subject>
<dc:subject xml:lang="en-US">Compression Moulding</dc:subject>
<dc:subject xml:lang="en-US">Injection Pressure</dc:subject>
<dc:subject xml:lang="en-US">Injection Temperature</dc:subject>
<dc:description xml:lang="en-US">Plastic objects are everywhere: toys, household utensils, playthings, and cosmetic containers. One of the processes used was the plastic production process in the compression molding process to make a cover (shoulder) on the tube. Flashing defects are one of the biggest defects that can cause a product to fail in the assembly of shoulder extrusion tube products in PT. XYZ. This research was to determine the effect of injection pressure and injection temperature parameters on flashing defects in shoulder extrusion tube products. This research uses quantitative research and experimental research methods to collect data. Varying parameter settings carry out this method with an injection pressure of 4 bar, 5 bar, and 6 bar as well as injection temperatures of 250°C, 260°C, and 270°C. The results of the study show that both parameters have significant effects on the flashing defects in shoulder extrusion tube products. The combination of injection pressure of 4 bar and injection temperature of 250°C resulting in flashing defects of 0 mm or no defects.</dc:description>
<dc:publisher xml:lang="en-US">Unit Publikasi Ilmiah, P3M, Politeknik Negeri Bali</dc:publisher>
<dc:date>2025-03-30</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://ojs2.pnb.ac.id/index.php/LOGIC/article/view/2070</dc:identifier>
<dc:identifier>10.31940/logic.v25i1.13-18</dc:identifier>
<dc:source xml:lang="en-US"> Logic : Jurnal Rancang Bangun dan Teknologi; Vol. 25 No. 1 (2025): March; 13-18</dc:source>
<dc:source>2580-5649</dc:source>
<dc:source>1412-114X</dc:source>
<dc:source>10.31940/logic.v25i1</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://ojs2.pnb.ac.id/index.php/LOGIC/article/view/2070/1096</dc:relation>
<dc:rights xml:lang="en-US">Copyright (c) 2025 Logic : Jurnal Rancang Bangun dan Teknologi</dc:rights>
<dc:rights xml:lang="en-US">https://scholar.google.co.id/citations?user=smBuD3gAAAAJ&hl=id</dc:rights>
</oai_dc:dc>
Citations and indexing
OpenAlex
Indexed
via DOI
1 citation
Crossref
Indexed
via DOI
0 citations
Counts as reported by each index on 19 Nov 2026; indexes count citations differently.
OpenAlex also lists this work in: crossref, doaj.
Cite this article
APA 7
Hartono, M., & Pratama, F. A. (2025). The Effect of Injection Pressure and Injection Temperature in The Compression Moulding Process on Flashing Defects of Shoulder Products. Logic: Jurnal Rancang Bangun dan Teknologi, 25(1), 13–18. https://doi.org/10.31940/logic.v25i1.13-18
Copy
IEEE
M. Hartono and F. A. Pratama, “The Effect of Injection Pressure and Injection Temperature in The Compression Moulding Process on Flashing Defects of Shoulder Products,” Logic: Jurnal Rancang Bangun dan Teknologi, vol. 25, no. 1, pp. 13–18, 2025, doi: 10.31940/logic.v25i1.13-18.
Copy
Generated from the journal's metadata; check author names before use.