High-rise buildings are at risk of collapse due to the earthquake. One method for analyzing earthquake loads is Pushover. Pushover is a non-linear static analysis to determine the behavior of a building collapse. This research was conducted to determine the performance of the setback building with a soft first story due to the earthquake based on the results of the pushover analysis curve. The structure is modeled as a 2-dimensional portal with a form of structural irregularity (setback with the soft first story) which consists of 2 structural models with different setback area ratios. The results of the analysis of this study indicate that the maximum shear force based on capacity curves in type 1 and type 2 buildings are 50260549.81 N and 53560488.63 N. Buildings with smaller setback area ratios, i.e., type 2 buildings have displacement, story drift, and base shear are more significant than type 1 buildings. Performance of type 1 and Type 2 building structures that refer to ATC-40 and FEMA 356 is at the Damage Control level.

Collaboration network of the authors

11 authors · 20 co-authorship links

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Jakarta State Polytechnic
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Jonathan SaputraJakarta State Polytechnic4
I Ketut SucitaJakarta State Polytechnic2
Jasun Widiana PutraJakarta State Polytechnic1
Hanif Satria AjiJakarta State Polytechnic1
Oky Bima PutraJakarta State Polytechnic1
Ilham Dwiputra RamadhanJakarta State Polytechnic1
Tree Irma DindaJakarta State Polytechnic1
Nadhila Ramadhani A.P.Jakarta State Polytechnic1
Annisaa Dina PuspitaJakarta State Polytechnic1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OAI-PMH (metadata jurnal) https://ojs.pnb.ac.id/index.php/LOGIC/oai, first harvested 19 Nov 2026, last seen 19 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">The Performance of Irregular Building   Structures Using Pushover Analysis</dc:title>
	<dc:creator>Yurizka, Hanan</dc:creator>
	<dc:creator>Rosyidah, Anis</dc:creator>
	<dc:description xml:lang="en-US">High-rise buildings are at risk of collapse due to the earthquake. One method for analyzing earthquake loads is Pushover. Pushover is a non-linear static analysis to determine the behavior of a building collapse. This research was conducted to determine the performance of the setback building with a soft first story due to the earthquake based on the results of the pushover analysis curve. The structure is modeled as a 2-dimensional portal with a form of structural irregularity (setback with the soft first story) which consists of 2 structural models with different setback area ratios. The results of the analysis of this study indicate that the maximum shear force based on capacity curves in type 1 and type 2 buildings are 50260549.81 N and 53560488.63 N. Buildings with smaller setback area ratios, i.e., type 2 buildings have displacement, story drift, and base shear are more significant than type 1 buildings. Performance of type 1 and Type 2 building structures that refer to ATC-40 and FEMA 356 is at the Damage Control level.</dc:description>
	<dc:publisher xml:lang="en-US">Pusat Penelitian dan Pengabdian kepada Masyarakat (P3M) Politeknik Negeri Bali</dc:publisher>
	<dc:date>2020-07-30</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ojs.pnb.ac.id/index.php/LOGIC/article/view/1456</dc:identifier>
	<dc:identifier>10.31940/logic.v20i2.1456</dc:identifier>
	<dc:source xml:lang="en-US">Logic : Jurnal Rancang Bangun dan Teknologi; Vol 20 No 2 (2020): July; 65-72</dc:source>
	<dc:source>2580-5649</dc:source>
	<dc:source>1412-114X</dc:source>
	<dc:source>10.31940/logic.v20i2</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ojs.pnb.ac.id/index.php/LOGIC/article/view/1456/1437</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2020 Logic : Jurnal Rancang Bangun dan Teknologi</dc:rights>
</oai_dc:dc>