Melola Discovery

← Melola Discovery

Journal SINTA 3

Performance Analysis of Thermoelectric Cooler Box with Water Cooling Block (WCB) and Heat Sink Fan

Logic: Jurnal Rancang Bangun dan Teknologi · Vol. 25 No. 2 (2025) · pp. 93–99

DOI
10.31940/logic.v25i2.93-99
ISSN
2580-5649, 1412-114X
Published
2025-07-27
Publisher
Unit Publikasi Ilmiah, P3M, Politeknik Negeri Bali
Language
eng

Abstract

Thermoelectric cooler boxes offer an environmentally friendly, energy-efficient, and portable cooling solution. However, the performance of thermoelectric cooling systems is highly dependent on the effectiveness of heat dissipation on the hot side of the Peltier module (TEC). This study aims to experimentally investigate the impact of using a Water Cooling Block (WCB) compared to a conventional heat sink fan on the cooling performance of a thermoelectric-based cooler box. The experimental setup involved two configurations for the hot side cooling system, where parameters such as hot-side temperature, cabin temperature, and Coefficient of Performance (COP) were measured and analyzed. The experimental results showed that the use of WCB was able to significantly reduce the temperature on the hot side, with a temperature reduction in the cabin reaching 20.35 °C and an average COP of 0.09687. Meanwhile, the TEC-fan temperature in the cabin cooler box was lower at 21.45 °C, with an average COP value of 0.04718. Therefore, the Water Cooling Block demonstrates superior efficiency and thermal management compared to the heat sink fan, offering enhanced performance for thermoelectric cooler box applications in various low-temperature storage needs.

Keywords

Collaboration network of the authors

36 authors · 121 co-authorship links · 10 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Politeknik Negeri Bali
  • Universitas Pembangunan Nasional Veteran Jakarta
  • Muhammadiyah University of Surakarta
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
James JulianUniversitas Pembangunan Nasional Veteran Jakarta3
I Made RastaAffiliation unknown3
I Nyoman SuamirAffiliation unknown3
Fitri WahyuniUniversitas Pembangunan Nasional Veteran Jakarta2
I Wayan Adi SubagiaPoliteknik Negeri Bali2
Riki Hendra PurbaUniversitas Pembangunan Nasional Veteran Jakarta2
Elvi ErmadaniUniversitas Pembangunan Nasional Veteran Jakarta2
Made Ery ArsanaPoliteknik Negeri Bali2
I Dewa Made Cipta SantosaPoliteknik Negeri Bali2
I Gusti Agung Bagus WirajatiPoliteknik Negeri Bali2
I Nyoman Agus Adi SaputraPoliteknik Negeri Bali2
Annastya Bagas DewantaraUniversitas Pembangunan Nasional Veteran Jakarta1
Nandy PutraAffiliation unknown1
I Gusti Ketut PujaAffiliation unknown1
Ngafwan NgafwanMuhammadiyah University of Surakarta1
I Wayan TemajaPoliteknik Negeri Bali1
Ida Ayu Anom ArsaniPoliteknik Negeri Bali1
I Gede Artha NegaraPoliteknik Negeri Bali1
I Nyoman Gede BaliartaPoliteknik Negeri Bali1
Komang Widhi WidanthaPoliteknik Negeri Bali1
Luh Putu Ike MidianiAffiliation unknown1
I Gusti Agung Oka SudiadnyaniAffiliation unknown1
I Dewa Made SusilaPoliteknik Negeri Bali1
I Wayan SuiryaPoliteknik Negeri Bali1
I Made RastaPoliteknik Negeri Bali1
I Gusti Ketut PujaPoliteknik Negeri Bali1
Putu Wijaya SunuPoliteknik Negeri Bali1
Anggie Topan WijayaUniversitas Pembangunan Nasional Veteran Jakarta1
Fathin MadhudhuAffiliation unknown1
Fathin Muhammad MahdhudhuUniversitas Pembangunan Nasional Veteran Jakarta1
Bima Rakha AdhitamaUniversitas Pembangunan Nasional Veteran Jakarta1
Fitri WahyuniUniversitas Pembangunan Nasional Veteran Jakarta1
DaudSimon AnnakotaparyAffiliation unknown1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OAI-PMH (metadata jurnal) https://ojs2.pnb.ac.id/index.php/LOGIC/oai, first harvested 19 Nov 2026, last seen 19 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Performance Analysis of Thermoelectric Cooler Box with Water Cooling Block (WCB) and Heat Sink Fan</dc:title>
	<dc:creator>Sutina, I Wayan</dc:creator>
	<dc:creator>Winarta, Adi</dc:creator>
	<dc:creator>Saputra, I Nyoman Agus Adi</dc:creator>
	<dc:subject xml:lang="en-US">Thermoelectric</dc:subject>
	<dc:subject xml:lang="en-US">Cooler box</dc:subject>
	<dc:subject xml:lang="en-US">Water cooling block</dc:subject>
	<dc:subject xml:lang="en-US">Heat sink fan</dc:subject>
	<dc:subject xml:lang="en-US">COP</dc:subject>
	<dc:subject xml:lang="en-US">Peltier module</dc:subject>
	<dc:description xml:lang="en-US">Thermoelectric cooler boxes offer an environmentally friendly, energy-efficient, and portable cooling solution. However, the performance of thermoelectric cooling systems is highly dependent on the effectiveness of heat dissipation on the hot side of the Peltier module (TEC). This study aims to experimentally investigate the impact of using a Water Cooling Block (WCB) compared to a conventional heat sink fan on the cooling performance of a thermoelectric-based cooler box. The experimental setup involved two configurations for the hot side cooling system, where parameters such as hot-side temperature, cabin temperature, and Coefficient of Performance (COP) were measured and analyzed. The experimental results showed that the use of WCB was able to significantly reduce the temperature on the hot side, with a temperature reduction in the cabin reaching 20.35 °C and an average COP of 0.09687. Meanwhile, the TEC-fan temperature in the cabin cooler box was lower at 21.45 °C, with an average COP value of 0.04718. Therefore, the Water Cooling Block demonstrates superior efficiency and thermal management compared to the heat sink fan, offering enhanced performance for thermoelectric cooler box applications in various low-temperature storage needs.</dc:description>
	<dc:publisher xml:lang="en-US">Unit Publikasi Ilmiah, P3M, Politeknik Negeri Bali</dc:publisher>
	<dc:date>2025-07-27</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ojs2.pnb.ac.id/index.php/LOGIC/article/view/2618</dc:identifier>
	<dc:identifier>10.31940/logic.v25i2.93-99</dc:identifier>
	<dc:source xml:lang="en-US"> Logic : Jurnal Rancang Bangun dan Teknologi; Vol. 25 No. 2 (2025): July; 93-99</dc:source>
	<dc:source>2580-5649</dc:source>
	<dc:source>1412-114X</dc:source>
	<dc:source>10.31940/logic.v25i2</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ojs2.pnb.ac.id/index.php/LOGIC/article/view/2618/1163</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2025  Logic : Jurnal Rancang Bangun dan Teknologi</dc:rights>
	<dc:rights xml:lang="en-US">https://scholar.google.co.id/citations?user=smBuD3gAAAAJ&amp;hl=id</dc:rights>
</oai_dc:dc>